Energy Consumption Analysis Using Weighted Energy Index and Energy Modeling for a Hotel Building

被引:2
作者
Permana, Indra [1 ]
Wang, Fujen [2 ]
Agharid, Alya Penta [2 ]
Rakshit, Dibakar [3 ]
Luo, Jianhui [2 ]
机构
[1] Natl Chin Yi Univ Technol, Grad Inst Precis Mfg, Taichung 411, Taiwan
[2] Natl Chin Yi Univ Technol, Dept Refrigerat Air Conditioning & Energy Engn, Taichung 411, Taiwan
[3] Indian Inst Technol Delhi, Dept Energy Sci & Engn, New Delhi 110016, India
关键词
field measurement; regression analysis; EnergyPlus; energy saving; PERFORMANCE;
D O I
10.3390/buildings13041022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Energy consumption is an essential and vital issue for commercial hotel buildings. Regulations and codes are commonly used to regulate the energy usage of the building. However, the energy index used to evaluate energy performance does not include the usage of hotel buildings for different service purposes. This study utilizes a comprehensive approach involving data collection, field measurement, regression analysis, and building energy modeling to investigate the energy performance in hotel buildings. The study finds that ambient temperature and occupancy rate are key factors in energy consumption, resulting in a weighted energy index for public areas and guest rooms with an R-square of 0.8314 and 0.9184, respectively. The measurement data are also used to perform the energy modeling, and the data are validated. Studies on different regions, occupancy, orientation, window-to-wall ratios, and U-values are evaluated and simulated to determine the energy consumption, which might be useful for the hotel building design phase. In addition, it also evaluates the energy-saving potential, including chilled and condenser water temperature, COP, and indoor temperature settings. The study finds that implementing various studies could result in significant energy consumption and savings, with higher chilled water and lower condenser water temperature having a particularly prominent impact. The study concludes that energy modeling approaches can be useful tools for identifying and implementing energy-saving strategies.
引用
收藏
页数:16
相关论文
共 29 条
[1]   Feasibility of utilizing renewable energy systems for a small hotel in Ajloun city, Jordan [J].
Aagreh, Yaser ;
Al-Ghzawi, Audai .
APPLIED ENERGY, 2013, 103 :25-31
[2]   Analysis of energy consumption and potential energy savings of an institutional building in Malaysia [J].
Ali, Siti Birkha Mohd ;
Hasanuzzaman, M. ;
Rahim, N. A. ;
Mamun, M. A. A. ;
Obaidellah, U. H. .
ALEXANDRIA ENGINEERING JOURNAL, 2021, 60 (01) :805-820
[3]   Using Co-simulation between EnergyPlus and CONTAM to evaluate recirculation-based, demand-controlled ventilation strategies in an office building [J].
Alonso, M. Justo ;
Dols, W. S. ;
Mathisen, H. M. .
BUILDING AND ENVIRONMENT, 2022, 211
[4]   Energy consumption and conservation practices in Qatar A case study of a hotel building [J].
Ayoub, Nasser ;
Musharavati, Farayi ;
Pokharel, Shaligram ;
Gabbar, Hossam A. .
ENERGY AND BUILDINGS, 2014, 84 :55-69
[6]  
Central Weather Bureau of Taiwan, US
[7]   Energy benchmarking in support of low carbon hotels: Developments, challenges, and approaches in China [J].
Chan, Wilco .
INTERNATIONAL JOURNAL OF HOSPITALITY MANAGEMENT, 2012, 31 (04) :1130-1142
[8]   An online physical-based multiple linear regression model for building's hourly cooling load prediction [J].
Chen, Sihao ;
Zhou, Xiaoqing ;
Zhou, Guang ;
Fan, Chengliang ;
Ding, Puxian ;
Chen, Qiliang .
ENERGY AND BUILDINGS, 2022, 254
[9]   Building energy performance forecasting: A multiple linear regression approach [J].
Ciulla, G. ;
D'Amico, A. .
APPLIED ENERGY, 2019, 253
[10]   Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus [J].
Feng, Fan ;
Fu, Yangyang ;
Yang, Zhiyao ;
O'Neill, Zheng .
ENERGY AND BUILDINGS, 2022, 276