Ultra-short T2 components imaging of the whole brain using 3D dual-echo UTE MRI with rosette k-space pattern

被引:14
|
作者
Shen, Xin [1 ]
Ozen, Ali Caglar [2 ]
Sunjar, Antonia [1 ]
Ilbey, Serhat [2 ]
Sawiak, Stephen [3 ,4 ]
Shi, Riyi [1 ,5 ]
Chiew, Mark [6 ]
Emir, Uzay [1 ,7 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Univ Freiburg, Med Ctr, Fac Med, Dept Radiol Med Phys, Freiburg, Germany
[3] Univ Cambridge, Dept Clin Neurosci, Cambridge, England
[4] Univ Cambridge, Dept Psychol, Cambridge, England
[5] Purdue Univ, Coll Vet Med, W Lafayette, IN 47907 USA
[6] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Oxford, England
[7] Purdue Univ, Sch Hlth Sci, 550 Stadium Mall Dr, W Lafayette, IN 47907 USA
关键词
k-space; microstructure; non-Cartesian; rosette trajectory; ultra-short echo time; MYELIN WATER FRACTION; IRON DEPOSITION; MAGNETIC-FIELD; TIME MRI; ROBUST; QUANTIFICATION; RECONSTRUCTION; OPTIMIZATION; REGISTRATION; RELAXATION;
D O I
10.1002/mrm.29451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study aimed to develop a new 3D dual-echo rosette k-space trajectory, specifically designed for UTE MRI applications. The imaging of the ultra-short transverse relaxation time (uT(2)) of brain was acquired to test the performance of the proposed UTE sequence. Theory and Methods The rosette trajectory was developed based on rotations of a "petal-like" pattern in the k(x)-k(y) plane, with oscillated extensions in the k(z)-direction for 3D coverage. Five healthy volunteers underwent 10 dual-echo 3D rosette UTE scans with various TEs. Dual-exponential complex model fitting was performed on the magnitude data to separate uT(2) signals, with the output of uT(2) fraction, uT(2) value, and long-T-2 value. Results The 3D rosette dual-echo UTE sequence showed better performance than a 3D radial UTE acquisition. More significant signal intensity decay in white matter than gray matter was observed along with the TEs. The white matter regions had higher uT(2) fraction values than gray matter (10.9% +/- 1.9% vs. 5.7% +/- 2.4%). The uT(2) value was approximately 0.10 ms in white matter . Conclusion The higher uT(2) fraction value in white matter compared to gray matter demonstrated the ability of the proposed sequence to capture rapidly decaying signals.
引用
收藏
页码:508 / 521
页数:14
相关论文
共 50 条
  • [1] Development of 3D Rosette K-Space Trajectory in Ultra-Short Echo Time MRI Applications
    Shen, X.
    Chiew, M.
    Emir, U.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [2] High-resolution 3D ultra-short echo time MRI with Rosette k-space pattern for brain iron content mapping
    Shen, Xin
    Oezen, Ali Caglar
    Monsivais, Humberto
    Susnjar, Antonia
    Ilbey, Serhat
    Zheng, Wei
    Du, Yansheng
    Chiew, Mark
    Emir, Uzay
    JOURNAL OF TRACE ELEMENTS IN MEDICINE AND BIOLOGY, 2023, 77
  • [3] Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI
    Neville D. Gai
    Ashkan A. Malayeri
    David A. Bluemke
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 387 - 395
  • [4] Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI
    Gai, Neville D.
    Malayeri, Ashkan A.
    Bluemke, David A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (04) : 387 - 395
  • [5] Quantifying Auricular Cartilage in Vivo Using Ultra-Short Echo Time (UTE) T2*Mapping
    Li, Xue
    Li, Enhui
    Zhang, Weiwei
    THIRD INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE (ISICDM 2019), 2019, : 138 - 142
  • [6] Correcting T2 Maps Calculated From Dual-Echo Fast Spin Echo MRI for the Effects of K-Space Profile Order and Stimulated Echoes
    Gabr, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E109 - E109
  • [7] MRI Characterization of 3D Printed Anatomic Models Using a Dual-Echo Ultrashort TE (UTE) Sequence
    Wake, N.
    Peng, Q.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Segmentation and visualization of the human cranial bone by T2*approximation using ultra-short echo time (UTE) magnetic resonance imaging
    Kraemer, Martin
    Herzau, Benedikt
    Reichenbach, Juergen R.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (01): : 51 - 59
  • [9] Kidney Stone Imaging with 3D Ultra-Short Echo Time (UTE) Magnetic Resonance Imaging. A Phantom Study
    Ibrahim, El-Sayed H.
    Pooley, Robert A.
    Bridges, Mellena D.
    Cernigliaro, Joseph G.
    Haley, William E.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2356 - 2359
  • [10] A black-blood ultra-short echo time (UTE) sequence for 3D isotropic resolution imaging of the lungs
    Delacoste, Jean
    Feliciano, Helene
    Yerly, Jerome
    Dunet, Vincent
    Beigelman-Aubry, Catherine
    Ginami, Giulia
    van Heeswijk, Ruud B.
    Piccini, Davide
    Stuber, Matthias
    Sauty, Alain
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3808 - 3818