The freedom SOLO valve: Superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement

被引:0
|
作者
Beholz, Sven [1 ]
Dushe, Simon [1 ]
Konertz, Wolfgang [1 ]
机构
[1] Univ Med Berlin, Charite, Dept Cardiovasc Surg, D-10117 Berlin, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2007年 / 16卷 / 01期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The new Freedom SOLO aortic valve, as a modification of the Pericarbon (TM) Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. Methods: In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation. Results: The mean extracorporeal circulation time (75.5 +/- 22.7 min in FS; 83.7 +/- 21.0 min in PFC versus 110.9 +/- 31.4 min in PFI) and cross-clamp time (56.0 +/- 18.6 min in FS; 62.2 +/- 16.2 min in PFC versus 87.7 +/- 25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4 +/- 4.6 mmHg in FS versus 10.6 +/- 6.0 mmHg in PFC and 11.0 +/- 5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations. Conclusion: The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 50 条
  • [21] Results of Biocor stentless valve replacement for infective endocarditis of the native aortic valve
    Santini, F
    Bertolini, P
    Vecchi, B
    Borghetti, V
    Mazzucco, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (09): : 1136 - +
  • [22] Freedom Solo Stentless Aortic Valve: Quantitative and Qualitative Assessment of Thrombocytopenia
    Tarzia, Vincenzo
    Bottio, Tomaso
    Buratto, Edward
    Spiezia, Luca
    Simioni, Paolo
    Gerosa, Gino
    ANNALS OF THORACIC SURGERY, 2011, 92 (05): : 1935 - 1935
  • [23] Own experience with implantation of new stentless valve Freedom SOLO®
    Pawlak, Szymon
    Niklewski, Tomasz
    Sliwka, Joanna
    Foremny, Jerzy
    Zembala, Marian
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2011, 8 (01): : 52 - 56
  • [24] Pericarbon pericardial valve prosthesis: Midterm results of the aortic valve replacement
    Borowiec, JW
    Dubiel, TW
    Hansson, HE
    Landelius, J
    Nystrom, SO
    ANGIOLOGY, 1998, 49 (01) : 1 - 11
  • [25] Hemodynamic evaluation of a new stentless autologous pericardial mitral valve
    Shomura, Y
    Tahta, SA
    Lansac, E
    Duran, CMG
    ANNALS OF THORACIC SURGERY, 2001, 71 (05): : S315 - S317
  • [26] Short-term hemodynamic performance of the Sorin freedom SOLO stentless valve
    Da Col, Uberto
    Di Bella, Isidoro
    Bardelli, Giuliana
    Ramoni, Enrico
    Affronti, Alessandro
    Vidili, Angela
    Ragni, Temistocle
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (05): : 546 - 550
  • [27] Stentless pericardial valve for acute aortic valve endocarditis with annular destruction
    Pfeiffer, Steffen
    Santarpino, Giuseppe
    Fischlein, Theodor
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2015, 16 (04) : 318 - 319
  • [28] The Sorin Freedom SOLO stentless aortic valve: Technique of implantation and operative results in 109 patients
    Aymard, Thierry
    Eckstein, Friedrich
    Englberger, Lars
    Stalder, Mario
    Kadner, Alexander
    Carrel, Thierry
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (03): : 775 - 777
  • [29] Stentless xenografts for aortic valve replacement
    Doty, JR
    Doty, DB
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (02) : 240 - 251