Shutdown Dose Rate with Cartesian Mesh for High-Energy Nuclear Systems

被引:0
|
作者
Duarte, Nancy Granda [1 ]
Popova, Irina I. [2 ]
Iverson, Erik B. [2 ]
Gallmeier, Franz X. [2 ]
Wilson, Paul P. H. [1 ]
机构
[1] Univ Wisconsin, Dept Nucl Engn & Engn Phys, Madison, WI 53706 USA
[2] Oak Ridge Natl Lab, Spallat Neutron Source, Oak Ridge, TN 37831 USA
关键词
R2S; Rigorous Two-Step method; High-energy nuclear systems; radiation transport; VERIFICATION; ACTIVATION;
D O I
10.1080/00295450.2023.2205554
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In accelerator-driven systems, charged particles and high-energy neutrons can contribute to the production of nuclides that can persist long after the system has been shut down. These nuclides release photons that contribute to the biological dose. It is essential to quantify the biological dose as a function of time after shutdown to ensure safe working conditions for laborers during maintenance procedures. The shutdown dose rate (SDR) can be calculated with the Rigorous Two-Step (R2S) method, which includes a neutron and photon transport coupled with an activation calculation. For accelerator-driven systems, calculating SDR presents challenges related to the neutron cross-sectional data available for high-energy neutrons. A tally was implemented to collect isotope production data directly in a Monte Carlo N-Particle (MCNP) calculation. The output of this RNUCS tally is then used directly in an activation calculation, bypassing the need to use cross-section data with the neutron flux to obtain the isotope production and destruction data. A mesh-based RNUCS-R2S workflow has been developed based on this tally to calculate SDR in accelerator-driven systems. This workflow operates directly on computer-aided design geometry and supports using a meshed photon source. This workflow has been verified against a cell-based RNUCS-R2S workflow. A test problem with the essential characteristics of an accelerator-driven system was created to use in this analysis. The SDR results are within 40% of the cell-based RNUCS-R2S results. The workflow was also validated with the spallation neutron source system. Most detectors' SDR results are within 50%, with a few detectors having a significantly lower SDR result than the experimental value.
引用
收藏
页码:1747 / 1764
页数:18
相关论文
共 14 条
  • [1] Shutdown dose rate analysis with CAD geometry, Cartesian/tetrahedral mesh, and advanced variance reduction
    Biondo, Elliott D.
    Davis, Andrew
    Wilson, Paul P. H.
    FUSION ENGINEERING AND DESIGN, 2016, 106 : 77 - 84
  • [2] Sensitivity of R2Smesh shutdown dose rate results on the mesh resolution
    Lu, Peng
    Pereslavtsev, Pavel
    Fischer, Ulrich
    Wegmann, Christian
    FUSION ENGINEERING AND DESIGN, 2018, 126 : 15 - 23
  • [3] Novel approach for efficient mesh based Monte Carlo shutdown dose rate calculations
    Pereslavtsev, P.
    Fischer, U.
    Leichtle, D.
    Villari, R.
    FUSION ENGINEERING AND DESIGN, 2013, 88 (9-10) : 2719 - 2722
  • [4] Uncertainty Quantification of the Decay Gamma Source in Mesh-Based Shutdown Dose Rate Calculations
    Harb, M.
    Davis, A.
    Wilson, P. P. H.
    FUSION SCIENCE AND TECHNOLOGY, 2023, 79 (01) : 1 - 12
  • [5] MOSkin dosimetry for an ultra-high dose-rate, very high-energy electron irradiation environment at PEER
    Cayley, James
    Tan, Yaw-Ren E.
    Petasecca, Marco
    Cutajar, Dean
    Breslin, Thomas
    Rosenfeld, Anatoly
    Lerch, Michael
    FRONTIERS IN PHYSICS, 2024, 12
  • [6] Secondary radiation dose during high-energy total body irradiation
    Janiszewska, M.
    Polaczek-Grelik, K.
    Raczkowski, M.
    Szafron, B.
    Konefal, A.
    Zipper, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (05) : 459 - 466
  • [7] The High-Energy Intra-Nuclear Cascade Liege-based Residual (HEIR) nuclear data library
    Fleming, M.
    David, J-C
    Rodriguez-Sanchez, J. L.
    Fiorito, L.
    Gilbert, M.
    Stainer, T.
    ND 2019: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2020, 239
  • [8] Short-time sequential high-energy gamma photon imaging using list-mode data acquisition system for high-dose-rate brachytherapy
    Nagata, Jura
    Yamamoto, Seiichi
    Yabe, Takuya
    Yogo, Katsunori
    Nakanishi, Kohei
    Noguchi, Yumiko
    Okudaira, Kuniyasu
    Kamada, Kei
    Yoshikawa, Akira
    Kataoka, Jun
    MEDICAL PHYSICS, 2022, 49 (12) : 7703 - 7714
  • [9] ADDITIONAL DOSE ASSESSMENT FROM THE ACTIVATION OF HIGH-ENERGY LINEAR ACCELERATORS USED IN RADIATION THERAPY
    Ateia, Embarka
    Ciraj-Bjelac, Olivera
    Kovacevic, Milojko
    Belicev, Petar
    Cvetkovic, Bratislav
    Anicin, Ivan
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2008, 23 (02) : 58 - 64
  • [10] Hierarchical Carbon Composites for High-Energy/Power-Density and High-Reliability Supercapacitors with Low Aging Rate
    Chen, Cheng-Chia
    Kirana, Nindita
    Puspita, Daniel Fajar
    Patra, Jagabandhu
    Hsieh, Chien-Te
    Gandomi, Yasser Ashraf
    Lai, Hong-Zheng
    Chang, Tseng-Lung
    Tseng, Chung-Jen
    Majumder, Subhasish Basu
    Wang, Cheng-Yu
    Chang, Jeng-Kuei
    CHEMSUSCHEM, 2022, 15 (10)