Perceval sutureless bioprosthesis versus Perimount sutured bioprosthesis for aortic valve replacement in patients with aortic stenosis: a retrospective, propensity-matched study

被引:4
作者
Kapadia, Sharan J. [1 ]
Salmasi, Mohammed Yousuf [1 ,4 ]
Zientara, Alicja [2 ]
Roussin, Isabelle [3 ]
Quarto, Cesare [4 ]
Asimakopoulos, George [4 ]
机构
[1] Imperial Coll Sch Med, Sch Med, Exhibit Rd, London SW7 2BX, England
[2] Univ Freiburg, Dept Cardiac & Vasc Surg, Hugstetter Str 55, D-79106 Freiburg, Germany
[3] Lister Hosp, Dept Cardiol, East & North Hertfordshire NHS Trust, Coreys Mill Ln, Stevenage SG1 4AB, England
[4] Royal Brompton & Harefield NHS Fdn Trust, Dept Cardiothorac Surg, Sydney St, London SW3 6NP, England
关键词
Aortic valve stenosis; Aortic valve implantation; Sutureless aortic valve replacement; Minimally invasive aortic valve replacement; RAPID DEPLOYMENT; SURGERY;
D O I
10.1186/s13019-024-02575-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Rapid-deployment aortic valve replacement (RDAVR) is an alternative to conventional AVR (cAVR) for aortic stenosis. Benefits include a reduction in operative times, facilitation of minimal access surgery and superior haemodynamics compared to conventional valves. However, further evidence is required to inform guidelines, preferably in the form of propensity-matched studies that include mid-term follow-up data. Methods This was a single-centre, retrospective, propensity-matched cohort study comparing the Perceval and conventional Perimount Magna Ease valve for short- and mid-term clinical parameters and size-matched mid-term echocardiographic parameters (n = 102 in both groups) from 2014 to 2020. Data were extracted from a nationally managed dataset. Results There were no demographic differences between the matched groups. The Perceval group had shorter cross-clamp time (Perceval 62 [49-81] minutes; Perimount 79 [63-102] minutes, P < 0.001), shorter bypass time (Perceval 89 [74-114] minutes; Perimount 104 [84-137] minutes, P < 0.001), and more frequent minimally-invasive approaches (Perceval 28%; Perimount 5%, P < 0.001). Size-matched haemodynamics showed initially higher gradients in the Perceval group, but haemodynamics equalised at 12 + months. The Perceval group had a more favourable % change in the left ventricular posterior wall dimension at 2 + years (Perceval - 4.8 +/- 18; Perimount 17 +/- 2). Conclusions The Perceval facilitated shorter operations, which may benefit intermediate-high-risk, elderly patients with comorbidities requiring concomitant procedures. It also facilitated minimally invasive surgery. Size-matched haemodynamic performance was similar at mid-term follow-up, with the Perceval possibly better facilitating regression of left ventricular hypertrophy.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Does valve size impact hemodynamic, left ventricular mass regression, and prosthetic valve deterioration with a sutureless aortic valve? [J].
Aldea, Gabriel S. ;
Burke, Christopher R. ;
Fischlein, Theodor ;
Heimansohn, David A. ;
Haverich, Axel ;
Suri, Rakesh M. ;
Ad, Niv .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 168 (02) :502-509.e9
[2]  
Baumgartner H, 2018, EUR HEART J, V39, P1980, DOI [10.1093/eurheartj/ehx391, 10.1093/eurheartj/ehx636]
[3]   Hypo-Attenuated Leaflet Thickening and Reduced Leaflet Motion in Sutureless Bioprosthetic Aortic Valves [J].
Dalen, Magnus ;
Sartipy, Ulrik ;
Cederlund, Kerstin ;
Franco-Cereceda, Anders ;
Svensson, Anders ;
Themudo, Raquel ;
Svenarud, Peter ;
Brolin, Elin Bacsovics .
JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (08)
[4]   Aortic valve replacement in elderly with small aortic root and low body surface area; the Perceval S valve and its impact in effective orifice area [J].
Dedeilias, Panagiotis ;
Baikoussis, Nikolaos G. ;
Prappa, Efstathia ;
Asvestas, Dimitrios ;
Argiriou, Michalis ;
Charitos, Christos .
JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
[5]   Rapid Deployment Versus Conventional Bioprosthetic Valve Replacement for Aortic Stenosis [J].
Ensminger, Stephan ;
Fujita, Buntaro ;
Bauer, Timm ;
Moellmann, Helge ;
Beckmann, Andreas ;
Bekeredjian, Raffi ;
Bleiziffer, Sabine ;
Landwehr, Sandra ;
Hamm, Christian W. ;
Mohr, Friedrich W. ;
Katus, Hugo A. ;
Harringer, Wolfgang ;
Walther, Thomas ;
Frerker, Christian .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (13) :1417-1428
[6]   Hemodynamic Performance of Sutureless vs. Conventional Bioprostheses for Aortic Valve Replacement: The 1-Year Core-Lab Results of the Randomized PERSIST-AVR Trial [J].
Fischlein, Theodor ;
Caporali, Elena ;
Asch, Federico M. ;
Vogt, Ferdinand ;
Pollari, Francesco ;
Folliguet, Thierry ;
Kappert, Utz ;
Meuris, Bart ;
Shrestha, Malakh L. ;
Roselli, Eric E. ;
Bonaros, Nikolaos ;
Fabre, Olivier ;
Corbi, Pierre ;
Troise, Giovanni ;
Andreas, Martin ;
Pinaud, Frederic ;
Pfeiffer, Steffen ;
Kueri, Sami ;
Tan, Erwin ;
Voisine, Pierre ;
Girdauskas, Evaldas ;
Rega, Filip ;
Garcia-Puente, Julio ;
De Kerchove, Laurent ;
Lorusso, Roberto .
FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
[7]  
Fischlein T, 2021, J THORAC CARDIOV SUR, V161, P920, DOI 10.1016/j.jtcvs.2020.11.162
[8]   Sutureless, rapid deployment valves and stented bioprosthesis in aortic valve replacement: recommendations of an International Expert Consensus Panel [J].
Gersak, Borut ;
Fischlein, Theodor ;
Folliguet, Thierry A. ;
Meuris, Bart ;
Teoh, Kevin H. T. ;
Moten, Simon C. ;
Solinas, Marco ;
Miceli, Antonio ;
Oberwalder, Peter J. ;
Rambaldini, Manfredo ;
Bhatnagar, Gopal ;
Borger, Michael A. ;
Bouchard, Denis ;
Bouchot, Olivier ;
Clark, Stephen C. ;
Dapunt, Otto E. ;
Ferrarini, Matteo ;
Laufer, Guenther ;
Mignosa, Carmelo ;
Millner, Russell ;
Noirhomme, Philippe ;
Pfeiffer, Steffen ;
Ruyra-Baliarda, Xavier ;
Shrestha, Malakh ;
Suri, Rakesh M. ;
Troise, Giovanni ;
Diegeler, Anno ;
Laborde, Francois ;
Laskar, Marc ;
Najm, Hani K. ;
Glauber, Mattia .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (03) :709-718
[9]   Sutureless versus Conventional Aortic Valve Replacement: Outcomes in 70 High-Risk Patients Undergoing Concomitant Cardiac Procedures [J].
Hanedan, Muhammet Onur ;
Yuruk, Mehmet Ali ;
Parlar, Ali Ihsan ;
Ziyrek, Ugur ;
Arslan, Ali Kemal ;
Sayar, Ufuk ;
Mataraci, Ilker .
TEXAS HEART INSTITUTE JOURNAL, 2018, 45 (01) :11-16
[10]  
Kueri S, 2022, The hemodynamic performance of the Perceval Sutureless Aortic Valve in a propensity-matched comparison to the Carpentier-Edwards Perimount and Perimount magna ease valves for aortic valve replacement