Economic, Exergoeconomic and Exergoenvironmental Evaluation of Gas Cycle Power Plant Based on Different Compressor Configurations

被引:1
作者
Almutairi, Hamad H. [1 ]
Almutairi, Abdulrahman S. [1 ]
Suleiman, Suleiman M. [2 ]
Alenezi, Abdulrahman H. [1 ]
Alkhulaifi, Khalid A. [1 ]
Alhajeri, Hamad M. [1 ]
机构
[1] Coll Technol Studies, Mech Power & Refrigerat Engn Technol, POB 23167, Safat 13092, Kuwait
[2] Kuwait Inst Sci Res KISR, Energy & Bldg Res Ctr, POB 24885, Safat 13109, Kuwait
关键词
gas turbine; compressor; life cycle costing; exergoeconomic; environmental indicators; EXERGY ANALYSIS; THERMODYNAMIC ANALYSIS; WASTE HEAT; OPTIMIZATION; SYSTEM; PERFORMANCE; ENGINE; ENERGY; GENERATION; WATER;
D O I
10.3390/pr11041023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The decision-making process behind the selection of a gas turbine engine (GT) is crucial and must be made in accordance with economic, environmental, and technical requirements. This paper presents the relevant economic, exergoeconomic and exergoenvironmental analyses for four GT engines with different compressor configurations. The GT engine configurations are identified according to the type of compressor: axial, axial-centrifugal, two-stage centrifugal, and centrifugal-centrifugal. The performances of the four GT engines were validated against manufacturer supplied data using specialized software. The economic analysis, a detailed life cycle costing considering the cost to be paid per unit net power obtained from the GT, and subsequent shortest payback period showed that the GT with centrifugal-centrifugal compressor was most economically feasible. This was followed, in order, by the GT-axial, GT-axial-centrifugal, and finally the GT-two-stage centrifugal configuration, where the cost of ownership for a 20 year plan ranges between 8000 USD/kW to about 12,000 USD/kW at different operational scenarios during the life cycle costing. Exergoeconomic assessment provided useful information to enhance the cost-effectiveness of all four systems by evaluating each component separately. The axial-centrifugal configuration registered the lowest CO2 emissions (about 0.7 kg/kWh); all environmental indicators confirmed it is the most environmentally friendly option.
引用
收藏
页数:20
相关论文
共 44 条
[1]  
Abam F.I., 2012, J EMERG TRENDS ENG A, V3, P131
[2]   Multi-objective exergy-based optimization of a polygeneration energy system using an evolutionary algorithm [J].
Ahmadi, Pouria ;
Rosen, Marc A. ;
Dincer, Ibrahim .
ENERGY, 2012, 46 (01) :21-31
[3]  
Al-Doori W., 2012, INT J RECENT RES APP, V13, P549
[4]  
Almutairi A., 2016, AM J ENERGY RES, V4, P1, DOI [10.12691/ajer- 4-1-1, DOI 10.12691/AJER-4-1-1, 10.12691/ajer-4-1-1]
[5]   Thermal performance analysis of gas turbine engines based on different compressor configurations [J].
Almutairi, Abdulrahman ;
Zedan, Mohamed ;
Alhajeri, Hamad M. ;
Alenezi, Abdulrahman .
HEAT TRANSFER, 2020, 49 (05) :2717-2745
[6]   Exergetic and Sustainability Analysis of an Intercooled Gas Turbine Cogeneration Plant with Reverse Osmosis Desalination System [J].
Almutairi, Abdulrahman ;
Pilidis, Pericles ;
Al-Mutawa, Nawaf ;
Al-Weshahi, Mohammed .
JOURNAL OF ENERGY ENGINEERING, 2017, 143 (05)
[7]   A techno-economic analysis of PV solar modules attached to vertical facades of a residential building in a hot arid climate [J].
Almutairi, Hamad H. ;
Alajmi, Ali F. ;
Ahmed, Nabil A. .
JOURNAL OF ENGINEERING RESEARCH, 2022, 10 (3B) :108-123
[8]  
[Anonymous], Global Status Report 2014 (Renewable Energy Policy Network for the 21st Century)
[9]  
Arora Rajesh, 2020, International Journal of Energy Technology and Policy, V16, P327
[10]   Exergy and exergo-economic analysis and optimization of a solar double pressure organic Rankine cycle [J].
Ashouri, Milad ;
Ahmadi, Mohammad H. ;
Pourkiaei, S. Mohsen ;
Astaraei, Fatemeh Razi ;
Ghasempour, Roghaye ;
Ming, Tingzhen ;
Hemati, Javid Haj .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2018, 6 :72-86