Performance investigation and numerical evaluation of a single-effect double-lift absorption chiller

被引:11
作者
Saoud, Abdelmajid [1 ]
Bruno, Joan Carles [2 ]
Boukhchanaa, Yasmina [1 ]
Fellah, Ali [3 ]
机构
[1] Univ Gabes, Natl Sch Engineers Gabes, Lab Appl Thermodynam, LR18ES33, Gabes 6029, Tunisia
[2] Univ Rovira I Virgili, Mech Engn Dept, CREVER Res Grp Appl Thermal Engn, Ave Paisos Catalans 26, Tarragona 43007, Spain
[3] Univ Gabes, Higher Inst Appl Sci & Technol Gabes, Lab Appl Thermodynam LR18ES33, Gabes 6029, Tunisia
关键词
Single-effect double-lift absorption chiller (SE-DL AC); Refrigeration; Coefficient of Performance (COP); Thermodynamic analysis; Glide temperature(?T); Energy efficiency; REFRIGERATION SYSTEM; COOLING SYSTEMS; EXERGY ANALYSIS; SOLAR-ENERGY; LICL-H2O; INVERSE; DRIVEN;
D O I
10.1016/j.applthermaleng.2023.120369
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study deals with innovative integrated absorption refrigeration systems. This cycle could be useful for converting low-temperature energy sources into useful outputs like cooling. The Single Effect Double Lift Ab-sorption Chiller (SE-DL AC) was introduced and energetically evaluated. A detailed modeling based on the first law of thermodynamics is built to investigate the performance of this novel system. This model was initially validated considering a reference SE-DL AC from the Hitachi company with a nominal cooling capacity of 106.1 kW. This system is compared to a conventional single-effect absorption chiller while maintaining the same operating parameters and boundary conditions in both configurations to ensure a fair comparison in terms of the internal and external baseline operating conditions. A parametric study of the driving hot water inlet temper-ature, the solution mass flow rate, the effectiveness of the solution heat exchanger, and internal and external temperatures on the Coefficient of Performance (COP), Cooling capacity (CC), and Glide Temperature (Delta T) are conducted. The final results demonstrate that the cooling production capability of the SE-DL is increased by an average of about tenfold when compared to the conventional SE AC at a thermal source temperature of 88.7 degrees C and an inlet hot water mass flow rate of 1 kg/s. The COP results produced under the same operating conditions are quite similar. The cooling generation capability of the SEDL is, on average, 10 times greater than that of the traditional SE AC. This explains that the SEDL-AC is well suited for a wide range of low-temperature heat sources (e.g., solar energy). Furthermore, the SE-DL AC enables efficient use of low-grade heat with a high glide tem-perature in the driving heat stream of about 10 times (36 degrees C instead of 3.5 degrees C). This large temperature difference exemplifies that the SE-DL AC absorption chiller is an alternative for extracting as much heat as possible, thereby improving cold production.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Design and 3E analysis of a hybrid power plant integrated with a single-effect absorption chiller driven by a heliostat field: A case study for Doha, Qatar
    Nedaei, Navid
    Hamrang, Farzad
    Farshi, L. Garousi
    ENERGY, 2022, 239
  • [22] Experimental studies of a single-effect absorption refrigerator using aqueous lithium-bromide: Effect of operating condition to system performance
    Aphornratana, Satha
    Sriveerakul, Thanarath
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (02) : 658 - 669
  • [23] Operation strategy of a solar-gas fired single/double effect absorption chiller for space cooling in Indonesia
    Alhamid, M., I
    Coronas, Alberto
    Lubis, Arnas
    Ayou, Dereje S.
    Nasruddin
    Saito, Kiyoshi
    Yabase, Hajime
    APPLIED THERMAL ENGINEERING, 2020, 178
  • [24] Downsizing strategy for an air-cooled indirect-fired single-effect ammonia-water absorption chiller in part-load operation in hot climates
    Palacios-Lorenzo, Maria Esther
    Marcos, Jose Daniel
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 53
  • [25] Comparison of the performance of single-effect, half-effect, double-effect in series and inverse and triple-effect absorption cooling systems operating with the NH3-LiNO3 mixture
    Dominguez-Inzunza, L. A.
    Hernandez-Magallanes, J. A.
    Sandoval-Reyes, M.
    Rivera, W.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 612 - 620
  • [26] Research on Energy-Saving Control Strategies for Single-Effect Absorption Refrigeration Systems
    Liu, Zhenchang
    Wu, Aiguo
    Wen, Haitang
    ENERGIES, 2024, 17 (18)
  • [27] Thermodynamic analysis of a solar-biomass cogeneration power and cooling by employing an ejector and single-effect absorption refrigeration system
    Parvez, Mohd
    Khan, Osama
    Lal, Shiv
    Ahmad, Mumtaz
    BIOMASS & BIOENERGY, 2024, 184
  • [28] Charging and discharging characteristics of absorption energy storage integrated with a solar driven double-effect absorption chiller for air conditioning applications
    Ibrahim, Nasiru I.
    Al-Sulaiman, Fahad A.
    Saat, Aminuddin
    Rehman, Shafiqur
    Ani, Farid Nasir
    JOURNAL OF ENERGY STORAGE, 2020, 29
  • [29] Performance Evaluation And Sensitivity Analysis Of A Low-capacity Single-effect LiBr-H2O Absorption Cooling System Using Energy And Exergy Modeling
    Hasan, Syed Maaz
    Ul Haq, Muhammad Saad
    Badar, Abdul Waheed
    Qureshi, M. Zahid Iqbal
    Ali, Majid
    Siddiqi, M. Salman
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2025, 28 (09): : 1705 - 1715
  • [30] Heat current method-based modeling and optimization of the single effect lithium bromide absorption chiller
    Zhao, Tian
    Chen, Xi
    Chen, Qun
    APPLIED THERMAL ENGINEERING, 2020, 175