Development and application of a miniature mass spectrometer with continuous sub-atmospheric pressure interface and integrated ionization source

被引:7
|
作者
Zhu, Yanping [1 ]
Zhang, Ruina [1 ]
Wang, Kai [1 ]
Lu, Jun [1 ]
Lin, Lin [2 ]
Yang, Lili [3 ]
Zhang, Qian [4 ]
Wang, Xiaohao [1 ]
Yu, Quan [1 ]
机构
[1] Tsinghua Univ, Shenzhen Int Grad Sch, Div Adv Mfg, Shenzhen 518055, Peoples R China
[2] Southern Univ Sci & Technol, Sustech Core Res Facil, Shenzhen 518055, Peoples R China
[3] Yanshan Univ, Sch Elect Engn, Qinhuangdao 066004, Hebei, Peoples R China
[4] China Acad Informat & Commun Technol, Informatizat & Ind Integrat Res Inst, Beijing 100191, Peoples R China
基金
中国国家自然科学基金;
关键词
PHOTOIONIZATION; SIMULATION;
D O I
10.1016/j.talanta.2022.123994
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the miniature mass spectrometer (MS) with a continuous atmospheric pressure interface (CAPI), the gas in the multi-stage chambers directly affects the performance of the instrument. In this study, a sealed ionization chamber is designed to couple with a conventional mini CAPI-MS. In this configuration, the gas environment in the first ionization chamber can be flexibly changed to regulate the gas conditions throughout the entire instrument. By studying the effect of gas pressure on the performance of the instrument, we found that the instrument shows some unique advantages when the first ionization chamber is under sub-atmospheric pressure (SAP) conditions, such as reducing the load of the vacuum pump by 40%, achieving pump-free injection for gas and liquid samples, and improving the resolution by a factor of 2 without loss of detection sensitivity. Therefore, we propose a new integrated interface called continuous sub-atmospheric pressure interface (CSAPI) for building a miniature ion trap mass spectrometer. The CSAPI specially integrates sample introduction, gas/ions interface, and ionizations, including electrospray ionization (ESI) and secondary electrospray ionization (SESI), making this system more convenient for non-professional handlers to rapidly identify or monitor target analytes in gaseous- and solution-phase samples. We also use this system to study gas composition to further improve performance, being able to achieve a 5-fold sensitivity and 2-fold resolution improvement. At last, some custom applications of the current CSAPI-MS platform are explored and demonstrated, including real-time monitoring of chemical reactions in solution and long-distance sampling and analysis of dried Chinese herbs. In conclusion, this study provides a new approach to constructing a complete, versatile and practical miniature MS instrument.
引用
收藏
页数:7
相关论文
共 15 条
  • [1] Simulated and developed an electron impact ionization source for space miniature time-of-flight mass spectrometer
    Ren, Zhengyi
    Guo, Meiru
    Cheng, Yongjun
    Sun, Wenjun
    Dong, Meng
    Li, Gang
    Pei, Xiaoqiang
    Wu, Chengyao
    VACUUM, 2020, 174
  • [2] Studies of the mechanism of the cluster formation in a thermally sampling atmospheric pressure ionization mass spectrometer
    Albrecht, Sascha
    Klopotowski, Sebastian
    Derpmann, Valerie
    Klee, Sonja
    Brockmann, Klaus J.
    Stroh, Fred
    Benter, Thorsten
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (01)
  • [3] Discontinuous Subatmospheric Pressure Interface Reduces the Gas Flow Effects on Miniature CAPI Mass Spectrometer
    Huo, Xinming
    Zhu, Xuanyu
    Tang, Fei
    Zhang, Jian
    Zhang, Xiaohua
    Yu, Quan
    Wang, Xiaohao
    ANALYTICAL CHEMISTRY, 2020, 92 (05) : 3707 - 3715
  • [4] Investigation of Atmospheric Pressure Photochemical Ionization Mass Spectra of Binary Organic Solutions without Their Separation in Dependence on the Concentration of Solutions and Analyte Vapors in Nitrogen Using the Exponential Dilution Method and a Time-of-Flight Mass Spectrometer with an Atmospheric Pressure Photochemical Ionization Ion Source
    Revelsky, I. A.
    Sysoev, A. A.
    Revelsky, A. I.
    Adamov, A. G.
    Poteshin, S. S.
    Samokhin, A. S.
    Chivarzin, M. E.
    Chepelyansky, D. A.
    Yashin, Yu. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (14) : 1743 - 1748
  • [5] Development and Application of a Chemical Ionization Focusing Integrated Ionization Source TOFMS for Online Detection of OVOCs in the Atmosphere
    Liu, Ruidong
    Guo, Yingzhe
    Li, Mei
    Li, Jing
    Yang, Dong
    Hou, Keyong
    MOLECULES, 2023, 28 (18):
  • [6] Development of a Tube Plasma Ion Source for Gas Chromatography-Mass Spectrometry Analysis and Comparison with Other Atmospheric Pressure Ionization Techniques
    Ayala-Cabrera, Juan F.
    Turkowski, Jasmin
    Uteschil, Florian
    Schmitz, Oliver J.
    ANALYTICAL CHEMISTRY, 2022, : 9595 - 9602
  • [7] Glow flow ionization mass spectrometry of small molecules. A comparison of a glow flow ionization source ('GlowFlow') with electrospray ionization and atmospheric pressure chemical ionization
    Owen, Rhodri N.
    Bajic, Stevan
    Kelly, Steven L.
    Morris, Michael R.
    Brenton, A. Gareth
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2022, 36 (15)
  • [8] Supercritical fluid chromatography coupled with in-source atmospheric pressure ionization hydrogen/deuterium exchange mass spectrometry for compound speciation
    Cho, Yunju
    Choi, Man-Ho
    Kim, Byungjoo
    Kim, Sunghwan
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1444 : 123 - 128
  • [9] Review on atmospheric pressure ionization sources for gas chromatography-mass spectrometry. Part I: Current ion source developments and improvements in ionization strategies
    Ayala-Cabrera, Juan F.
    Montero, Lidia
    Meckelmann, Sven W.
    Uteschil, Florian
    Schmitz, Oliver J.
    ANALYTICA CHIMICA ACTA, 2023, 1238
  • [10] Development of liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry for analysis of halogenated flame retardants in wastewater
    Zhou, Simon Ningsun
    Reiner, Eric J.
    Marvin, Chris
    Helm, Paul
    Riddell, Nicole
    Dorman, Frank
    Misselwitz, Michelle
    Shen, Li
    Crozier, Patrick
    MacPherson, Karen
    Brindle, Ian D.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (03) : 1311 - 1320