Three-dimensional numerical analysis of fin-tube desiccant-coated heat exchanger for air dehumidification in tropics

被引:17
作者
Liu, M. [1 ]
Prabakaran, V. [1 ]
Bui, T. [2 ,3 ]
Cheng, G. G. [2 ,3 ]
Pang, W. [2 ]
机构
[1] Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1, Singapore 117576, Singapore
[2] Jiangsu Univ, Sch Mech Engn, Zhenjiang 212013, Peoples R China
[3] Jiangsu Univ, Inst Intelligent Flexible Mechatron, Zhenjiang 212013, Peoples R China
关键词
Desiccant-coated heat exchanger; Air dehumidification; Composite desiccant; 3-D modeling; MOISTURE TRANSFER CHARACTERISTICS; SILICA-GEL; PERFORMANCE EVALUATION;
D O I
10.1016/j.apenergy.2022.120346
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
High-performance desiccant-coated heat exchangers (DCHEs) can be employed in air-conditioning systems to improve energy efficiency. While there are significant developments in experimental studies, theoretical ap-proaches for analyzing the DCHE are impeded by the complex and coupled heat and mass transport mechanisms. Therefore, a 3D mathematical model has been developed in this work to study the dehumidification performance of a DCHE. Unlike other works reported in the literature, the developed model is able to simulate the complex coupling between heat and mass transfers in the entire volume of the heat exchanger. The model is calibrated and validated with experimental data, and a maximum discrepancy of +/- 8 % is recorded. A time-dependent study on the performance of the DCHE is carried out to understand the distribution of temperature, reaction rates, and water uptake in the heat exchanger. Effects of key influencing operational factors are investigated and discussed. It is indicated that the DCHE enters a stable performance state regardless of its initial adsorption state. The regeneration time should be equal to the dehumidification time to optimize the performance. A higher thermal COP is achieved under lower cooling/regeneration temperature, lower air flowrate, and shorter half-cycle time, while higher inlet air humidity ratio. Higher coated desiccant mass also provides a higher thermal COP, but this enhancement levels off once the coating grows. For DCHEs with less coating, reducing cycle time is recom-mended over increasing the coating amount.
引用
收藏
页数:16
相关论文
共 38 条
[1]   Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers [J].
Ahmadi, Behnam ;
Ahmadi, Masoud ;
Nawaz, Kashif ;
Momen, Ayyoub M. ;
Bigham, Sajjad .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 132 :21-29
[2]   Effect of hygroscopic materials on water vapor permeation and dehumidification performance of poly( vinyl alcohol) membranes [J].
Bui, T. D. ;
Wong, Y. ;
Thu, K. ;
Oh, S. J. ;
Ja, M. Kum ;
Ng, K. C. ;
Raisul, I. ;
Chua, K. J. .
JOURNAL OF APPLIED POLYMER SCIENCE, 2017, 134 (17)
[3]   Effects of process air conditions and switching cycle period on dehumidification performance of desiccant-coated heat exchangers [J].
Chang, Chih-Chang ;
Luo, Win-Jet ;
Lu, Chi-Wen ;
Cheng, Yu-Sheng ;
Tsai, Bo-Yi ;
Lin, Zhi-Hua .
SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (01) :81-90
[4]   Energy improvement and performance prediction of desiccant coated dehumidifiers based on dimensional and scaling analysis [J].
Chen, W. D. ;
Vivekh, P. ;
Liu, M. Z. ;
Kumja, M. ;
Chua, K. J. .
APPLIED ENERGY, 2021, 303 (303)
[5]   Sorption and regeneration performance of novel solid desiccant based on PVA-LiCl electrospun nanofibrous membrane [J].
Dai, Li ;
Yao, Ye ;
Jiang, Fengjing ;
Yang, Xueqi ;
Zhou, Xinjie ;
Xiong, Peng .
POLYMER TESTING, 2017, 64 :242-249
[6]   Water vapor permeation and dehumidification performance of poly (vinyl alcohol)/lithium chloride composite membranes [J].
Duc Thuan Bui ;
Nida, Aqdas ;
Ng, Kim Choon ;
Chua, Kian Jon .
JOURNAL OF MEMBRANE SCIENCE, 2016, 498 :254-262
[7]   Experimental study on performance of silica gel and potassium formate composite desiccant coated heat exchanger [J].
Ge, T. S. ;
Zhang, J. Y. ;
Dai, Y. J. ;
Wang, R. Z. .
ENERGY, 2017, 141 :149-158
[8]   Performance study of silica gel coated fin-tube heat exchanger cooling system based on a developed mathematical model [J].
Ge, T. S. ;
Dai, Y. J. ;
Wang, R. Z. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (06) :2329-2338
[9]   Experimental comparison and analysis on silica gel and polymer coated fin-tube heat exchangers [J].
Ge, T. S. ;
Dai, Y. J. ;
Wang, R. Z. ;
Peng, Z. Z. .
ENERGY, 2010, 35 (07) :2893-2900
[10]   Isosteric Heat: Comparative Study between Clausius-Clapeyron, CSK and Adsorption Calorimetry Methods [J].
Giraldo, Liliana ;
Rodriguez-Estupinan, Paola ;
Carlos Moreno-Pirajan, Juan .
PROCESSES, 2019, 7 (04)