Energy management of hybrid PV/diesel/battery systems: A modified flow direction algorithm for optimal sizing design - A case study in Luxor, Egypt

被引:11
|
作者
Elfatah, Atef A. [1 ]
Hashim, Fatma A. [2 ,3 ]
Mostafa, Reham R. [4 ,5 ]
Abd El-Sattar, Hoda [6 ]
Kamel, Salah [1 ]
机构
[1] Aswan Univ, Fac Engn, Elect Engn Dept, Aswan 81542, Egypt
[2] Helwan Univ, Fac Engn, Helwan, Egypt
[3] Middle East Univ, MEU Res Unit, Amman 11831, Jordan
[4] Univ Sharjah, Res Inst Sci & Engn RISE, Sharjah 27272, U Arab Emirates
[5] Mansoura Univ, Fac Comp & Informat Sci, Informat Syst Dept, Mansoura 35516, Egypt
[6] Luxor Higher Inst Engn & Technol, Elect Engn Dept, Luxor 85834, Egypt
关键词
Optimal sizing components; Solar PV; Diesel generators (DG); Battery bank; Hybrid microgrids components; Optimization techniques; MICROGRID SYSTEM; COST-ANALYSIS; WIND; OPTIMIZATION; HYDROGEN; LOAD;
D O I
10.1016/j.renene.2023.119333
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hybrid systems have emerged as a reliable solution to meet the increasing demand loads in various fields and address the electricity shortage in remote areas. Consequently, research efforts have been directed towards determining the optimal sizing of hybrid system components to cater to different areas' demand loads. Effective energy management of hybrid micro-grid components is essential to ensure the delivery of high-quality and cost-effective power supply globally. Various optimization techniques have been employed to achieve this objective and determine optimal solutions. This paper proposes an improved version of the Flow Direction Algorithm (FDA), named mFDA, to determine the optimal sizing of a standalone system comprising solar panels, a diesel generator (DG), and a battery bank to meet the demand load in Luxor, Egypt. The primary objective of this research is to reduce the cost of energy (COE) of the system, the net present cost (NPC) of the proposed hybrid power system, the probability of a power supply loss (LPSP), and the size of a microgrid's components. The proposed methodology aims to provide an effective solution to optimize the hybrid system's performance and energy management, which can be applied in other regions as well. To achieve economic energy with high quality and effective sizing with the lowest annual cost in the shortest amount of time, Results from the proposed mFDA are evaluated with those from the original (FDA), Grey Wolf Optimizer (GWO), Gorilla Troops Optimizer (GTO), a new Optimization technique based on COOT Bird Natural Life Model (COOT), and Smell Agent Optimization (SAO) algorithm. The MATLAB program's simulation results indicate that the proposed modified mFDA algorithm performs better than other algorithms when it comes to designing hybrid microgrid component sizing. After 44 iterations, the mFDA approach demonstrates stable convergence characteristics and achieves a minimum Cost of Energy (COE) of approximately 0.2658555/kWh, a Low Probability of Sustainable Power (LPSP) of 0.06555, and a Net Present Cost (NPC) of 7,767,179. The original FDA method closely follows, attaining a COE of about 0.2658555/kWh, LPSP of 0.06555, and NPC of 7,767,179.
引用
收藏
页数:19
相关论文
共 46 条
  • [21] Optimal sizing of behind-the-meter battery energy storage systems under optimal battery operation: A case study in Ireland
    Rezaeimozafar, Mostafa
    Barrett, Enda
    Monaghan, Rory F. D.
    Duffy, Maeve
    JOURNAL OF ENERGY STORAGE, 2024, 87
  • [22] Techno-economic assessment of PV-diesel-battery hybrid systems for poultry farms: A case study in North Carolina
    Wang, Weimin
    Simonson, David
    ENERGY NEXUS, 2025, 17
  • [23] Design of Hybrid PV/Diesel Generator Systems at Minimum Cost: Case study for Kuching, Malaysia
    Mohamed, Azah
    Khatib, Tamer
    2012 IEEE PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2012,
  • [24] Optimal Design of a Hybrid PV Solar/Micro-Hydro/Diesel/Battery Energy System for a Remote Rural Village under Tropical Climate Conditions
    Oladigbolu, Jamiu Omotayo
    Ramli, Makbul A. M.
    Al-Turki, Yusuf A.
    ELECTRONICS, 2020, 9 (09) : 1 - 22
  • [25] Optimal Design and Energy Management for Hybrid Wind-Solar PV based Renewable Energy System with Battery Storage: A Review
    Srinivas, D.
    Ramesh, K.
    Ganesh, V
    2019 8TH IEEE INTERNATIONAL CONFERENCE ON COMPUTATION OF POWER, ENERGY, INFORMATION AND COMMUNICATION (ICCPEIC'19), 2019, : 155 - 160
  • [26] Optimal Design and Management of Isolated Hybrid Renewable Energy System (WT/PV/ORES) A Case Study of Kish Island
    Shahinzadeh, Hossein
    Fathi, S. Hamid
    Gheiratmand, Alireza
    Moradi, Jalal
    2016 21ST CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2016, : 208 - 215
  • [27] A novel framework for optimal design of hybrid renewable energy-based autonomous energy systems: A case study for Namin, Iran
    Maleki, Akbar
    Pourfayaz, Fathollah
    Rosen, Marc A.
    ENERGY, 2016, 98 : 168 - 180
  • [28] Resilience-centered optimal sizing and scheduling of a building-integrated PV-based energy system with hybrid adiabatic-compressed air energy storage and battery systems
    Bazdar, Elaheh
    Nasiri, Fuzhan
    Haghighat, Fariborz
    ENERGY, 2024, 308
  • [29] Feasibility and optimal sizing analysis of stand-alone hybrid energy systems coupled with various battery technologies: A case study of Pelee Island
    Babaei, Reza
    Ting, David S-K
    Carriveau, Rupp
    ENERGY REPORTS, 2022, 8 : 4747 - 4762
  • [30] Modified Farmland Fertility Optimization Algorithm for Optimal Design of a Grid-connected Hybrid Renewable Energy System with Fuel Cell Storage: Case Study of Ataka, Egypt
    Diab, Ahmed A. Zaki
    EL-Ajmi, Sultan, I
    Sultan, Hamdy M.
    Hassan, Yahia B.
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2019, 10 (08) : 119 - 132