Simulation on Evaporation and Motion of Atomized Droplets in Spray Dry Flue Gas Desulfurization Tower

被引:4
|
作者
Zhang Tengfei [1 ]
Tang Qiang [1 ]
Pu Chao [1 ]
Yan Yunfei [1 ]
机构
[1] Chongqing Univ, Key Lab Low Grade Energy Utilizat Technol & Syst, Minist Educ PRC, Chongqing 400044, Peoples R China
关键词
spray dry FGD; atomized droplets; swirling flow; penetration length; droplet evaporation; FIRED POWER-PLANTS; WATER SPRAY; INLET AIR; FLOW;
D O I
10.1007/s11630-022-1612-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The evaporation and motion of atomized droplets have an essential effect on the safe and efficient long-term operation of the desulphurization tower. Therefore, the two-phase flow model is established and solved by three-dimensional steady Reynolds-averaged Navier-Stokes equations; the droplets are tracked by Eulerian-Lagrangian method. The three factors, including inlet swirling flow of flue gas, initial droplet diameter, and inlet flue gas temperature, are analyzed to show the effects on the evaporation and motion of atomized droplets, respectively. The results show that the swirling flow of flue gas and initial droplet diameter dominate the penetration length of the atomized droplets and the mixing characteristic of droplets and flue gas. With the increase of droplet diameter, the length of droplet penetrating flue gas increases. When droplet diameter is 200 mu m and inlet swirl number is 0.35, droplets completely penetrate the core area. Therefore, this is the maximum initial droplet diameter at the inlet swirl number of 0.35. The droplets evaporation time of initial 150 mu m diameter is 85.5% longer than that of 50 mu m droplets (0.35 of inlet swirl number). Increasing the inlet flue gas temperature can enhance the heat transfer. When inlet flue gas temperature rises from 483 K to 523 K, the evaporation time decreases by 33.8%. The results can be used to guide the optimization of droplets spray evaporation under practical operating conditions in the desulfurization tower.
引用
收藏
页码:2252 / 2263
页数:12
相关论文
共 50 条
  • [31] Experimental Investigation on Flue Gas Desulfurization by Electrostatic Spray
    Wang Zhentao
    Luo Tiqian
    2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 3, PROCEEDINGS, 2009, : 44 - 47
  • [32] Modeling and simulation of the microstructure evolution of the gas-atomized alloy droplets during spray forming
    Zhao, JH
    Liu, DM
    Ye, HQ
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2003, 19 (05) : 398 - 402
  • [34] Evaporation and condensing augmentation of water droplets in flue gas
    Miliauskas, Gintautas
    Sinkunas, Stasys
    Miliauskas, Giedrius
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (5-6) : 1220 - 1230
  • [35] STRUCTURAL DESIGN AND NUMERICAL SIMULATION OF FLUE-GAS DESULFURIZATION ABSORPTION TOWER CIRCULATING PUMP
    Liu Jianrui
    He Xiaoke
    Guo Chenxu
    Wen Haigang
    Gao Zhenjun
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2012, VOL 1, PTS A AND B, SYMPOSIA, 2012, : 419 - 425
  • [36] Eulerian-Eulerian numerical simulation for a flue gas desulfurization tower with perforated sieve trays
    Tseng, Chien-Chou
    Li, Cheng-Jui
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 116 : 329 - 345
  • [37] Thermodynamic Analysis of Pyrolusite for Dry Flue Gas Desulfurization
    Wang, Wenhao
    Wu, Fuzhong
    Wang, Keke
    Jin, Huixin
    ENVIRONMENTS, 2016, 3 (01): : 1 - 9
  • [38] DRY FLUE-GAS DESULFURIZATION BY THE LIFAC PROCESS
    KENAKKALA, T
    LAINE, J
    NON-WASTE TECHNOLOGY, VOL II, 1989, 103 : 285 - 293
  • [39] MODELING OF DRY INJECTION FLUE-GAS DESULFURIZATION
    GARDING, M
    SVEDBERG, G
    JAPCA-THE INTERNATIONAL JOURNAL OF AIR POLLUTION CONTROL AND HAZARDOUS WASTE MANAGEMENT, 1988, 38 (10): : 1275 - 1280
  • [40] Numerical simulation of semi-dry flue gas desulfurization retrofit and operation tests
    Jicha, M. (jicha@fme.vutbr.cz), 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (31):