Value of HAVOC and Brown ESUS-AF scores for atrial fibrillation on implantable cardiac monitors after embolic stroke of undetermined source

被引:4
|
作者
Grygorowicz, Claire [1 ]
Benali, Karim [2 ]
Serzian, Guillaume [3 ]
Mouhat, Basile [3 ]
Duloquin, Gauthier [4 ,5 ]
Pommier, Thibaut [1 ,4 ]
Didier, Romain [1 ,4 ]
Laurent, Gabriel [1 ,4 ]
Bejot, Yannick [4 ,5 ]
Maille, Baptiste [6 ]
Vuillier, Fabrice [7 ]
Badoz, Marc [3 ]
Guenancia, Charles [1 ,4 ,8 ]
机构
[1] Univ Hosp, Cardiol Dept, Dijon, France
[2] Univ Hosp, Cardiol Dept, St Etienne, France
[3] Univ Hosp, Cardiol Dept, Besancon, France
[4] Univ Burgundy & Franche Comte, PEC2 EA7460, Dijon, France
[5] Univ Hosp, Neurol Dept, Dijon, France
[6] Univ Hosp, Cardiol Dept, Marseille, France
[7] Univ Hosp, Neurol Dept, Besancon, France
[8] Univ Hosp, Cardiol Dept, 14 rue Paul Gaffarel, F-21079 Dijon, France
关键词
Atrial fibrillation; Stroke; Risk score; Implantable cardiac monitor; TRANSIENT ISCHEMIC ATTACK; CRYPTOGENIC STROKE; CLASSIFICATION; PREVENTION; PREDICTION;
D O I
10.1016/j.jstrokecerebrovasdis.2023.107451
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: Up to 20 % of ischemic strokes are associated with overt atrial fibrillation (AF). Furthermore, silent AF was detected by an implantable cardiac monitor (ICM) in 1 in 3 cryptogenic strokes in the CRYSTAL AF study. An ESC position paper has suggested a HAVOC score >= 4 or a Brown ESUS-AF score >= 2 as criteria for ICM implantation after cryptogenic stroke, but neither of these criteria has been developed or validated in ICM populations. We assessed the performance of HAVOC and Brown ESUS-AF scores in a cohort of ICM patients implanted after embolic stroke of undetermined source (ESUS).Methods: All patients implanted with an ICM for ESUS between February 2016 and February 2022 at two French University Hospitals were retrospectively included. Demographic data, cardiovascular risk factors, and clinical and biological data were collected after a review of electronic medical records. HAVOC and Brown ESUS-AF scores were calculated for all patients.Findings: Among the 384 patients included, 106 (27 %) developed AF during a mean follow-up of 33 months. The scores performances for predicting AF during follow-up were: HAVOC= AUC: 68.5 %, C-Index: 0.662, and Brown ESUS-AF=AUC: 72.9 %, C-index 0.712. Compared with the CHA(2)DS(2)-VASc score, only the Brown ESUS-AF score showed significant improvement in NRI/IDI. Furthermore, classifying patients according to the suggested HAVOC and Brown ESUS-AF thresholds, only 24 % and 31 % of the cohort, respectively, would have received an ICM, and 58 (55 %) and 47 (44 %) of the AF patients, respectively, would not have been implanted with an ICM.Conclusion: HAVOC and Brown ESUS-AF scores showed close and moderate performance in predicting AF on ICM after cryptogenic stroke, with a significant lack of sensitivity. Specific risk scores should be developed and validated in large ICM cohorts.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Association between Bilateral Infarcts Pattern and Detection of Occult Atrial Fibrillation in Embolic Stroke of Undetermined Source (ESUS) Patients with Insertable Cardiac Monitor (ICM)
    Yushan, Boi
    Tan, Benjamin Y. Q.
    Ngiam, Nicholas Jinghao
    Chan, Bernard P. L.
    Luen, Teoh Hock
    Sharma, Vijay K.
    Sia, Ching-Hui
    Dalakoti, Mayank
    Chong, Seow Swee
    Kojodjojo, Pipin
    Yeo, Leonard L. L.
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2019, 28 (09) : 2448 - 2452
  • [42] Carotid plaques and detection of atrial fibrillation in embolic stroke of undetermined source
    Ntaios, George
    Perlepe, Kalliopi
    Sirimarco, Gaia
    Strambo, Davide
    Eskandari, Ashraf
    Karagkiozi, Efstathia
    Vemmou, Anastasia
    Koroboki, Eleni
    Manios, Efstathios
    Makaritsis, Konstantinos
    Michel, Patrik
    Vemmos, Konstantinos
    NEUROLOGY, 2019, 92 (23) : E2644 - E2652
  • [43] Statement by a Working Group conceived by the Polish National Consultants in Cardiology and Neurology addressing the use of implantable cardiac monitors in patients after ischaemic embolic stroke of undetermined source
    Farkowski, Michal M.
    Karlinski, Michal A.
    Kazmierczak, Jaroslaw
    Kulakowski, Piotr
    Mitkowski, Przemyslaw
    Ptaszynski, Pawel
    Ryglewicz, Danuta
    Slawek, Jaroslaw
    Slowik, Agnieszka
    Sterlinski, Maciej
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2019, 53 (03) : 181 - 189
  • [44] Left Atrial Diameter and Atrial Ectopic Burden in Patients with Embolic Stroke of Undetermined Source: Risk Stratification of Atrial Fibrillation with Insertable Cardiac Monitor Analysis
    Lee, Ji Hyun
    Moon, In Tae
    Cho, Youngjin
    Kim, Jun Yup
    Kang, Jihoon
    Kim, Beom Joon
    Han, Moon Ku
    Oh, Il Young
    Bae, Hee Joon
    JOURNAL OF CLINICAL NEUROLOGY, 2021, 17 (02): : 213 - 219
  • [45] Global Survey of the Frequency of Atrial Fibrillation-Associated Stroke: Embolic Stroke of Undetermined Source Global Registry
    Perera, Kanjana S.
    Vanassche, Thomas
    Bosch, Jackie
    Swaminathan, Balakumar
    Mundl, Hardi
    Giruparajah, Mohana
    Barboza, Miguel A.
    O'Donnell, Martin J.
    Gomez-Schneider, Maia
    Hankey, Graeme J.
    Yoon, Byung-Woo
    Roxas, Artemio, Jr.
    Lavallee, Philippa
    Sargento-Freitas, Joao
    Shamalov, Nikolay
    Brouns, Raf
    Gagliardi, Rubens J.
    Kasner, Scott E.
    Pieroni, Alessio
    Vermehren, Philipp
    Kitagawa, Kazuo
    Wang, Yongjun
    Muir, Keith
    Coutinho, Jonathan M.
    Connolly, Stuart J.
    Hart, Robert G.
    STROKE, 2016, 47 (09) : 2197 - 2202
  • [46] Cryptogenic Stroke and Embolic Stroke of Undetermined Source: Risk Factors and Approaches for Detection of Atrial Fibrillation
    Rakhimova, Idaliya
    Semenova, Yuliya
    Khaibullin, Talgat
    Kuanysheva, Anargul
    Kovalchuk, Vitalii
    Abdrakhmanov, Ayan
    CURRENT CARDIOLOGY REVIEWS, 2022, 18 (04) : 55 - 68
  • [47] Atrial fibrillation after patent foramen ovale closure in patients with embolic stroke of undetermined source
    von Falkenhausen, Aenne S.
    Keidel, Linus M.
    Wischmann, Johannes
    Hoeglinger, Guenter
    Massberg, Steffen
    Kaeaeb, Stefan
    Kellert, Lars
    Sinner, Moritz F.
    EUROPACE, 2024, 26 (06):
  • [48] Prevalence of Nonstenotic Carotid Plaque in Stroke Due to Atrial Fibrillation Compared to Embolic Stroke of Undetermined Source
    Siegler, James E.
    Thon, Jesse M.
    Woo, John H.
    Do, David
    Messe, Steven R.
    Cucchiara, Brett
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2019, 28 (10)
  • [49] Diagnosis of Occult Atrial Fibrillation in Patients With Embolic Stroke of an Undetermined Source Based on Left Atrial Strain
    Maqsood, Hamza
    Jumani, Laraib
    Wazir, Momna
    Raza, Samina
    Munir, Maryam
    Noor, Nabeeha
    Mehmood, Saad
    Neelam, Fnu
    Gulraiz, Azouba
    Saleem, Hamza
    CIRCULATION, 2023, 148
  • [50] Prevalence and Prognostic Value of Atrial Cardiopathy in Embolic Stroke of Undetermined Source
    Wu, Yueyang
    Yang, Xiaomeng
    Jing, Jing
    Meng, Xia
    Li, Zixiao
    Pan, Yuesong
    Jiang, Yong
    Yan, Hongyi
    Huang, Xinying
    Liu, Liping
    Zhao, Xingquan
    Wang, Yilong
    Li, Hao
    Wang, Yongjun
    CEREBROVASCULAR DISEASES, 2024, 53 (05) : 556 - 563