Hybridization chain reaction assisted multicolor immunosensor for sensitively detection of human chorionic gonadotropin

被引:2
|
作者
Ma, Feifei [1 ]
Zhao, Zhe [2 ]
Huang, Jiahui [2 ]
Xiong, Qing [2 ]
Xu, Shaohua [2 ]
Lin, Zhenyu [3 ]
机构
[1] Hangzhou Normal Univ, Affiliated Xiaoshan Hosp, Dept Gynecol, Hangzhou 311200, Peoples R China
[2] Jiangxi Univ Chinese Med, Integrated Chinese & Western Med Canc Res Ctr, Nanchang 330004, Jiangxi, Peoples R China
[3] Fuzhou Univ, Coll Chem, Fujian Prov Key Lab Anal & Detect Food Safety, Minist Educ,Key Lab Analyt Sci Food Safety & Biol, Fuzhou 350116, Fujian, Peoples R China
基金
中国国家自然科学基金;
关键词
Human chorionic gonadotropin; Multicolor immunosensor; Gold nanobipyramids; Localized surface plasmon resonance; Naked eye detection; GOLD NANOPARTICLES; ADENOCARCINOMA; AMPLIFICATION; IMMUNOASSAY; OXIDATION; NANORODS; GROWTH; YIELD; ASSAY; HCG;
D O I
10.1016/j.talanta.2023.125578
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The level of human chorionic gonadotropin (HCG) is an important indicator for early pregnancy, pregnancy-related diseases trophoblastic diseases and even cancer diagnosis. Therefore, sensitive detection of HCG has crucial significance in clinical, especially in gynaecology and obstetrics. Herein, a hybridization chain reaction (HCR) assisted multicolor immunosensor have been developed for HCG analysis. The proposed method intro-duced HCR after the immunoreaction between antibody and HCG protein, and produced long double strand DNA (dsDNA) that contain biotin sites. The streptavidin-horseradish peroxidase was linked on the dsDNA by the interaction between biotin and streptavidin, and can further mediated gold nanobipyramids (Au NBPs) etching. The localized surface plasmon resonance absorption peaks of Au NBPs blue shift and accompanied a vivid color change after etching effect. Based on this color change, HCG could be qualitative and semi-quantitative detected. Because of the introduction of HCR and enzyme amplification technique, the proposed method exhibited high sensitivity with a linear range of 0.1-2000 pg/mL and limit of detection (LOD) of 0.1 pg/mL. Finally, the pro-posed immunosensor was used to detect clinical serum samples. The results show there are no significant dif-ferences between clinical results and the test results by this method, indicating the practicability of the proposed method.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Supramolecular Amperometric Immunosensor for Detection of Human Chorionic Gonadotropin
    Ortiz, Mayreli
    Wilson, Lindsay
    Botero, Mary L.
    Baker, Priscilla
    Iwuoha, Emmanuel
    Fragoso, Alex
    O'Sullivan, Ciara K.
    ELECTROANALYSIS, 2014, 26 (07) : 1481 - 1487
  • [2] Photoanode-supported cathodic immunosensor for sensitive and specific detection of human chorionic gonadotropin
    Lu, Yibin
    Wang, Hao
    Shi, Xiao-Mei
    Ding, Caifeng
    Fan, Gao-Chao
    ANALYTICA CHIMICA ACTA, 2022, 1199
  • [3] Epitaxial graphene immunosensor for human chorionic gonadotropin
    Teixeira, Sofia
    Burwell, G.
    Castaing, A.
    Gonzalez, D.
    Conlan, R. S.
    Guy, O. J.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 190 : 723 - 729
  • [4] An Electrochemical Immunosensor Based on Gold Nanoparticles Decorated Cobalt Boride Nanosheet Arrays for Detection of Human Chorionic Gonadotropin
    Lu Wen-Bo
    Bao Can-Can
    Wei Ming
    Niu Qiang-Qiang
    Bai Li-Wei
    Cao Xiao-Wei
    Jia Jian-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 49 (12) : 2075 - 2085
  • [5] A sensitive electrochemical immunosensor for the detection of human chorionic gonadotropin based on a hierarchical nanoporous AuAg alloy
    Zhao, Dianyun
    Yu, Yang
    Xu, Caixia
    RSC ADVANCES, 2016, 6 (01): : 87 - 93
  • [6] Advances in human chorionic gonadotropin detection technologies: a review
    Fan, Jing
    Wang, Mandy
    Wang, Chengyin
    Cao, Yu
    BIOANALYSIS, 2017, 9 (19) : 1509 - 1529
  • [7] Electrochemical Immunosensor for Ultrasensitive Detection of Human Chorionic Gonadotropin Based on Pd@SBA-15
    Wu, Dan
    Zhang, Yong
    Shi, Li
    Cai, Yanyan
    Ma, Hongmin
    Du, Bin
    Wei, Qin
    ELECTROANALYSIS, 2013, 25 (02) : 427 - 432
  • [8] Sensitive sandwich electrochemical immunosensor for human chorionic gonadotropin using nanoporous Pd as a label
    Liu, Yiming
    Guo, Wenjuan
    Qin, Xiaoli
    Meng, Xue
    Zhu, Xiangwei
    Wang, Jinping
    Pei, Meishan
    Wang, Luyan
    RSC ADVANCES, 2014, 4 (42) : 21891 - 21898
  • [9] AN ASSAY FOR HUMAN CHORIONIC-GONADOTROPIN USING THE CAPILLARY FILL IMMUNOSENSOR
    DEACON, JK
    THOMSON, AM
    PAGE, AL
    STOPS, JE
    ROBERTS, PR
    WHITELEY, SC
    ATTRIDGE, JW
    LOVE, CA
    ROBINSON, GA
    DAVIDSON, GP
    BIOSENSORS & BIOELECTRONICS, 1991, 6 (03) : 193 - 199
  • [10] Development of molecularly imprinted polymers for the detection of human chorionic gonadotropin
    Zubryte, Radvile
    Mavliutova, Liliia
    Garcia, Yadiris
    Sullivan, Mark V.
    Turner, Nicholas W.
    Patitucci, Francesco
    Polania, Laura C.
    Jimenez, Veronica A.
    Porter, Robert
    Mattsson, Alice
    Sellergren, Borje
    SCIENTIFIC REPORTS, 2025, 15 (01):