Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures

被引:4
|
作者
Nan, Chong [1 ]
Li, Yanjun [1 ]
Liu, Yuxiu [2 ]
Ma, Liang [1 ]
Ma, Zhanbei [1 ]
机构
[1] Baoding 1 Cent Hosp, Dept Orthoped, Baoding, Hebei, Peoples R China
[2] Baoding 1 Cent Hosp, Dept Neurosurg, Baoding, Hebei, Peoples R China
关键词
Femoral neck system; femoral neck fractures; finite element analysis; biomechanics; FIXATION; RISK;
D O I
10.3233/THC-220267
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: The femoral neck system (FNS) has been considered as a novel strategy for femoral neck fracture. The diversity of internal fixation creates difficulties in choosing an effective option for Pauwels III type femoral neck fractures. Therefore, it is significant to investigate the biomechanical effects of FNS versus conventional approaches on bones. OBJECTIVE: To evaluate the biomechanical characteristics of FNS versus cannulated screws coupled with medial plate (CSS+MP) for the treatment of Pauwels III type femoral neck fractures. METHODS: Through three-dimensional computer software (Minics, Geomagic - Warp), the proximal femur model was rebuilt. Based on the present clinical characteristics, models of internal fixation were reconstructed in SolidWorks, including cannulated screws (CSS), medial plate (MP) and FNS. After parameter setting and meshing, boundary conditions and loads were set up for the final mechanical calculation in Ansys Software. Under identical experimental conditions, such as the same Pauwels angle and force loading, the peak values of displacement, shear stress and equivalent (von Mises) stress were recorded. RESULTS: This study showed that the displacement of the models was CSS, CSS+MP, and FNS in descending order of magnitude. The shear stress and equivalent stress of the models was CSS +MP, FNS, and CSS in descending order. The principal shear stress of CSS+MP was concentrated on the medial plate. The equivalent stress of FNS was more dispersed and distributed from the proximal main nail to the distal locking screw. CONCLUSION: CSS+MP and FNS exhibited better initial stability compared to CSS. However, the MP was subjected to more shear stress, which could increase the risk of internal fixation failure. Due to its unique design, FNS may be a good choice for the treatment of Pauwels III type femoral neck fractures.
引用
收藏
页码:1161 / 1170
页数:10
相关论文
共 50 条
  • [41] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Yoram A. Weil
    Feras Qawasmi
    Meir Liebergall
    Rami Mosheiff
    Amal Khoury
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 661 - 667
  • [42] Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures
    Weil, Yoram A.
    Qawasmi, Feras
    Liebergall, Meir
    Mosheiff, Rami
    Khoury, Amal
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (05) : 661 - 667
  • [43] Comparison of the clinical efficacy of a femoral neck system versus cannulated screws in the treatment of femoral neck fracture in young adults
    Changjun He
    Yao Lu
    Qian Wang
    Cheng Ren
    Ming Li
    Mingyi Yang
    Yibo Xu
    Zhong Li
    Kun Zhang
    Teng Ma
    BMC Musculoskeletal Disorders, 22
  • [44] Comparison of the clinical efficacy of a femoral neck system versus cannulated screws in the treatment of femoral neck fracture in young adults
    He, Changjun
    Lu, Yao
    Wang, Qian
    Ren, Cheng
    Li, Ming
    Yang, Mingyi
    Xu, Yibo
    Li, Zhong
    Zhang, Kun
    Ma, Teng
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [45] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Chong Nan
    Liang Ma
    Yuechuang Liang
    Yanjun Li
    Zhanbei Ma
    BMC Musculoskeletal Disorders, 23
  • [46] Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS)
    Nan, Chong
    Ma, Liang
    Liang, Yuechuang
    Li, Yanjun
    Ma, Zhanbei
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [47] Femoral neck system (FNS) versus 4 cannulated compression screws (CCSs) in the treatment of young patients with Pauwels type III femoral neck fracture: a retrospective comparative study
    Yang Gao
    Tianle Ma
    Xiaohu Chang
    Peng Jia
    Xiaoteng Li
    Xin Tang
    Journal of Orthopaedic Surgery and Research, 20 (1)
  • [48] Comparison of femoral neck shortening after femoral neck system and cannulated cancellous screw fixation for displaced femoral neck fractures in young adults
    Zheng, Shunze
    Lin, Dongze
    Chen, Peisheng
    Lin, Chaohui
    Chen, Bin
    Zheng, Ke
    Lin, Fengfei
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (06):
  • [49] A model to evaluate Pauwels type III femoral neck fractures
    Magone, Kevin M.
    Owen, Jonas K.
    Kemker, Bernard P.
    Bloom, Oliver
    Martin, Sidney
    Atkinson, Patrick
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (03) : 310 - 317
  • [50] Finite element analysis of a new plate for Pauwels type III femoral neck fractures
    Wang, Gang
    Tang, Yong
    Wu, Xuhua
    Yang, Huilin
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (02)