The freedom SOLO valve: Superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement

被引:0
|
作者
Beholz, Sven [1 ]
Dushe, Simon [1 ]
Konertz, Wolfgang [1 ]
机构
[1] Univ Med Berlin, Charite, Dept Cardiovasc Surg, D-10117 Berlin, Germany
来源
JOURNAL OF HEART VALVE DISEASE | 2007年 / 16卷 / 01期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: The new Freedom SOLO aortic valve, as a modification of the Pericarbon (TM) Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. Methods: In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacement (AVR) between 2001 and 2004. The Freedom SOLO valve was implanted in 30 patients using a supra-annular, subcoronary technique with one continuous subcoronary suture line (group FS). For comparison, the Pericarbon Freedom valve was implanted in 30 patients using an interrupted suture (group PFI), and in 30 patients using a continuous suture line at the inflow site (group PFC). Patient hemodynamics at discharge were investigated by monitoring echocardiographic peak and mean gradients, and regurgitation. Results: The mean extracorporeal circulation time (75.5 +/- 22.7 min in FS; 83.7 +/- 21.0 min in PFC versus 110.9 +/- 31.4 min in PFI) and cross-clamp time (56.0 +/- 18.6 min in FS; 62.2 +/- 16.2 min in PFC versus 87.7 +/- 25.4 min in PFI) were significantly shorter with the continuous implantation techniques. Hemodynamics were most favorable for the Freedom SOLO valve as compared to either implantation technique of the Pericarbon Freedom valve (mean gradient 7.4 +/- 4.6 mmHg in FS versus 10.6 +/- 6.0 mmHg in PFC and 11.0 +/- 5.7 mmHg in PFI). There were no paravalvular leakages or transvalvular regurgitations. Conclusion: The Freedom SOLO stentless valve is easy to implant and demonstrates superior early postoperative hemodynamics. Due to the reduced cross-clamp time, it also offers an attractive option in isolated and combined AVR.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 50 条
  • [1] The Freedom SOLO Valve: Mid-Term Clinical Results with a Stentless Pericardial Valve for Aortic Valve Replacement
    Horst, Michael
    Easo, Jerry
    Hoelzl, Philipp P. F.
    Eichstaedt, Harald C.
    Kronberg, Kay
    Nordmeyer, Peter
    Dapunt, Otto E.
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (06): : 704 - 710
  • [2] Aortic Valve Replacement with the Freedom Solo Stentless Valve: Nine Years Clinical and Hemodynamic Findings
    Sponga, Sandro
    Pavoni, Daisy
    Nucifora, Gaetano
    Daffara, Cristian
    Vendramin, Igor
    Mazzaro, Enzo
    Piani, Daniela
    Lutman, Cristina
    Livi, Ugolino
    CARDIOLOGY, 2014, 128 (02) : 186 - 186
  • [3] The Freedom SOLO bovine pericardial stentless valve
    Stanger, Olaf
    Tevaearai, Hendrik
    Carrel, Thierry
    RESEARCH REPORTS IN CLINICAL CARDIOLOGY, 2014, 5 : 349 - 361
  • [4] Pericardial Stentless Valve for Aortic Valve Replacement: Long-Term Results
    Repossini, Alberto
    Fischlein, Theodor
    Santarpino, Giuseppe
    Schaefer, Christina
    Claus, Benjamin
    Passaretti, Bruno
    Di Bacco, Lorenzo
    Giroletti, Laura
    Bisleri, Gianluigi
    Muneretto, Claudio
    Grubitzsch, Herko
    ANNALS OF THORACIC SURGERY, 2016, 102 (06): : 1956 - 1965
  • [5] The Sorin Freedom SOLO Stentless Tissue Valve Early Outcomes after Aortic Valve Replacement
    Altintas, Garip
    Diken, Adem Ilkay
    Hanedan, Onur
    Yurdakok, Okan
    Ozyalcin, Sertan
    Kucuker, Seref Alp
    Ozatik, Mehmet Ali
    TEXAS HEART INSTITUTE JOURNAL, 2013, 40 (01): : 50 - 55
  • [6] Aortic Valve Replacement With the Stentless Freedom SOLO Bioprosthesis: A Systematic Review
    Wollersheim, Laurens W.
    Li, Wilson W.
    Bouma, Berto J.
    Repossini, Alberto
    van der Meulen, Jan
    de Mol, Bas A.
    ANNALS OF THORACIC SURGERY, 2015, 100 (04): : 1496 - 1504
  • [7] The Freedom SOLO Valve for Aortic Valve Replacement: Clinical and Hemodynamic Results from a Prospective Multicenter Trial
    Beholz, Sven
    Repossini, Alberto
    Livi, Ugolino
    Schepens, Marc
    El Gabry, Mohamed
    Matschke, Klaus
    Trivedi, Uday
    Eckel, Lothar
    Dapunt, Otto
    Luis Zamorano, Jose
    JOURNAL OF HEART VALVE DISEASE, 2010, 19 (01): : 115 - 123
  • [8] Truly stentless autologous pericardial aortic valve replacement: An alternative to standard aortic valve replacement
    Chan, K. M. John
    Rahman-Haley, Shelley
    Mittal, Tarun K.
    Gavino, Jemyrr A.
    Dreyfus, Gilles D.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (01): : 276 - 283
  • [9] Unusual Complication after Aortic Valve Replacement with the Freedom™ Solo Stentless Bioprosthesis
    Celiento, Michele
    Scioti, Giovanni
    Pratali, Stefano
    Guarracino, Fabio
    Bortolotti, Uberto
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (05): : 604 - 606
  • [10] Hemodynamic Investigation of a Stentless Molded Pericardial Aortic Valve
    Leo, H. L.
    Lim, W. Q. Marcus
    Xiong, F. L.
    Yeo, J. H.
    5TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2012, 37 : 888 - +