摘要
Raman spectroscopy is considered a Process Analytical Technology (PAT) tool in biopharmaceutical downstream processes. In the past decade, researchers have shown Raman spectroscopy's feasibility in determining Critical Quality Attributes (CQAs) in bioprocessing. This study verifies the feasibility of implementing a Raman-based PAT tool in Protein A chromatography as a CQA monitoring technique, for the purpose of accelerating process development and achieving real-time release in manufacturing. A system connecting Raman to a Tecan liquid handling station enables high-throughput model calibration. One calibration experiment collects Raman spectra of 183 samples with 8 CQAs within 25 h. After applying Butterworth high-pass filters and k-nearest neighbor (KNN) regression for model training, the model showed high predictive accuracy for fragments (Q2 = 0.965) and strong predictability for target protein concentration, aggregates, as well as charge variants (Q2 >= 0.922). The model's robustness was confirmed by varying the elution pH, load density, and residence time using 19 external validation preparative Protein A chromatography runs. The model can deliver elution profiles of multiple CQAs within a set point +/- 0.3 pH range. The CQA readouts were presented as continuous chromatograms with a resolution of every 28 s for enhanced process understanding. In external validation datasets, the model maintained strong predictability especially for target protein concentration (Q2 = 0.956) and basic charge variants (Q2 = 0.943), except for overpredicted HCP (Q2 = 0.539). This study demonstrates a rapid, effective method for implementing Raman spectroscopy for in-line CQA monitoring in process development and biomanufacturing, eliminating the need for labor-intensive sample pooling and handling.
引用
收藏
页数:9
相关论文
共 8 条
  • [1] Simultaneous prediction of 16 quality attributes during protein A chromatography using machine learning based Raman spectroscopy models
    Wang, Jiarui
    Chen, Jingyi
    Studts, Joey
    Wang, Gang
    BIOTECHNOLOGY AND BIOENGINEERING, 2024, 121 (05) : 1729 - 1738
  • [2] Real-time determination of critical quality attributes using near-infrared spectroscopy: A contribution for Process Analytical Technology (PAT)
    Rosas, Juan G.
    Blanco, Marcel
    Gonzalez, Josep M.
    Alcala, Mane
    TALANTA, 2012, 97 : 163 - 170
  • [3] Online/at-line measurement, analysis and control of product titer and critical product quality attributes (CQAs) during process development
    Chemmalil, Letha
    Prabhakar, Tanushree
    Kuang, June
    West, Jay
    Tan, Zhijun
    Ehamparanathan, Vivekh
    Song, Yuanli
    Xu, Jianlin
    Ding, Julia
    Li, Zhengjian
    BIOTECHNOLOGY AND BIOENGINEERING, 2020, 117 (12) : 3757 - 3765
  • [4] Application of Mid-Infrared Spectroscopy to the Development and Transfer of a Manufacturing Process for an Active Pharmaceutical Ingredient
    Clegg, Ian M.
    Daly, Adrian M.
    Donnelly, Craig
    Hardy, Ruth
    Harris, Denise
    Jackman, Hayley
    Jones, Ricky
    Luan, Amy
    McAndrew, Douglas
    McGauley, Pat
    Pearce, John
    Scotney, Gemma
    Yeow, May-Ling
    APPLIED SPECTROSCOPY, 2012, 66 (05) : 574 - 579
  • [5] Quick generation of Raman spectroscopy based in-process glucose control to influence biopharmaceutical protein product quality during mammalian cell culture
    Berry, Brandon N.
    Dobrowsky, Terrence M.
    Timson, Rebecca C.
    Kshirsagar, Rashmi
    Ryll, Thomas
    Wiltberger, Kelly
    BIOTECHNOLOGY PROGRESS, 2016, 32 (01) : 224 - 234
  • [6] Raman spectroscopy for the determination of coating uniformity of tablets: Assessment of product quality and coating pan mixing efficiency during scale-up
    El Hagrasy A.S.
    Chang S.-Y.
    Desal D.
    Kiang S.
    Journal of Pharmaceutical Innovation, 2006, 1 (1) : 37 - 42
  • [7] Development of a Calibration Model for Real-Time Solute Concentration Monitoring during Crystallization of Ceritinib Using Raman Spectroscopy and In-Line Process Microscopy
    Gavran, Matea
    Andrijic, Zeljka Ujevic
    Bolf, Nenad
    Rimac, Nikola
    Sacher, Josip
    Sahnic, Damir
    PROCESSES, 2023, 11 (12)
  • [8] The application of dual-electrode through vial impedance spectroscopy for the determination of ice interface temperatures, primary drying rate and vial heat transfer coefficient in lyophilization process development
    Smith, Geoff
    Jeeraruangrattana, Yowwares
    Ermolina, Irina
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2018, 130 : 224 - 235