Characterization of a commercial bioluminescence tomography-guided system for pre-clinical radiation research

被引:3
作者
Xu, Xiangkun [1 ,6 ]
Deng, Zijian [1 ]
Sforza, Daniel [2 ]
Tong, Zhishen [1 ]
Tseng, Yu-Pei [1 ]
Newman, Ciara [1 ]
Reinhart, Merle [3 ]
Tsouchlos, Paul [3 ]
Devling, Tim [3 ]
Dehghani, Hamid [4 ]
Iordachita, Iulian [5 ]
Wong, John W. [2 ]
Wang, Ken Kang-Hsin [1 ,6 ]
机构
[1] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, Biomed Imaging & Radiat Technol Lab BIRTLab, Dallas, TX 75390 USA
[2] Johns Hopkins Univ, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD USA
[3] Xstrahl Inc, Suwanee, GA USA
[4] Univ Birmingham, Sch Comp Sci, Birmingham, England
[5] Johns Hopkins Univ, Lab Computat Sensing & Robot, Baltimore, MD USA
[6] Univ Texas Southwestern Med Ctr, Dept Radiat Oncol, 2201 Inwood Rd,Rm NC8 202, Dallas, TX 75390 USA
基金
美国国家卫生研究院;
关键词
bioluminescence tomography; image-guidance; pre-clinical research; radiation therapy; small animal irradiator; FLUORESCENCE MOLECULAR TOMOGRAPHY; X-RAY; RADIOTHERAPY; THERAPY; VISUALIZATION; IRRADIATION;
D O I
10.1002/mp.16669
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Widely used Cone-beam computed tomography (CBCT)-guided irradiators have limitations in localizing soft tissue targets growing in a low-contrast environment. This hinders small animal irradiators achieving precise focal irradiation.Purpose: To advance image-guidance for soft tissue targeting, we developed a commercial-grade bioluminescence tomography-guided system (BLT, MuriGlo) for pre-clinical radiation research. We characterized the system performance and demonstrated its capability in target localization. We expect this study can provide a comprehensive guideline for the community in utilizing the BLT system for radiation studies.Methods: MuriGlo consists of four mirrors, filters, lens, and charge-coupled device (CCD) camera, enabling a compact imaging platform and multi-projection and multi-spectral BLT. A newly developed mouse bed allows animals imaged in MuriGlo and transferred to a small animal radiation research platform (SARRP) for CBCT imaging and BLT-guided irradiation. Methods and tools were developed to evaluate the CCD response linearity, minimal detectable signal, focusing, spatial resolution, distortion, and uniformity. A transparent polycarbonate plate covering the middle of the mouse bed was used to support and image animals from underneath the bed. We investigated its effect on 2D Bioluminescence images and 3D BLT reconstruction accuracy, and studied its dosimetric impact along with the rest of mouse bed. A method based on pinhole camera model was developed to map multi-projection bioluminescence images to the object surface generated from CBCT image. The mapped bioluminescence images were used as the input data for the optical reconstruction. To account for free space light propagation from object surface to optical detector, a spectral derivative (SD) method was implemented for BLT reconstruction. We assessed the use of the SD data (ratio imaging of adjacent wavelength) in mitigating out of focusing and non-uniformity seen in the images. A mouse phantom was used to validate the data mapping. The phantom and an in vivo glioblastoma model were utilized to demonstrate the accuracy of the BLT target localization.Results: The CCD response shows good linearity with < 0.6% residual from a linear fit. The minimal detectable level is 972 counts for 10 x 10 binning. The focal plane position is within the range of 13-18 mm above the mouse bed. The spatial resolution of 2D optical imaging is < 0.3 mm at Rayleigh criterion. Within the region of interest, the image uniformity is within 5% variation, and image shift due to distortion is within 0.3 mm. The transparent plate caused < 6% light attenuation. The use of the SD imaging data can effectively mitigate out of focusing, image non-uniformity, and the plate attenuation, to support accurate multi-spectral BLT reconstruction. There is < 0.5% attenuation on dose delivery caused by the bed. The accuracy of data mapping from the 2D bioluminescence images to CBCT image is within 0.7 mm. Our phantom test shows the BLT system can localize a bioluminescent target within 1 mm with an optimal threshold and only 0.2 mm deviation was observed for the case with and without a transparent plate. The same localization accuracy can be maintained for the in vivo GBM model.Conclusions: This work is the first systematic study in characterizing the commercial BLT-guided system. The information and methods developed will be useful for the community to utilize the imaging system for image-guided radiation research.
引用
收藏
页码:6433 / 6453
页数:21
相关论文
共 38 条
[1]  
[Anonymous], AM HTX IM SYST SPECT
[2]  
[Anonymous], IVIS SPECTR IN VIV I
[3]   Quantitative molecular bioluminescence tomography [J].
Bentley, Alexander ;
Xu, Xiangkun ;
Deng, Zijian ;
Rowe, Jonathan E. ;
Kang-Hsin Wang, Ken ;
Dehghani, Hamid .
JOURNAL OF BIOMEDICAL OPTICS, 2022, 27 (06)
[4]   A scoping review of small animal image-guided radiotherapy research: Advances, impact and future opportunities in translational radiobiology [J].
Brown, Kathryn H. ;
Ghita, Mihaela ;
Dubois, Ludwig J. ;
de Ruysscher, Dirk ;
Prise, Kevin M. ;
Verhaegen, Frank ;
Butterworth, Karl T. .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2022, 34 :112-119
[5]   Geometrical co-calibration of a tomographic optical system with CT for intrinsically co-registered imaging [J].
Cao, Liji ;
Breithaupt, Mathies ;
Peter, Joerg .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06) :1591-1606
[6]   Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging [J].
Chaudhari, AJ ;
Darvas, F ;
Bading, JR ;
Moats, RA ;
Conti, PS ;
Smith, DJ ;
Cherry, SR ;
Leahy, RM .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23) :5421-5441
[7]   Validation of GPU-accelerated superposition-convolution dose computations for the Small Animal Radiation Research Platform [J].
Cho, Nathan ;
Tsiamas, Panagiotis ;
Velarde, Esteban ;
Tryggestad, Erik ;
Jacques, Robert ;
Berbeco, Ross ;
McNutt, Todd ;
Kazanzides, Peter ;
Wong, John .
MEDICAL PHYSICS, 2018, 45 (05) :2252-2265
[8]   Characterization of image quality and image-guidance performance of a preclinical microirradiator [J].
Clarkson, R. ;
Lindsay, P. E. ;
Ansell, S. ;
Wilson, G. ;
Jelveh, S. ;
Hill, R. P. ;
Jaffray, D. A. .
MEDICAL PHYSICS, 2011, 38 (02) :845-856
[9]   Of Mice and Humans: Are They the Same?-Implications in Cancer Translational Research [J].
de Jong, Marion ;
Maina, Theodosia .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (04) :501-504
[10]   Spectrally resolved bioluminescence optical tomography [J].
Dehghani, H ;
Davis, SC ;
Jiang, SD ;
Pogue, BW ;
Paulsen, KD ;
Patterson, MS .
OPTICS LETTERS, 2006, 31 (03) :365-367