Short-term effect of material type and thickness of occlusal splints on maximum bite force and sleep quality in patients with sleep bruxism: a randomized controlled clinical trial

被引:11
作者
Benli, Merve [1 ,2 ]
Ozcan, Mutlu [3 ,4 ]
机构
[1] Univ Pittsburgh, Sch Dent Med, Dept Oral Biol, Pittsburgh, PA 15213 USA
[2] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
[3] Univ Zurich, Ctr Dent Med, Div Dent Biomat, Clin Reconstruct Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
[4] Univ Zurich, Ctr Dent Med, Clin Chewing Funct Disturbances, Clin Reconstruct Dent, Plattenstr 11, CH-8032 Zurich, Switzerland
关键词
Sleep bruxism; Occlusal splints; Bite force; Sleep quality; MASTICATORY MUSCLE-ACTIVITY; MANDIBULAR ADVANCEMENT DEVICE; STABILIZATION SPLINTS; MANAGEMENT; EFFICACY; MASSETER; THERAPY; ADULTS;
D O I
10.1007/s00784-023-05049-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo evaluate the short-term effects of hard and soft splints of different thicknesses on maximum bite force (MBF) and sleep quality (SQ) in participants with sleep bruxism (SB).MethodsOne-hundred-fifteen patients were randomly allocated to five groups: Groups H2(Hard splint-2 mm), H3(Hard splint-3 mm), S2(Soft splint-2 mm), S3(Soft splint-3 mm), and C (control). Outcomes were MBF (assessed with a digital gnathodynamometer) and SQ (assessed with the Pittsburgh Sleep Quality Index). Measurements were performed at T0 (before the splints), T1 (1-month follow-up), and T2 (2-months follow-up). Data were analyzed using one-way analysis of variance(ANOVA), Tukey's HSD, and chi-square tests (alpha = 0.05).ResultsAt T1, the highest MBF values were observed in group H3 (658.01 +/- 22.6 N), while the lowest in group S2 (585.45 +/- 8.68 N). For T2, the highest values were obtained in H3 group (676.85 +/- 21.9 N), and the lowest in group S2 (565.65 +/- 10.9 N) (p < 0.05).For SQ, groups S2 and S3 revealed the lowest PSQI values at T1 (9.1; 9.6) and T2 (9; 9.5) (p < 0.001).ConclusionsThe short-term use of both 2 and 3-mm thick soft splints resulted in a decrease in MBF. Improvement in SQ in patients using soft splints was observed in the 1st month and was maintained in the 2nd month.
引用
收藏
页码:4313 / 4322
页数:10
相关论文
共 54 条
[1]  
Abekura H, 2008, INT J PROSTHODONT, V21, P116
[2]  
AHLGREN J, 1969, PRACT-OTO-RHINO-LARY, V31, P22
[3]   Evaluation of the 3mm Thickness Splint Therapy on Temporomandibular Joint Disorders (TMDs) [J].
Akbulut, Nihat ;
Altan, Ahmet ;
Akbulut, Sibel ;
Atakan, Cemal .
PAIN RESEARCH & MANAGEMENT, 2018, 2018
[4]  
Alkan Alper, 2008, Eur J Dent, V2, P276
[5]  
[Anonymous], 2014, INT CLASSIFICATION S, V3
[6]   Choice of biomaterials-Do soft occlusal splints influence jaw-muscle activity during sleep? A preliminary report [J].
Arima, Taro ;
Takeuchi, Tamiyo ;
Tomonaga, Akio ;
Yachida, Wataru ;
Ohata, Noboru ;
Svensson, Peter .
APPLIED SURFACE SCIENCE, 2012, 262 :159-162
[7]  
Buysse D J, 1989, Psychiatry Res, V28, P193
[8]   Association of sleep bruxism with oral health-related quality of life and sleep quality [J].
Camara-Souza, Mariana Barbosa ;
Costa de Figueredo, Olivia Maria ;
Matheus Rodrigues Garcia, Renata Cunha .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (01) :245-251
[9]  
Canay S, 1998, ORAL SURG ORAL MED O, V85, P674
[10]  
Castroflorio T, 2018, J Biol Regul Homeost Agents, V32, P21