Bio-conjugated nanoarchitectonics with dual-labeled nanoparticles for a colorimetric and fluorescent dual-mode serological lateral flow immunoassay sensor in detection of SARS-CoV-2 in clinical samples

被引:11
|
作者
Kim, Sang Ki [1 ]
Lee, Jong Uk [2 ]
Jeon, Myeong Jin [1 ]
Kim, Soo-Kyung [3 ]
Hwang, Sang-Hyun [4 ]
Hong, Min Eui [5 ]
Sim, Sang Jun [1 ]
机构
[1] Korea Univ, Dept Chem & Biol Engn, 145 Anam ro, Seoul 02841, South Korea
[2] Sunchon Natl Univ, Dept Chem Engn, 225 Jungang ro, Sunchon 57922, Jeollanam Do, South Korea
[3] Ewha Womans Univ, Mokdong Hosp, Dept Lab Med, Seoul 07985, South Korea
[4] Univ Ulsan, Asan Med Ctr, Dept Lab Med, Coll Med, Seoul 05505, South Korea
[5] Kyung Nam Pharm Co Ltd, Business Dev, 702 Eonju ro, Seoul 06061, South Korea
基金
新加坡国家研究基金会;
关键词
Antibody detection - Bio-conjugated - Clinical samples - Detection methods - Diagnostic procedure - Dual modes - Infectious disease - Lateral flow immunoassay - Metal enhanced fluorescence - Site application;
D O I
10.1039/d3ra04373h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Serological detection of antibodies for diagnosing infectious diseases has advantages in facile diagnostic procedures, thereby contributing to controlling the spread of the pathogen, such as in the recent SARS-CoV-2 pandemic. Lateral flow immunoassay (LFIA) is a representative serological antibody detection method suitable for on-site applications but suffers from low clinical accuracy. To achieve a simple and rapid serological screening as well as the sensitive quantification of antibodies against SARS-CoV-2, a colorimetric and fluorescent dual-mode serological LFIA sensor incorporating metal-enhanced fluorescence (MEF) was developed. For the strong fluorescence signal amplification, fluorophore Cy3 was immobilized onto gold nanoparticles (AuNPs) with size-controllable spacer polyethyleneglycol (PEG) to maintain an optimal distance to induce MEF. The sensor detects the target IgG with a concentration as low as 1 ng mL-1 within 8 minutes. The employment of the MEF into the dual-mode serological LFIA sensor shows a 1000-fold sensitivity improvement compared with that of colorimetric LFIAs. The proposed serological LFIA sensor was tested with 73 clinical samples, showing sensitivity, specificity, and accuracy of 95%, 100%, and 97%, respectively. In conclusion, the dual-mode serological LFIA has great potential for application in diagnosis and an epidemiological survey of vaccine efficacy and immunity status of individuals. A colorimetric-fluorescent dual-mode lateral flow immunoassay sensor incorporating metal-enhanced fluorescence (MEF) for the rapid and sensitive serological detection of SARS-CoV-2 IgG was developed.
引用
收藏
页码:27225 / 27232
页数:8
相关论文
共 26 条
  • [21] Gold-silver alloy hollow nanoshells-based lateral flow immunoassay for colorimetric, photothermal, and SERS tri-mode detection of SARS-CoV-2 neutralizing antibody
    Zhao, Tianyu
    Liang, Penghui
    Ren, Jiaqi
    Zhu, Jinyue
    Yang, Xianning
    Bian, Hongyu
    Li, Jingwen
    Cui, Xiaofeng
    Fu, Chunhui
    Xing, Jinyan
    Wen, Congying
    Zeng, Jingbin
    ANALYTICA CHIMICA ACTA, 2023, 1255
  • [22] Gold nanoparticle conjugate-based lateral flow immunoassay (LFIA) for rapid detection of RBD antigen of SARS-CoV-2 in clinical samples using a smartphone-based application
    Prakashan, Drishya
    Shrikrishna, Narlawar S.
    Byakodi, Manisha
    Nagamani, K.
    Gandhi, Sonu
    JOURNAL OF MEDICAL VIROLOGY, 2023, 95 (01)
  • [23] High-density Au nanoshells assembled onto Fe3O4 nanoclusters for integrated enrichment and photothermal/colorimetric dual-mode detection of SARS-CoV-2 nucleocapsid protein
    Li, Xiang
    Yu, Dong
    Li, Huiwen
    Sun, Ruichang
    Zhang, Zhuoran
    Zhao, Tianyu
    Guo, Gengchen
    Zeng, Jingbin
    Wen, Cong-Ying
    BIOSENSORS & BIOELECTRONICS, 2023, 241
  • [24] Development of receptor binding domain-based double-antigen sandwich lateral flow immunoassay for the detection and evaluation of SARS-CoV-2 neutralizing antibody in clinical sera samples compared with the conventional virus neutralization test
    Zhang, Ying
    Chen, Yixiao
    He, Yong
    Li, Yizhe
    Zhang, Xiaoli
    Liang, Jiajie
    He, Jinyong
    Lu, Shaofang
    Gao, Zhixing
    Xu, Jianhua
    Tang, Yong
    TALANTA, 2023, 255
  • [25] RETRACTED: Differential detection of SARS-CoV-2 variants and influenza A viruses utilizing a dual lateral flow strip based on colloidal gold-labeled monoclonal antibodies (Retracted article. See vol. 305, 2025)
    Li, Ge
    Wang, Xun
    Guo, Junqing
    Wang, Yao
    Liu, Xiao
    Wei, Qiang
    Zhang, Yuhang
    Sun, Yaning
    Fan, Lu
    Xing, Yunrui
    Li, Qingmei
    Zhang, Gaiping
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2024, 280
  • [26] RETRACTION: Retraction notice to "Differential detection of SARS-CoV-2 variants and influenza A viruses utilizing a dual lateral flow strip based on colloidal gold-labeled monoclonal antibodies" [Int. J. Biol. Macromol. 280P4 (2024) 136067]
    Li, Ge
    Wang, Xun
    Guo, Junqing
    Wang, Yao
    Liu, Xiao
    Wei, Qiang
    Zhang, Yuhang
    Sun, Yaning
    Fan, Lu
    Xing, Yunrui
    Li, Qingmei
    Zhang, Gaiping
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2025, 305