Diboronic-Acid-Based Electrochemical Sensor for Enzyme-Free Selective and Sensitive Glucose Detection

被引:7
作者
Kim, Joong-Hyun [1 ]
Choi, Hongsik [1 ]
Park, Chul-Soon [1 ]
Yim, Heung-Seop [1 ]
Kim, Dongguk [2 ,3 ]
Lee, Sungmin [1 ]
Lee, Yeonkeong [1 ]
机构
[1] Daegu Gyeongbuk Med Innovat Fdn, Drug Mfg Ctr, 80 Chumbok Ro, Daegu 41061, South Korea
[2] Daegu Gyeongbuk Med Innovat Fdn, Med Device Dev Ctr, 80 Chumbok Ro, Daegu 41061, South Korea
[3] Chungbuk Natl Univ, Dept Biomed Engn, 1 Chungdae Ro, Cheongju 28644, South Korea
来源
BIOSENSORS-BASEL | 2023年 / 13卷 / 02期
基金
新加坡国家研究基金会;
关键词
diabetes; glucose monitoring; boronic acid; electrochemical sensor; self-assembly; BORONIC ACID;
D O I
10.3390/bios13020248
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A diboronic acid anthracene-based fluorescent system for detecting blood glucose could be used for 180 days. However, there has not yet been a boronic acid immobilized electrode to selectively detect glucose in a signal-increased way. Considering malfunctions of sensors at high sugar levels, the electrochemical signal should be increased proportionally to the glucose concentration. Therefore, we synthesized a new diboronic acid derivative and fabricated the derivative-immobilized electrodes for the selective detection of glucose. We performed cyclic voltammetry and electrochemical impedance spectroscopy with an Fe(CN)(6)(3-/4-) redox pair for detecting glucose in the range of 0-500 mg/dL. The analysis revealed increased electron-transfer kinetics such as increased peak current and decreased semicircle radius of Nyquist plots as the glucose concentration increased. The cyclic voltammetry and impedance spectroscopy showed that the linear detection range of glucose was 40 to 500 mg/dL with limits of detection of 31.2 mg/dL and 21.5 mg/dL, respectively. We applied the fabricated electrode to detect glucose in artificial sweat and obtained 90% of the performance of the electrodes in PBS. Cyclic voltammetry measurements of other sugars such as galactose, fructose, and mannitol also showed linear increased peak currents proportional to the concentrations of the tested sugars. However, the slopes of the sugars were lower than that of glucose, indicating selectivity for glucose. These results proved the newly synthesized diboronic acid is a promising synthetic receptor for developing a long-term usable electrochemical sensor system.
引用
收藏
页数:14
相关论文
共 35 条
[1]   A Review of Non-Invasive Optical Systems for Continuous Blood Glucose Monitoring [J].
Alsunaidi, Bushra ;
Althobaiti, Murad ;
Tamal, Mahbubunnabi ;
Albaker, Waleed ;
Al-Naib, Ibraheem .
SENSORS, 2021, 21 (20)
[2]  
[Anonymous], 2018, Idf diabetes atlas, Veighth
[3]   Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study [J].
Bandodkar, Amay J. ;
Jia, Wenzhao ;
Yardimci, Ceren ;
Wang, Xuan ;
Ramirez, Julian ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :394-398
[4]   Electrocatalysts for Glucose Electrooxidation Reaction: A Review [J].
Brouzgou, A. ;
Tsiakaras, P. .
TOPICS IN CATALYSIS, 2015, 58 (18-20) :1311-1327
[5]   The robust electrochemical detection of a Parkinson's disease marker in whole blood sera [J].
Bryan, Thomas ;
Luo, Xiliang ;
Forsgren, Lars ;
Morozova-Roche, Ludmilla A. ;
Davis, Jason J. .
CHEMICAL SCIENCE, 2012, 3 (12) :3468-3473
[6]   Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3 [J].
Canbaz, Mehmet Cetin ;
Simsek, Cigdem Sayikli ;
Sezginturk, Mustafa Kemal .
ANALYTICA CHIMICA ACTA, 2014, 814 :31-38
[7]   Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications [J].
Cappon, Giacomo ;
Vettoretti, Martina ;
Sparacino, Giovanni ;
Facchinetti, Andrea .
DIABETES & METABOLISM JOURNAL, 2019, 43 (04) :383-397
[8]   An enzyme-free glucose sensor based on a difunctional diboronic acid for molecular recognition and potentiometric transduction [J].
Chen, Hongduo ;
Li, Long ;
Guo, Huimin ;
Wang, Xuewei ;
Qin, Wei .
RSC ADVANCES, 2015, 5 (18) :13805-13808
[9]   Acetylated Trifluoromethyl Diboronic Acid Anthracene with a Large Stokes Shift and Long Excitation Wavelength as a Glucose-Selective Probe [J].
Choi, Hongsik ;
Song, Inhyeok ;
Park, Chul Soon ;
Yim, Heung-seop ;
Kim, Joong Hyun .
APPLIED SCIENCES-BASEL, 2022, 12 (06)
[10]  
Colvin A., 2010, U.S. Patent, Patent No. [7,851,225, 7851225]