A Deployable Multifunctional Sensor for a Catheter Device for the Renal Denervation of Resistant Hypertension

被引:2
作者
Lim, Ruiqi [1 ]
Damalerio, Maria Ramona Ninfa B. [1 ]
Sikkandhar, Musafargani [1 ]
Wee, James Yap Ven [1 ]
Park, Eul Joon [2 ]
Lim, Ran Young [2 ]
Bae, In Hee [2 ]
Cheng, Ming-Yuan [1 ]
机构
[1] ASTAR, Singapore 117685, Singapore
[2] Kalos Med Inc, Suwon 16506, South Korea
关键词
Sensors; Temperature sensors; Electrodes; Catheters; Radio frequency; Immune system; Force sensors; Catheter; contact force sensor; flexible printed circuit board (FPCB); microelectromechanical system (MEMS); renal denervation (RDN); temperature sensor; BLOOD-PRESSURE; THERAPY; DIAGNOSIS; SAFETY;
D O I
10.1109/JSEN.2023.3309320
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This study developed a deployable multimodal and multifunctional sensor for a catheter device for renal denervation (RDN) procedures to treat resistant hypertension. The catheter device has three deployable spines. When the device is deployed, it can be used to perform ablation of the renal nerve, detect the contact force exerted by the device on the renal artery wall, measure the temperature of the ablation sites, and provide feedback to control the ablation power. Each spine comprises a microelectromechanical system (MEMS) multimodal sensor chip, contact force sensor, 100-mu m-thick tungsten foil for radiopacity, and shape memory alloy spine. The MEMS chip has a platinum-based resistance temperature detector (Pt RTD) integrated with a radio frequency (RF)-powered heating electrode. It can withstand 32 ablation cycles with an RF generator setting of 8 W for 60 s per ablation cycle. An ex vivo ablation study demonstrated that an RF power range of 1-1.5 W achieved optimal ablation lesions. The Pt RTD or temperature sensor has a sensing range of 25 degrees C-94 degrees C and sensing response time of <0.5 s. The contact force sensor has a sensing range of 50-500 mN, with a minimum resolution of 50 mN and hysteresis error of 0.7 k Omega. In benchtop studies, the force sensor performed well during catheter deployment under three conditions: in air, in a hollow tube, and in saline solution. During catheter activation, the force sensor can detect the contact force between the tube wall and force-sensor module. The force-sensor resistance readout is consistent for both the hollow tube and saline solution.
引用
收藏
页码:25401 / 25410
页数:10
相关论文
共 30 条
  • [1] Comparison of new-generation renal artery denervation systems: assessing lesion size and thermodynamics using a thermochromic liquid crystal phantom model
    Al Raisi, Sara I.
    Barry, Michael T.
    Qian, Pierre
    Bhaskaran, Abhishek
    Pouliopoulos, Jim
    Kovoor, Pramesh
    [J]. EUROINTERVENTION, 2017, 13 (10) : 1242 - 1247
  • [2] Resistant hypertension: A clinical syndrome in search of a definition
    Alderman, Michael H.
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (09) : 965 - 966
  • [3] Patients with resistant hypertension
    Amar, Jacques
    [J]. JOURNAL OF HYPERTENSION, 2007, 25 : S3 - S6
  • [4] Resistant hypertension: Diagnosis, evaluation, and treatment - A scientific statement from the American Heart Association Professional Education Committee of the Council for High Blood Pressure Research (Reprinted from Hypertension, vol 51, pg 1403-1419, 2008)
    Calhoun, David A.
    Jones, Daniel
    Textor, Stephen
    Goff, David C.
    Murphy, Timothy P.
    Toto, Robert D.
    White, Anthony
    Cushman, William C.
    White, William
    Sica, Domenic
    Ferdinand, Keith
    Giles, Thomas D.
    Falkner, Bonita
    Carey, Robert M.
    [J]. CIRCULATION, 2008, 117 (25) : E510 - E526
  • [5] CARDIOVASCULAR EFFECTS OF DIRECT STIMULATION OF THE CAROTID SINUS NERVE IN MAN
    CARLSTEN, A
    FOLKOW, B
    GRIMBY, G
    HAMBERGER, CA
    THULESIUS, O
    [J]. ACTA PHYSIOLOGICA SCANDINAVICA, 1958, 44 (02): : 138 - 145
  • [6] Epstein Murray, 2007, J Clin Hypertens (Greenwich), V9, P2, DOI 10.1111/j.1524-6175.2007.06171.x
  • [7] Common Secondary Causes of Resistant Hypertension and Rational for Treatment
    Faselis, Charles
    Doumas, Michael
    Papademetriou, Vasilios
    [J]. INTERNATIONAL JOURNAL OF HYPERTENSION, 2011, 2011
  • [8] Resistant hypertension revisited: A comparison of two university-based cohorts
    Garg, JP
    Elliott, WJ
    Folker, A
    Izhar, M
    Black, HR
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (05) : 619 - 626
  • [9] Impedance characterization, degradation, and in vitro biocompatibility for platinum electrodes on BioMEMS
    Geninatti, Thomas
    Bruno, Giacomo
    Barile, Bernardo
    Hood, R. Lyle
    Farina, Marco
    Schmulen, Jeffrey
    Canavese, Giancarlo
    Grattoni, Alessandro
    [J]. BIOMEDICAL MICRODEVICES, 2015, 17 (01) : 1 - 11
  • [10] Temperature detection system for Renal Denervation Catheter application
    Gourikutty, Sajay Bhuvanendran Nair
    Choong, David
    Lim, Ruiqi
    Damalerio, Maria Ramona Ninfa Bautista
    Oh, Jungsoo
    Kim, Yuri
    Bae, Inhee
    Cheng, Ming-Yuan
    [J]. 2020 IEEE 22ND ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE (EPTC), 2020, : 198 - 202