Assessing the Impact of Resin Type, Post-Processing Technique, and Arch Location on the Trueness and Precision of 3D-Printed Full-Arch Implant Surgical Guides

被引:8
作者
Vara, Rhea [1 ]
Lin, William [1 ]
Low, Jhi Kwan [1 ]
Smith, Derek [2 ]
Grimm, Antonio [2 ]
Calvert, Gareth [3 ]
Tadakamadla, Santosh Kumar [4 ,5 ]
Alifui-Segbaya, Frank [1 ]
Ahmed, Khaled E. [1 ]
机构
[1] Griffith Univ, Sch Med & Dent, Gold Coast, Qld 4215, Australia
[2] Griffith Univ, Adv Design & Prototyping Technol Inst, Gold Coast, Qld 4215, Australia
[3] Glasgow Dent Hosp & Sch, Glasgow G2 3JZ, Scotland
[4] La Trobe Univ, La Trobe Rural Hlth Sch, Dept Rural Clin Sci, Dent & Oral Hlth, Bendigo, Vic 3552, Australia
[5] La Trobe Univ, Violet Vines Marshman Ctr Rural Hlth Res, La Trobe Rural Hlth Sch, Bendigo, Vic 3552, Australia
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 04期
关键词
3D printing; full-arch surgical implant guides; post-processing technique; accuracy; trueness; precision; ACCURACY; SURGERY;
D O I
10.3390/app13042491
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Objective: The purpose of this study was to assess the impact of photopolymer resin type, arch location, and post-processing techniques on the trueness and precision of three-dimensionally printed (3DP) full-arch surgical implant guides. Methods: Stereolithography reference images of an upper and lower surgical guide with six drill holes from a full-mouth rehabilitation clinical case were used. The files were imported into the Asiga MAX UV slicing software (Asiga Composer) where build orientation, print resolution, and support structures were added. A digital light processing 3D printer (MAX UV, Asiga Max) was used for printing the samples. The samples assessed were printed using two different, manufacturer-validated resins, DentaGuide (n = 35) and DentaClear (n = 20). The samples were subdivided and measured based on the post-processing technique used: handwashing (n = 20), sonication (n = 25), a mix of handwashing and sonication (n = 10), and post-curing using 385 nm UVA light with nitrogen (n = 50) or without nitrogen (n = 5). The diameter of each drill hole per guide was measured using a coordinate measuring machine (Absolute Arm 7-Axis, Hexagon) and compared with the reference STL to calculate each sample's trueness (median error) and precision (interquartile range). The Mann-Whitney and Kruskal-Wallis tests were used for statistical analyses. Results: All samples demonstrated a dimensional error of <70 mu m. No significant differences (p > 0.05) were observed between upper and lower arches and between post-processing techniques using nitrogen, irrespective of the use of hand- or ultrasonic washing. In contrast, DentaClear resin was significantly (p < 0.001) more accurate with a trueness of 26 mu m and precision of 12 to 34 mu m versus the DentaGuide at -31 mu m and -54 to -17 mu m, respectively. The samples post-cured without nitrogen were significantly (p < 0.05) the least accurate of all surgical guides, with a trueness of -42 mu m and precision of -68 to -39 mu m. Conclusion: The resin type and nitrogen post-processing are parameters that can significantly impact the accuracy of surgical guides. The tolerance of 3DP surgical guides needs to account for the dimensional changes occurring during the manufacturing process to minimise implant positioning errors.
引用
收藏
页数:13
相关论文
共 34 条
[1]   Effect of Manufacturing Technique on the Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery [J].
Abduo, Jaafar ;
Lau, Douglas .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) :931-938
[2]   Effects of two Postprocessing Methods onto Surface Dimension of in-Office Fabricated Stereolithographic Implant Surgical Guides [J].
Ammoun, Rami ;
Dalal, Nishchal ;
Abdulmajeed, Aous A. ;
Deeb, George R. ;
Bencharit, Sompop .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01) :71-75
[3]   3D printed complete removable dental prostheses: a narrative review [J].
Anadioti, Eva ;
Musharbash, Leen ;
Blatz, Markus B. ;
Papavasiliou, George ;
Kamposiora, Phophi .
BMC ORAL HEALTH, 2020, 20 (01)
[4]   On different 3D printing methods and fracture performance in DCB composite specimens including structured interfaces [J].
Aranda, M. T. ;
Reinoso, J. ;
Garcia, I. G. .
THEORETICAL AND APPLIED FRACTURE MECHANICS, 2022, 122
[5]  
Bennett Gregory W, 2022, Gen Dent, V70, P18
[6]   Production tolerance of additive manufactured polymeric objects for clinical applications [J].
Braian, Michael ;
Jimbo, Ryo ;
Wennerberg, Ann .
DENTAL MATERIALS, 2016, 32 (07) :853-861
[7]   Current state of the art of computer-guided implant surgery [J].
D'haese, Jan ;
Ackhurst, Johan ;
Wismeijer, Daniel ;
De Bruyn, Hugo ;
Tahmaseb, Ali .
PERIODONTOLOGY 2000, 2017, 73 (01) :121-133
[8]   Establishing a point-of-care additive manufacturing workflow for clinical use [J].
Daoud, Georges E. ;
Pezzutti, Dante L. ;
Dolatowski, Calvin J. ;
Carrau, Ricardo L. ;
Pancake, Mary ;
Herderick, Edward ;
VanKoevering, Kyle K. .
JOURNAL OF MATERIALS RESEARCH, 2021, 36 (19) :3761-3780
[9]   Accuracy of 3-Dimensionally Printed Full-Arch Dental Models: A Systematic Review [J].
Etemad-Shahidi, Yasaman ;
Qallandar, Omel Baneen ;
Evenden, Jessica ;
Alifui-Segbaya, Frank ;
Ahmed, Khaled Elsayed .
JOURNAL OF CLINICAL MEDICINE, 2020, 9 (10) :1-18
[10]   Accuracy of surgical guides from 2 different desktop 3D printers for computed tomography-guided surgery [J].
Gjelvold, Bjorn ;
Mahmood, Deyar Jallal Hadi ;
Wennerberg, Ann .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (03) :498-503