Test-Retest Repeatability of Patlak Slopes versus Standardized Uptake Values for Hypermetabolic Lesions and Normal Organs in an Oncologic PET/CT Population

被引:6
作者
Ince, Semra [1 ]
Laforest, Richard [1 ]
Ashrafinia, Saeed [2 ]
Smith, Anne M. [2 ]
Wahl, Richard L. [1 ,3 ]
Fraum, Tyler J. [1 ]
机构
[1] Washington Univ, Dept Radiol, Sch Med, 510 S Kingshighway Blvd, Campus Box 8131, St Louis, MO 63110 USA
[2] Siemens Med Solut USA Inc, 810 Innovat Dr, Knoxville, TN 37932 USA
[3] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO USA
关键词
Patlak; Metabolic rate; PET; FDG; Repeatability; Test-retest; FDG; REPRODUCIBILITY; CANCER; TIME; SUV;
D O I
10.1007/s11307-024-01909-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeWe aimed to determine the test-retest repeatability of quantitative metrics based on the Patlak slope (PS) versus the standardized uptake value (SUV) among lesions and normal organs on oncologic [18F]FDG-PET/CT.ProceduresThis prospective, single-center study enrolled adults undergoing standard-of-care oncologic [18F]FDG-PET/CTs. Early (35-50 min post-injection) and late (75-90 min post-injection) SUV and PS images were reconstructed from dynamic whole-body PET data. Repeat imaging occurred within 7 days. Relevant quantitative metrics were extracted from lesions and normal organs. Repeatability was assessed via mean test-retest percent changes [T-RT %Delta], within-subject coefficients of variation (wCVs), and intra-class correlation coefficients (ICCs).ResultsNine subjects (mean age, 61.7 +/- 6.2 years; 6 females) completed the test-retest protocol. Four subjects collectively had 17 [18F]FDG-avid lesions. Lesion wCVs were higher (i.e., worse repeatability) for PS-early-max (16.2%) and PS-early-peak (15.6%) than for SUV-early-max (8.9%) and SUV-early-peak (8.1%), with similar early metric ICCs (0.95-0.98). Lesion wCVs were similar for PS-late-max (8.5%) and PS-late-peak (6.4%) relative to SUV-late-max (9.7%) and SUV-late-peak (7.2%), with similar late metric ICCs (0.93-0.98). There was a significant bias toward higher retest SUV and PS values in the lesion analysis (T-RT %Delta [95% CI]: SUV-late-max, 10.0% [2.6%, 17.0%]; PS-late-max, 20.4% [14.3%, 26.4%]) but not in the normal organ analysis.ConclusionsAmong [18F]FDG-avid lesions, the repeatability of PS-based metrics is similar to equivalent SUV-based metrics at late post-injection time points, indicating that PS-based metrics may be suitable for tracking response to oncologic therapies. However, further validation is required in light of our study's limitations, including small sample size and bias toward higher retest values for some metrics.
引用
收藏
页码:284 / 293
页数:10
相关论文
共 17 条
[1]  
Beaulieu S, 2003, J NUCL MED, V44, P1044
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Chirindel A, 2015, CLIN NUCL MED, V40, pE17, DOI 10.1097/RLU.0000000000000446
[4]   Clinical validation of a population-based input function for 20-min dynamic whole-body 18F-FDG multiparametric PET imaging [J].
Dias, Andre H. ;
Smith, Anne M. ;
Shah, Vijay ;
Pigg, David ;
Gormsen, Lars C. ;
Munk, Ole L. .
EJNMMI PHYSICS, 2022, 9 (01)
[5]  
KEYES JW, 1995, J NUCL MED, V36, P1836
[6]   The QIBA Profile for FDG PET/CT as an Imaging Biomarker Measuring Response to Cancer Therapy [J].
Kinahan, Paul E. ;
Perlman, Eric S. ;
Sunderland, John J. ;
Subramaniam, Rathan ;
Wollenweber, Scott D. ;
Turkington, Timothy G. ;
Lodge, Martin A. ;
Boellaard, Ronald ;
Obuchowski, Nancy A. ;
Wahl, Richard L. .
RADIOLOGY, 2020, 294 (03) :647-657
[7]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[8]  
KUWABARA H, 1991, J NUCL MED, V32, P692
[9]   Detection of Hepatic Metastases Using Dual-Time-Point FDG PET/CT Scans in Patients with Colorectal Cancer [J].
Lee, Jeong Won ;
Kim, Seok-Ki ;
Lee, Sang Mi ;
Moon, Seung Hwan ;
Kim, Tae-Sung .
MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (03) :565-572
[10]   LUNG-CANCER - REPRODUCIBILITY OF QUANTITATIVE MEASUREMENTS FOR EVALUATING 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE UPTAKE AT PET [J].
MINN, H ;
ZASADNY, KR ;
QUINT, LE ;
WAHL, RL .
RADIOLOGY, 1995, 196 (01) :167-173