Pelvic Fixation With a Quad-Rod Technique Using S2 Alar Iliac and Medialized Entry Iliac Screws for Long Fusion Constructs

被引:3
作者
Sherif, Sherif [1 ]
Ling, Jeremiah [1 ]
Zapolsky, Ivan
Falk, David P. [1 ]
Bondar, Kevin [2 ]
Arlet, Vincent [1 ]
Saifi, Comron [2 ]
机构
[1] Univ Penn, Dept Orthopaed Surg, Philadelphia, PA USA
[2] Houston Methodist Hosp, Dept Orthoped & Sports Med, Houston, TX 77030 USA
来源
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS | 2023年 / 7卷 / 08期
关键词
Quad Rod; Medialized Entry Iliac Screw; Adult Spinal Deformity; Sagittal imbalance; Spino-pelvic Fixation; 4-ROD TECHNIQUE; PARAMETERS; SCOLIOSIS; SURGERY;
D O I
10.5435/JAAOSGlobal-D-22-00251
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: Patients with adult spinal deformity (ASD) may have risk factors for nonunion and subsequent instrumentation failure. This study reviews a novel surgical technique for a quad-rod construct to the pelvis using both S2 alar iliac (S2AI) screw fixation and medialized entry iliac screw fixation as described through three separate cases and a review of the literature. Methods: This technique facilitates alignment of the construct and rod insertion into the tulip heads. The medialized iliac screw technique also avoids the potential soft-tissue complications of the conventional iliac screw bolt given that it is deeper and has more soft-tissue coverage. Results: Three cases performed by the most senior author (V.A.) in which this novel technique was used are presented in this report along with clinical and radiographic images to educate the reader on appropriate execution of this technique. A review of the existing literature regarding pelvic fixation techniques for ASD was also done. Conclusion: Quad-rod augmentation of long thoracolumbar spinal constructs with two independent SI anchoring points is potentially an effective technique to increase lumbar sacral construct rigidity, thereby promoting fusion rates and decreasing revision rates. The described technique provides spine surgeons with an additional tool in their armamentarium to treat patients with complex ASD.
引用
收藏
页数:13
相关论文
共 34 条
[31]  
Sponseller PD., 2009, Spine, V10, P114
[32]   Minimum 5-year analysis of L5-S1 fusion using sacropelvic fixation (bilateral S1 and iliac screws) for spinal deformity [J].
Tsuchiya, K ;
Bridwell, KH ;
Kuklo, TR ;
Lenke, LG ;
Baldus, C .
SPINE, 2006, 31 (03) :303-308
[33]   Biomechanical Effect of 4-Rod Technique on Lumbosacral Fixation An In Vitro Human Cadaveric Investigation [J].
Wang, Taiping ;
Liu, Hui ;
Zheng, Zhaomin ;
Li, Zemin ;
Wang, Jianru ;
Sen Shrivastava, Shilabant ;
Yang, Hao .
SPINE, 2013, 38 (15) :E925-E929
[34]   Long additional rod constructs can reduce the incidence of rod fractures following 3-column osteotomy with pelvic fixation in short term [J].
Yamato, Yu ;
Hasegawa, Tomohiko ;
Togawa, Daisuke ;
Yoshida, Go ;
Banno, Tomohiro ;
Arima, Hideyuki ;
Oe, Shin ;
Mihara, Yuki ;
Ushirozako, Hiroki ;
Yasuda, Tatsuya ;
Matsuyama, Yukihiro .
SPINE DEFORMITY, 2020, 8 (03) :481-490