Energy management of hybrid PV/diesel/battery systems: A modified flow direction algorithm for optimal sizing design - A case study in Luxor, Egypt

被引:11
|
作者
Elfatah, Atef A. [1 ]
Hashim, Fatma A. [2 ,3 ]
Mostafa, Reham R. [4 ,5 ]
Abd El-Sattar, Hoda [6 ]
Kamel, Salah [1 ]
机构
[1] Aswan Univ, Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
[2] Helwan Univ, Fac Engn, Helwan, Egypt
[3] Middle East Univ, MEU Res Unit, Amman 11831, Jordan
[4] Univ Sharjah, Res Inst Sci & Engn RISE, Sharjah 27272, U Arab Emirates
[5] Mansoura Univ, Fac Comp & Informat Sci, Informat Syst Dept, Mansoura 35516, Egypt
[6] Luxor Higher Inst Engn & Technol, Elect Engn Dept, Luxor 85834, Egypt
关键词
Optimal sizing components; Solar PV; Diesel generators (DG); Battery bank; Hybrid microgrids components; Optimization techniques; MICROGRID SYSTEM; COST-ANALYSIS; WIND; OPTIMIZATION; HYDROGEN; LOAD;
D O I
10.1016/j.renene.2023.119333
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hybrid systems have emerged as a reliable solution to meet the increasing demand loads in various fields and address the electricity shortage in remote areas. Consequently, research efforts have been directed towards determining the optimal sizing of hybrid system components to cater to different areas' demand loads. Effective energy management of hybrid micro-grid components is essential to ensure the delivery of high-quality and cost-effective power supply globally. Various optimization techniques have been employed to achieve this objective and determine optimal solutions. This paper proposes an improved version of the Flow Direction Algorithm (FDA), named mFDA, to determine the optimal sizing of a standalone system comprising solar panels, a diesel generator (DG), and a battery bank to meet the demand load in Luxor, Egypt. The primary objective of this research is to reduce the cost of energy (COE) of the system, the net present cost (NPC) of the proposed hybrid power system, the probability of a power supply loss (LPSP), and the size of a microgrid's components. The proposed methodology aims to provide an effective solution to optimize the hybrid system's performance and energy management, which can be applied in other regions as well. To achieve economic energy with high quality and effective sizing with the lowest annual cost in the shortest amount of time, Results from the proposed mFDA are evaluated with those from the original (FDA), Grey Wolf Optimizer (GWO), Gorilla Troops Optimizer (GTO), a new Optimization technique based on COOT Bird Natural Life Model (COOT), and Smell Agent Optimization (SAO) algorithm. The MATLAB program's simulation results indicate that the proposed modified mFDA algorithm performs better than other algorithms when it comes to designing hybrid microgrid component sizing. After 44 iterations, the mFDA approach demonstrates stable convergence characteristics and achieves a minimum Cost of Energy (COE) of approximately 0.2658555/kWh, a Low Probability of Sustainable Power (LPSP) of 0.06555, and a Net Present Cost (NPC) of 7,767,179. The original FDA method closely follows, attaining a COE of about 0.2658555/kWh, LPSP of 0.06555, and NPC of 7,767,179.
引用
收藏
页数:19
相关论文
共 46 条
  • [41] Optimal Design of Standalone Hybrid Renewable Energy Systems with Biochar Production in Remote Rural Areas: A Case Study
    Li, Lanyu
    You, Siming
    Wang, Xiaonan
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 688 - 693
  • [42] Optimal configuration of a stand-alone PV/diesel/battery hybrid energy system based on modified PSO for a translational sprinkler irrigation machine applied in remote and water-scarce areas
    Liu, Kenan
    Cai, Yaohui
    Sun, Wei
    Feng, Quan
    Wang, Guanping
    Yang, Wanxia
    ENERGY, 2025, 320
  • [43] A fuzzy decision-making model for optimal design of solar, wind, diesel-based RO desalination integrating flow-battery and pumped-hydro storage: Case study in Baltim, Egypt
    Kotb, Kotb M.
    Elkadeem, M. R.
    Khalil, Ahmed
    Imam, Sherif M.
    Hamada, Mohamed A.
    Sharshir, Swellam W.
    Dan, Andras
    ENERGY CONVERSION AND MANAGEMENT, 2021, 235
  • [44] Optimization and enviro-economic assessment of hybrid sustainable energy systems: The case study of a photovoltaic/biogas/diesel/battery system in Xuzhou, China
    Li, Chong
    Zhang, Lin
    Qiu, Fei
    Fu, Rui
    ENERGY STRATEGY REVIEWS, 2022, 41
  • [45] Optimal design and sensitivity analysis of distributed biomass-based hybrid renewable energy systems for rural electrification: Case study of different photovoltaic/wind/battery-integrated options in Babadam, northern Cameroon
    Yimen, Nasser
    Monkam, Louis
    Tcheukam-Toko, Denis
    Musa, Bashir
    Abang, Roger
    Fombe, Lawrence Fon
    Abbasoglu, Serkan
    Dagbasi, Mustafa
    IET RENEWABLE POWER GENERATION, 2022, 16 (14) : 2939 - 2956
  • [46] A flexible metamodel architecture for optimal design of Hybrid Renewable Energy Systems (HRES) - Case study of a stand-alone HRES for a factory in tropical island
    Roth, Anastasia
    Boix, Marianne
    Gerbaud, Vincent
    Montastruc, Ludovic
    Etur, Philippe
    JOURNAL OF CLEANER PRODUCTION, 2019, 223 : 214 - 225