Repeatability of Open-MOLLI: An open-source inversion recovery myocardial T1 mapping sequence for fast prototyping

被引:2
作者
Gaspar, Andreia S. [1 ,2 ,6 ,7 ]
Silva, Nuno A. [3 ]
Ferreira, Antonio M. [4 ,5 ]
Nunes, Rita G. [1 ,2 ]
机构
[1] Univ Lisbon, Inst Sistemas & Robot Lisboa, Lisbon, Portugal
[2] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[3] Luz Saude, Hosp Luz Learning Hlth, Lisbon, Portugal
[4] Ctr Hosp Lisboa Ocidental, Hosp Santa Cruz, Serv Cardiol, Lisbon, Portugal
[5] Hosp Luz, Unidade Imagiol Cardiaca Avancada, Lisbon, Portugal
[6] Univ Lisbon, Inst Sistemas & Robot Lisboa, P-1049001 Lisbon, Portugal
[7] Univ Lisbon, Dept Bioengn, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
cardiac MRI; open-source; Pulseq; repeatability; T1; mapping; PULSE SEQUENCE; REPRODUCIBILITY; ACCURACY; VALUES;
D O I
10.1002/mrm.30080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. Methods: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). Results: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1(vial3) = 1027 ms): T1(MOLLI) = 1011 +/- 24 ms versus T1(Open-MOLLI) = 1009 +/- 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1(MOLLI) = 1004 +/- 33 ms vs. T1(Open-MOLLI) = 998 +/- 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). Conclusion: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 29 条
[21]  
Ravi K., 2019, Joss, V4, P1725, DOI DOI 10.21105/JOSS.01725
[22]   Accuracy, Precision, and Reproducibility of Four T1 Mapping Sequences: A Head-to-Head Comparison of MOLLI, ShMOLLI, SASHA, and SAPPHIRE [J].
Roujol, Sebastien ;
Weingaertner, Sebastian ;
Foppa, Murilo ;
Chow, Kelvin ;
Kawaji, Keigo ;
Ngo, Long H. ;
Kellman, Peter ;
Manning, Warren J. ;
Thompson, Richard B. ;
Nezafat, Reza .
RADIOLOGY, 2014, 272 (03) :683-689
[23]   A standard system phantom for magnetic resonance imaging [J].
Stupic, Karl F. ;
Ainslie, Maureen ;
Boss, Michael A. ;
Charles, Cecil ;
Dienstfrey, Andrew M. ;
Evelhoch, Jeffrey L. ;
Finn, Paul ;
Gimbutas, Zydrunas ;
Gunter, Jeffrey L. ;
Hill, Derek L. G. ;
Jack, Clifford R. ;
Jackson, Edward F. ;
Karaulanov, Todor ;
Keenan, Kathryn E. ;
Liu, Guoying ;
Martin, Michele N. ;
Prasad, Pottumarthi, V ;
Rentz, Nikki S. ;
Yuan, Chun ;
Russek, Stephen E. .
MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (03) :1194-1211
[24]   Controlled saturation magnetization transfer for reproducible multivendor variable flip angle T1 and T2 mapping [J].
Teixeira, Rui Pedro A. G. ;
Neji, Radhouene ;
Wood, Tobias C. ;
Baburamani, Ana A. ;
Malik, Shaihan J. ;
Hajnal, Joseph V. .
MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) :221-236
[25]   A framework for validating open-source pulse sequences [J].
Tong, Gehua ;
Gaspar, Andreia S. ;
Qian, Enlin ;
Ravi, Keerthi Sravan ;
Vaughan, John Thomas, Jr. ;
Nunes, Rita G. ;
Geethanath, Sairam .
MAGNETIC RESONANCE IMAGING, 2022, 87 :7-18
[26]   Open-Source MR Imaging and Reconstruction Workflow [J].
Veldmann, Marten ;
Ehses, Philipp ;
Chow, Kelvin ;
Nielsen, Jon-Fredrik ;
Zaitsev, Maxim ;
Stoecker, Tony .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) :2395-2407
[27]   Development, validation, qualification, and dissemination of quantitative MR methods: Overview and recommendations by the ISMRM quantitative MR study group [J].
Weingartner, Sebastian ;
Desmond, Kimberly L. ;
Obuchowski, Nancy A. ;
Baessler, Bettina ;
Zhang, Yuxin ;
Biondetti, Emma ;
Ma, Dan ;
Golay, Xavier ;
Boss, Michael A. ;
Gunter, Jeffrey L. ;
Keenan, Kathryn E. ;
Hernando, Diego .
MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (03) :1184-1206
[28]   Phase-Sensitive Inversion Recovery for Myocardial T1 Mapping with Motion Correction and Parametric Fitting [J].
Xue, Hui ;
Greiser, Andreas ;
Zuehlsdorff, Sven ;
Jolly, Marie-Pierre ;
Guehring, Jens ;
Arai, Andrew E. ;
Kellman, Peter .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1408-1420
[29]  
Ye S., 2022, BJR OPEN, V4