Evaluation of the mechanical stability of intraocular lenses using digital image correlation

被引:1
作者
Cabeza-Gil, Iulen [1 ]
Frechilla, Javier [1 ]
Calvo, Begona [1 ,2 ]
机构
[1] Univ Zaragoza, Aragon Inst Engn Res i3A, Zaragoza, Spain
[2] Biomat & Nanomed Networking Biomed Res Ctr CIBER B, Zaragoza, Spain
基金
欧盟地平线“2020”;
关键词
HAPTIC DESIGN; DECENTRATION;
D O I
10.1038/s41598-023-36694-0
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to evaluate the mechanical stability of seven different intraocular lens (IOL) haptic designs by using digital image correlation to measure their mechanical biomarkers (axial displacement, tilt, and rotation) under quasi-static compression. The IOLs were compressed between two clamps from 11.00 up to 9.50 mm whilst a 3D deformation dataset was acquired every 0.04 mm. Results revealed that flexible and mixed IOL designs exhibited better mechanical response for smaller compression diameters compared to stiff designs. Conversely, stiff designs performed better for larger compression diameters. These findings may aid in the selection and development of more mechanically stable IOL designs.
引用
收藏
页数:10
相关论文
共 31 条
[21]   Misalignment and tilt effect on aspheric intraocular lens designs after a corneal refractive surgery [J].
Perez-Gracia, Jesus ;
Avila, Francisco J. ;
Ares, Jorge ;
Valles, Juan A. ;
Remon, Laura .
PLOS ONE, 2020, 15 (12)
[22]   Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors [J].
Perez-Gracia, Jesus ;
Varea, Alejandra ;
Ares, Jorge ;
Valles, Juan A. ;
Remon, Laura .
PLOS ONE, 2020, 15 (05)
[23]   Biomechanical Stability of Three Intraocular Lenses With Different Haptic Designs: In Silico and In Vivo Evaluation [J].
Remon, Laura ;
Cabeza-Gil, Iulen ;
Calvo, Begona ;
Poyales, Francisco ;
Garzon, Nuria .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (09) :617-624
[24]   Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling [J].
Remon, Laura ;
Siedlecki, Damian ;
Cabeza-Gil, Iulen ;
Calvo, Begona .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (03)
[25]  
Sutton MA, 2009, IMAGE CORRELATION FOR SHAPE, MOTION AND DEFORMATION MEASUREMENTS: BASIC CONCEPTS, THEORY AND APPLICATIONS, P1, DOI [10.1007/978-0-387-78747-3, 10.1007/978-0-387-78747-3_5]
[26]   Relationship between lens and capsular bag size [J].
Vasavada, A ;
Singh, R .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (04) :547-551
[27]   In-vivo high-speed biomechanical imaging of the cornea using Corvis ST and digital image correlation [J].
Wang, Bo ;
Yang, Lanting ;
Cheng, Jiaxuan ;
Wang, Junjie ;
Mei, Yue .
COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 153
[28]   Intraocular Lenses Overview of Designs, Materials, and Pathophysiologic Features [J].
Werner, Liliana .
OPHTHALMOLOGY, 2021, 128 (11) :E74-E93
[29]   Ex vivo testing of intact eye globes under inflation conditions to determine regional variation of mechanical stiffness [J].
Whitford, Charles ;
Joda, Akram ;
Jones, Steve ;
Bao, Fangjun ;
Rama, Paolo ;
Elsheikh, Ahmed .
EYE AND VISION, 2016, 3
[30]   Assessment of intraocular lens/capsular bag biomechanical interactions following cataract surgery in a human in vitro graded culture capsular bag model [J].
Wormstone, I. Michael ;
Damm, Niklas B. ;
Kelp, Martin ;
Eldred, Julie A. .
EXPERIMENTAL EYE RESEARCH, 2021, 205