A Versatile In-Ear Biosensing System and Body-Area Network for Unobtrusive Continuous Health Monitoring

被引:18
作者
Paul, Akshay [1 ]
Lee, Min S. [1 ]
Xu, Yuchen [1 ]
Deiss, Stephen R. [1 ]
Cauwenberghs, Gert [1 ]
机构
[1] Univ Calif San Diego, Shu Chien Gene Lay Dept Bioengn, San Diego, CA 92093 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
BCI; body sensor network; dry electrodes; EMG; EOG; health sensing; in-ear EEG; PCB electrodes; WiFi; EEG;
D O I
10.1109/TBCAS.2023.3272649
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To enable continuous, mobile health monitoring, body-worn sensors need to offer comparable performance to clinical devices in a lightweight, unobtrusive package. This work presents a complete versatile wireless electrophysiology data acquisition system (weDAQ) that is demonstrated for in-ear electroencephalography (EEG) and other on-body electrophysiology with user-generic dry-contact electrodes made from standard printed circuit boards (PCBs). Each weDAQ device provides 16 recording channels, driven right leg (DRL), a 3-axis accelerometer, local data storage, and adaptable data transmission modes. The weDAQ wireless interface supports deployment of a body area network (BAN) capable of aggregating various biosignal streams over multiple worn devices simultaneously, on the 802.11n WiFi protocol. Each channel resolves biopotentials ranging over 5 orders of magnitude with a noise level of 0.52 mu V-rms over a 1000-Hz bandwidth, and a peak SNDR of 119 dB and CMRR of 111 dB at 2 ksps. The device leverages in-band impedance scanning and an input multiplexer to dynamically select good skin contacting electrodes for reference and sensing channels. In-ear and forehead EEG measurements taken from subjects captured modulation of alpha brain activity, electrooculogram (EOG) characteristic eye movements, and electromyogram (EMG) from jaw muscles. Simultaneous ECG and EMG measurements were demonstrated on multiple, freely-moving subjects in their natural office environment during periods of rest and exercise. The small footprint, performance, and configurability of the open-source weDAQ platform and scalable PCB electrodes presented, aim to provide the biosensing community greater experimental flexibility and lower the barrier to entry for new health monitoring research.
引用
收藏
页码:483 / 494
页数:12
相关论文
共 51 条
[1]  
Akinin A., 2020, Neural Engineering, P65
[2]  
An HS, 2016, INT WINT WORKSH BR
[3]  
Bertelsen AR, 2019, IEEE ENG MED BIO, P5613, DOI [10.1109/EMBC.2019.8857351, 10.1109/embc.2019.8857351]
[4]  
Biswas S., 2022, TRANSPORT ENG, V11
[5]   SPECTRA OF AUDITORY BRAIN-STEM RESPONSES AND SPONTANEOUS EEG [J].
BOSTON, JR .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (04) :334-341
[6]   Evaluation of Artifact Subspace Reconstruction for Automatic Artifact Components Removal in Multi-Channel EEG Recordings [J].
Chang, Chi-Yuan ;
Hsu, Sheng-Hsiou ;
Pion-Tonachini, Luca ;
Jung, Tzyy-Ping .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (04) :1114-1121
[7]   Micropower Non-contact EEG Electrode with Active Common-Mode Noise Suppression and Input Capacitance Cancellation [J].
Chi, Yu M. ;
Cauwenberghs, Gert .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :4218-+
[8]  
Chi Yu Mike, 2010, IEEE Rev Biomed Eng, V3, P106, DOI 10.1109/RBME.2010.2084078
[9]   Dry and Noncontact EEG Sensors for Mobile Brain-Computer Interfaces [J].
Chi, Yu Mike ;
Wang, Yu-Te ;
Wang, Yijun ;
Maier, Christoph ;
Jung, Tzyy-Ping ;
Cauwenberghs, Gert .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2012, 20 (02) :228-235
[10]   EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis [J].
Delorme, A ;
Makeig, S .
JOURNAL OF NEUROSCIENCE METHODS, 2004, 134 (01) :9-21