Comparison of primary stability of used and unused self-tapping and self-drilling orthodontic mini-implants

被引:1
作者
Baser, Baris [1 ]
Ozel, Mehmet Birol [2 ]
机构
[1] Karadeniz Tech Univ, Fac Dent, Dept Orthodont, Trabzon, Turkiye
[2] Kocaeli Univ, Fac Dent, Dept Orthodont, Izmit, Turkiye
来源
ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE | 2024年 / 33卷 / 05期
关键词
in vitro; self-tapping; primer stability; self-drilling; orthodontic mini-implant; PULL-OUT STRENGTH; MINISCREW IMPLANTS; SKELETAL ANCHORAGE; INSERTION TORQUE; CONTACT; SCREW; REUSE; OSSEOINTEGRATION; THICKNESS; DENSITY;
D O I
10.17219/acem/169511
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background. Skeletal anchorage has been the subject of study for many years. Recently, orthodontic mini-implants (MIs) were described as effective tools for anchorage and were named temporary anchorage devices (TADs). The success of MIs depends on their primary stability, which is defined as the lack of mobility in the bone after implant insertion, and the relevant factors affecting primary stability. Objectives. This study aimed to compare the primary stability of used self-drilling (SD) and self-tapping (ST) MIs with unused ones by performing the insertion torque measurement, Periotest and pull-out test. Materials and methods. Forty-six used (23 ST, 23 SD) and 46 unused (23 ST, 23 SD) MIs (1.5 mm x 8 mm) were inserted into a synthetic bone with the use of a digital screwdriver. Maximum insertion torque (MIT) values were recorded during the placement of MIs, and then Periotest measurements were made. Following the MIT and Periotest measurements, pull-out tests were performed on all MIs. Results. The median MIT values (Ncm) of the MIs were as follows: used ST: 17.3, unused ST: 18.9, used SD: 24.1, unused SD: 25.2. The median values obtained after the Periotest were (+/-): used ST: 0, unused ST: -1, used SD: -3, unused SD: -3. Median pull-out values (N) were: used ST: 148.12, unused ST: 168.12, used SD: 173.12, unused SD: 203.20. Statistically, MIT and pull- out values of the used ST and SD implants were significantly lower compared to those of the unused ST and SD implants (p < 0.05). Conclusions. Used orthodontic MIs showed poor performance compared with unused implants when they were inserted again in the in vitro conditions.
引用
收藏
页码:483 / 489
页数:7
相关论文
共 51 条
[41]   In vitro evaluation of insertion and removal torques of orthodontic mini-implants [J].
Pithon, M. M. ;
Nojima, M. G. ;
Nojima, L. I. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (01) :80-85
[42]   AN ARGUMENT FOR PACEMAKER REUSE - PACEMAKER MORTALITY IN 169 PATIENTS OVER 10 YEARS [J].
PRINGLE, RA ;
LEMAN, RB ;
KRATZ, JM ;
GILLETTE, PC .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1295-1298
[43]  
Ramp LC, 2000, INT J ORAL MAX IMPL, V15, P197
[44]   Re-use of implant coverscrews changes their surface properties but not clinical outcome [J].
Schwartz, Z ;
Lohmann, CH ;
Blau, G ;
Blanchard, CR ;
Soskolne, AW ;
Liu, YH ;
Cochran, DL ;
Dean, DD ;
Boyan, BD .
CLINICAL ORAL IMPLANTS RESEARCH, 2000, 11 (03) :183-194
[45]   Effects of screw and host factors on insertion torque and pullout strength [J].
Shah, Ankit H. ;
Behrents, Rolf G. ;
Kim, Ki Beom ;
Kyung, Hee-Moon ;
Buschang, Peter H. .
ANGLE ORTHODONTIST, 2012, 82 (04) :603-610
[46]   Comparative study of the primary stability of self-drilling and self-tapping orthodontic miniscrews [J].
Son, Seil ;
Motoyoshi, Mitsuru ;
Uchida, Yasuki ;
Shimizu, Noriyoshi .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (04) :480-485
[47]   Air abrasion of failed bonded metal brackets: A study of shear bond strength and surface characteristics as determined by scanning electron microscopy [J].
Sonis, AL .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 110 (01) :96-98
[48]   Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study [J].
Tepedino, Michele ;
Masedu, Francesco ;
Chimenti, Claudio .
HEAD & FACE MEDICINE, 2017, 13
[49]   Biomechanical and Histomorphometric Characterizations of Osseointegration during Mini-Screw Healing in Rabbit Tibiae [J].
Wu, Jing ;
Bai, Yu-Xing ;
Wang, Bang-Kang .
ANGLE ORTHODONTIST, 2009, 79 (03) :558-563
[50]   Comparison of the success rate between self-drilling and self-tapping miniscrews: a systematic review and meta-analysis [J].
Yi, Jianru ;
Ge, Mengke ;
Li, Meile ;
Li, Chunjie ;
Li, Yu ;
Li, Xiaobing ;
Zhao, Zhihe .
EUROPEAN JOURNAL OF ORTHODONTICS, 2017, 39 (03) :287-293