Electrochemical detection of lead and cadmium ions in water by sensors based on modified track-etched membranes

被引:13
作者
Zhumanazar, Nurdaulet [1 ,2 ]
Korolkov, Ilya V. [1 ,2 ]
Yeszhanov, Arman B. [1 ,2 ]
Shlimas, Dmitriy I. [1 ,2 ]
Zdorovets, Maxim V. [1 ,2 ,3 ]
机构
[1] Inst Nucl Phys, Ibragimov Str 1, Alma Ata 050032, Kazakhstan
[2] LN Gumilyov Eurasian Natl Univ, Satpaev Str 2, Nur Sultan 010008, Kazakhstan
[3] Ural Fed Univ, Mira Str 19, Ekaterinburg 620002, Russia
关键词
Track-etched membranes; Photograft polymerization; Electrochemical sensing; Lead cadmium detection; Stripping voltammetry; HEAVY-METAL IONS; VOLTAMMETRIC DETERMINATION; GRAPHENE OXIDE; ELECTRODE; NANOPARTICLES; BIOSENSORS; SILICA; PVDF; 17-BETA-ESTRADIOL; PRECONCENTRATION;
D O I
10.1016/j.sna.2022.114094
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrochemical sensors based on PET track-etched membranes (TeMs) were prepared by photograft polymeri-zation of 2-hydroxyethylmethacrylate (HEMA) and subsequent formation of interpolyelectrolyte complexes with poly(allylamine) (PAlAm). The functionalized TeMs were characterized by scanning electron microscopy (SEM), FTIR spectroscopy, gas permeability and colorimetric assay. Parameters of graft polymerization such as monomer concentration, time of irradiation, solvent and others were estimated and optimized. Cd(II) and Pb(II) ions were detected by using square wave anodic stripping voltammetry (SW-ASV). Additional modification of the modified membranes with 4-mercaptophenylboronic acid (MPBA) led to increasing of stability of the sensors. The linear range for the detection of Cd(II) and Pb(II) ions using the modified electrode was 50 mu g -4.25 mg/L and 10 mu g - 4.25 mg/L. Moreover, the obtained results of SW-ASV demonstrated that the enhancement in the electrochemical signals was achieved with PET TeMs-g-PHEMA-PAlAm\MPBA compared to that of a bare PET TeMs-g-PHEMA. Selectivity test showed that alkali and alkaline earth metal ions, except for magnesium (up to 1 mg/l), do not particularly interfere with the determination of lead and cadmium in the analyte. Sensing of Pb and Cd ions in river water demonstrate us that prepared sensors can be used in real conditions with sufficient accuracy and reproducibility of the results.
引用
收藏
页数:10
相关论文
共 60 条
[1]   Polymerization Kinetics of Poly(2-Hydroxyethyl Methacrylate) Hydrogels and Nanocomposite Materials [J].
Achilias, Dimitris S. ;
Siafaka, Panoraia I. .
PROCESSES, 2017, 5 (02)
[2]   Bio-Mimetic Sensors Based on Molecularly Imprinted Membranes [J].
Algieri, Catia ;
Drioli, Enrico ;
Guzzo, Laura ;
Donato, Laura .
SENSORS, 2014, 14 (08) :13863-13912
[3]  
[Anonymous], 2006, RISK PROFILE PERFLUO, P6
[4]  
[Anonymous], 2011, Guidelines for Drinking Water Quality, Vfourth
[5]   Voltammetric determination of 17β-estradiol in human urine and buttermilk samples using a simple copper(II) oxide-modified carbon paste electrode [J].
Antoniazzi, Cristiane ;
de Lima, Camila Alves ;
Marangoni, Rafael ;
Spinelli, Almir ;
de Castro, Eryza Guimaraes .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (05) :1373-1383
[6]   A novel electrochemical sensor based on a glassy carbon electrode modified with dendrimer functionalized magnetic graphene oxide for simultaneous determination of trace Pb(II) and Cd(II) [J].
Baghayeri, Mehdi ;
Alinezhad, Heshmatollah ;
Fayazi, Maryam ;
Tarahomi, Mehrasa ;
Ghanei-Motlagh, Reza ;
Maleki, Behrooz .
ELECTROCHIMICA ACTA, 2019, 312 :80-88
[7]   A simple approach for simultaneous detection of cadmium(II) and lead(II) based on glutathione coated magnetic nanoparticles as a highly selective electrochemical probe [J].
Baghayeri, Mehdi ;
Amiri, Amirhassan ;
Maleki, Behrooz ;
Alizadeh, Zahra ;
Reiser, Oliver .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 :1442-1450
[8]   Nanopore size tuning of polymeric membranes using the RAFT-mediated radical polymerization [J].
Barsbay, Murat ;
Guven, Olgun ;
Bessbousse, Haad ;
Wade, Travis L. ;
Beuneu, Francois ;
Clochard, Marie-Claude .
JOURNAL OF MEMBRANE SCIENCE, 2013, 445 :135-145
[9]   Poly(4-vinyl pyridine) radiografted PVDF track etched membranes as sensors for monitoring trace mercury in water [J].
Bessbousse, H. ;
Zran, N. ;
Fauleau, J. ;
Godin, B. ;
Lemee, V. ;
Wade, T. ;
Clochard, M-C. .
RADIATION PHYSICS AND CHEMISTRY, 2016, 118 :48-54
[10]   Functionalized Nanoporous Track-Etched b-PVDF Membrane Electrodes for Heavy Metal Determination by Square-Wave Anodic Stripping Voltammetry [J].
Bessbousse, H. ;
Barsbay, M. ;
Guven, O. ;
Clochard, M. -C. ;
Wade, T. L. .
PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON HEAVY METALS IN THE ENVIRONMENT, 2013, 1