Repeatability of Open-MOLLI: An open-source inversion recovery myocardial T1 mapping sequence for fast prototyping

被引:2
作者
Gaspar, Andreia S. [1 ,2 ,6 ,7 ]
Silva, Nuno A. [3 ]
Ferreira, Antonio M. [4 ,5 ]
Nunes, Rita G. [1 ,2 ]
机构
[1] Univ Lisbon, Inst Sistemas & Robot Lisboa, Lisbon, Portugal
[2] Univ Lisbon, Dept Bioengn, Inst Super Tecn, Lisbon, Portugal
[3] Luz Saude, Hosp Luz Learning Hlth, Lisbon, Portugal
[4] Ctr Hosp Lisboa Ocidental, Hosp Santa Cruz, Serv Cardiol, Lisbon, Portugal
[5] Hosp Luz, Unidade Imagiol Cardiaca Avancada, Lisbon, Portugal
[6] Univ Lisbon, Inst Sistemas & Robot Lisboa, P-1049001 Lisbon, Portugal
[7] Univ Lisbon, Dept Bioengn, Inst Super Tecn, P-1049001 Lisbon, Portugal
关键词
cardiac MRI; open-source; Pulseq; repeatability; T1; mapping; PULSE SEQUENCE; REPRODUCIBILITY; ACCURACY; VALUES;
D O I
10.1002/mrm.30080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop an open-source prototype of myocardial T1 mapping (Open-MOLLI) to improve accessibility to cardiac T1 mapping and evaluate its repeatability. With Open-MOLLI, we aim to enable faster implementation and testing of sequence modifications and to facilitate inter-scanner and cross-vendor reproducibility studies. Methods: Open-MOLLI is an inversion-recovery sequence using a balanced SSFP (bSSFP) readout, with inversion and triggering schemes based on the 5(3)3 MOLLI sequence, developed in Pulseq. Open-MOLLI and MOLLI sequences were acquired in the ISMRM/NIST phantom and 21 healthy volunteers. In 18 of those subjects, Open-MOLLI and MOLLI were repeated in the same session (test-retest). Results: Phantom T1 values were comparable between methods, specifically for the vial with reference T1 value most similar to healthy myocardium T1 (T1(vial3) = 1027 ms): T1(MOLLI) = 1011 +/- 24 ms versus T1(Open-MOLLI) = 1009 +/- 20 ms. In vivo T1 estimates were similar between Open-MOLLI and MOLLI (T1(MOLLI) = 1004 +/- 33 ms vs. T1(Open-MOLLI) = 998 +/- 52 ms), with a mean difference of -17 ms (p = 0.20), despite noisier Open-MOLLI weighted images and maps. Repeatability measures were slightly higher for Open-MOLLI (RCMOLLI = 3.0% vs. RCOpen-MOLLI = 4.4%). Conclusion: The open-source sequence Open-MOLLI can be used for T1 mapping in vivo with similar mean T1 values to the MOLLI method. Open-MOLLI increases the accessibility to cardiac T1 mapping, providing also a base sequence to which further improvements can easily be added and tested.
引用
收藏
页码:741 / 750
页数:10
相关论文
共 29 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   T1 mapping performance and measurement repeatability: results from the multi-national T1 mapping standardization phantom program (T1MES) [J].
Captur, Gabriella ;
Bhandari, Abhiyan ;
Bruehl, Ruediger ;
Ittermann, Bernd ;
Keenan, Kathryn E. ;
Yang, Ye ;
Eames, Richard J. ;
Benedetti, Giulia ;
Torlasco, Camilla ;
Ricketts, Lewis ;
Boubertakh, Redha ;
Fatih, Nasri ;
Greenwood, John P. ;
Paulis, Leonie E. M. ;
Lawton, Chris B. ;
Bucciarelli-Ducci, Chiara ;
Lamb, Hildo J. ;
Steeds, Richard ;
Leung, Steve W. ;
Berry, Colin ;
Valentin, Sinitsyn ;
Flett, Andrew ;
de Lange, Charlotte ;
DeCobelli, Francesco ;
Viallon, Magalie ;
Croisille, Pierre ;
Higgins, David M. ;
Greiser, Andreas ;
Pang, Wenjie ;
Hamilton-Craig, Christian ;
Strugnell, Wendy E. ;
Dresselaers, Tom ;
Barison, Andrea ;
Dawson, Dana ;
Taylor, Andrew J. ;
Mongeon, Francois-Pierre ;
Plein, Sven ;
Messroghli, Daniel ;
Al-Mallah, Mouaz ;
Grieve, Stuart M. ;
Lombardi, Massimo ;
Jang, Jihye ;
Salerno, Michael ;
Chaturvedi, Nish ;
Kellman, Peter ;
Bluemke, David A. ;
Nezafat, Reza ;
Gatehouse, Peter ;
Moon, James C. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
[3]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) :240-245
[4]   QUANTIFICATION OF T1 VALUES BY SNAPSHOT-FLASH NMR IMAGING [J].
DEICHMANN, R ;
HAASE, A .
JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (03) :608-612
[5]  
Freitas AC., 2022, P 2022 ISMRM SMRT AN, P1263
[6]   Open-source myocardial T1 mapping with simultaneous multi-slice acceleration: Combining an auto-calibrated blipped-bSSFP readout with VERSE-MB pulses [J].
Gaspar, Andreia S. ;
Silva, Nuno A. ;
Price, Anthony N. ;
Ferreira, Antonio M. ;
Nunes, Rita G. .
MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) :539-551
[7]  
Gaspar AS., 2021, P 2021 ISMRM SMRT AN, P3599
[8]  
Gaspar AS., 2023, P 2023 ISMRM SMRT AN, P5085
[9]   Comparison of native myocardial T1 and T2 mapping at 1.5T and 3T in healthy volunteers Reference values and clinical implications [J].
Granitz, Marcel ;
Motloch, Lukas J. ;
Granitz, Christina ;
Meissnitzer, Matthias ;
Hitzl, Wolfgang ;
Hergan, Klaus ;
Schlattau, Alexander .
WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 (7-8) :143-155
[10]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210