Wearable biosensors for human fatigue diagnosis: A review

被引:19
作者
Zhang, Jingyang [1 ]
Chen, Mengmeng [1 ]
Peng, Yuan [1 ]
Li, Shuang [1 ]
Han, Dianpeng [1 ]
Ren, Shuyue [1 ]
Qin, Kang [1 ]
Li, Sen [1 ]
Han, Tie [1 ]
Wang, Yu [1 ]
Gao, Zhixian [1 ]
机构
[1] Inst Environm & Operat Med, Tianjin Key Lab Risk Assessment & Control Technol, Tianjin 300050, Peoples R China
关键词
fatigue diagnosis; real-time monitoring; sensing modules; wearable biosensors; URIC-ACID; SWEAT PH; BLOOD; GLUCOSE; SALIVA; SENSOR; TEAR; SOFT; TECHNOLOGY; ALCOHOL;
D O I
10.1002/btm2.10318
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Fatigue causes deleterious effects to physical and mental health of human being and may cause loss of lives. Therefore, the adverse effects of fatigue on individuals and the society are massive. With the ever-increasing frequency of overtraining among modern military and sports personnel, timely, portable and accurate fatigue diagnosis is essential to avoid fatigue-induced accidents. However, traditional detection methods require complex sample preparation and blood sampling processes, which cannot meet the timeliness and portability of fatigue diagnosis. With the development of flexible materials and biosensing technology, wearable biosensors have attracted increased attention to the researchers. Wearable biosensors collect biomarkers from noninvasive biofluids, such as sweat, saliva, and tears, followed by biosensing with the help of biosensing modules continuously and quantitatively. The detection signal can then be transmitted through wireless communication modules that constitute a method for real-time understanding of abnormality. Recent developments of wearable biosensors are focused on miniaturized wearable electrochemistry and optical biosensors for metabolites detection, of which, few have exhibited satisfactory results in medical diagnosis. However, detection performance limits the wide-range applicability of wearable fatigue diagnosis. In this article, the application of wearable biosensors in fatigue diagnosis has been discussed. In fact, exploration of the composition of different biofluids and their potential toward fatigue diagnosis have been discussed here for the very first time. Moreover, discussions regarding the current bottlenecks in wearable fatigue biosensors and the latest advancements in biochemical reaction and data communication modules have been incorporated herein. Finally, the main challenges and opportunities were discussed for wearable fatigue diagnosis in the future.
引用
收藏
页数:18
相关论文
共 145 条
[1]   WiFi-Based Driver's Activity Monitoring with Efficient Computation of Radio-Image Features [J].
Akhtar, Zain Ul Abiden ;
Wang, Hongyu .
SENSORS, 2020, 20 (05)
[2]   Enzyme inhibition-based biosensors for food safety and environmental monitoring [J].
Amine, A ;
Mohammadi, H ;
Bourais, I ;
Palleschi, G .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1405-1423
[3]   Measurement of hexanal production by myoglobin-induced lipid peroxidation using a miniature incubator and cryofocusing inlet system with gas chromatography and time-of-flight mass spectrometry [J].
Amunugama, M ;
Clifford, CD ;
Gutman, PM ;
Soltani, M ;
Karunaratne, S ;
Venkatachalam, K ;
Pernecky, SJ ;
Holmes, HLS .
CHROMATOGRAPHIA, 2004, 60 (7-8) :441-447
[4]   Proteomic and histopathological characterisation of sicca subjects and primary Sjogren's syndrome patients reveals promising tear, saliva and extracellular vesicle disease biomarkers [J].
Aqrawi, Lara A. ;
Galtung, Hilde Kanli ;
Guerreiro, Eduarda M. ;
Ovstebo, Reidun ;
Thiede, Bernd ;
Utheim, Tor Paaske ;
Chen, Xiangjun ;
Utheim, Oygunn Aass ;
Palm, Oyvind ;
Skarstein, Kathrine ;
Jensen, Janicke Liaaen .
ARTHRITIS RESEARCH & THERAPY, 2019, 21 (1)
[5]   Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor [J].
Arakawa, Takahiro ;
Kuroki, Yusuke ;
Nitta, Hiroki ;
Chouhan, Prem ;
Toma, Koji ;
Sawada, Shin-ichi ;
Takeuchi, Shuhei ;
Sekita, Toshiaki ;
Akiyoshi, Kazunari ;
Minakuchi, Shunsuke ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2016, 84 :106-111
[6]   Slight power output manipulations around the maximal lactate steady state have a similar impact on fatigue in females and males [J].
Azevedo, Rafael de Almeida ;
Forot, Jonas ;
Iannetta, Danilo ;
MacInnis, Martin J. ;
Millet, Guillaume Y. ;
Murias, Juan M. .
JOURNAL OF APPLIED PHYSIOLOGY, 2021, 130 (06) :1879-1892
[7]   Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability [J].
Baker, Lindsay B. .
SPORTS MEDICINE, 2017, 47 :S111-S128
[8]   Electrochemical sensors and biosensors based on redox polymer/carbon nanotube modified electrodes: A review [J].
Barsan, Madalina M. ;
Ghica, M. Emilia ;
Brett, Christopher M. A. .
ANALYTICA CHIMICA ACTA, 2015, 881 :1-23
[9]   A Review of the Construction of Nano-Hybrids for Electrochemical Biosensing of Glucose [J].
Batool, Razia ;
Rhouati, Amina ;
Nawaz, Mian Hasnain ;
Hayat, Akhtar ;
Marty, Jean Louis .
BIOSENSORS-BASEL, 2019, 9 (01)
[10]   Simultaneous lancet-free monitoring of alcohol and glucose from low-volumes of perspired human sweat [J].
Bhide, Ashlesha ;
Muthukumar, Sriram ;
Saini, Amreek ;
Prasad, Shalini .
SCIENTIFIC REPORTS, 2018, 8