Biomechanical influence of narrow-diameter implants placed at the crestal and subcrestal level in the maxillary anterior region. A 3D finite element analysis

被引:2
作者
Cruz, Ronaldo S. [1 ]
Fernandes e Oliveira, Hiskell Francine [1 ]
Lemos, Cleidiel Aparecido Araujo [2 ]
Batista, Victor Eduardo de Souza [3 ]
da Silva, Rodrigo Capalbo [1 ]
Verri, Fellippo R. [1 ]
机构
[1] Univ Estadual Paulista, Aracatuba Dent Sch UNESP, Dept Dent Mat & Prosthodont, Jose Bonifacio St 1193, BR-16015050 Aracatuba, SP, Brazil
[2] Fed Univ Juiz de Fora UFJF, Dept Dent, Div Prosthodont, Campus Governador Valadares, Governador Valadares, MG, Brazil
[3] Univ Western Sao Paulo UNOESTE, Presidente Prudente Dent Sch, Dept Prosthodont, Presidente Prudente, Brazil
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2024年 / 33卷 / 02期
基金
巴西圣保罗研究基金会;
关键词
dental implants; dental prosthesis; finite element analysis; DENTAL IMPLANTS; STRESS-DISTRIBUTION; EXTERNAL HEXAGON; BONE-RESORPTION; LENGTH; SURFACE; CROWN; CONNECTION; SURVIVAL; TISSUE;
D O I
10.1111/jopr.13667
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeTo evaluate the tendency of movement, stress distribution, and microstrain of single-unit crowns in simulated cortical and trabecular bone, implants, and prosthetic components of narrow-diameter implants with different lengths placed at the crestal and subcrestal levels in the maxillary anterior region using 3D finite element analysis (FEA). Materials and methodsSix 3D models were simulated using Invesalius 3.0, Rhinoceros 4.0, and SolidWorks software. Each model simulated the right anterior maxillary region including a Morse taper implant of o2.9 mm with different lengths (7, 10, and 13 mm) placed at the crestal and subcrestal level and supporting a cement-retained monolithic single crown in the area of tooth 12. The FEA was performed using ANSYS 19.2. The simulated applied force was 178 N at 0 degrees, 30 degrees, and 60 degrees. The results were analyzed using maps of displacement, von Mises (vM) stress, maximum principal stress, and microstrain. ResultsModels with implants at the subcrestal level showed greater displacement. vM stress increased in the implant and prosthetic components when implants were placed at the subcrestal level compared with the crestal level; the length of the implants had a low influence on the stress distribution. Higher stress and strain concentrations were observed in the cortical bone of the subcrestal placement, independent of implant length. Non-axial loading influenced the increased stress and strain in all the evaluated structures. ConclusionsNarrow-diameter implants positioned at the crestal level showed a more favorable biomechanical behavior for simulated cortical bone, implants, and prosthetic components. Implant length had a smaller influence on stress or strain distribution than the other variables.
引用
收藏
页码:180 / 187
页数:8
相关论文
共 47 条
[41]   Nasal Floor Elevation for Implant Treatment in the Atrophic Premaxilla: A Within-Patient Comparative Study [J].
Torres Garcia-Denche, Jesus ;
Abbushi, Abdullah ;
Hernandez, Gonzalo ;
Fernandez-Tresguerres, Isabel ;
Lopez-Cabarcos, Enrique ;
Tamimi, Faleh .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 :E520-E530
[42]   Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types [J].
Verri, Fellippo Ramos ;
Santiago, Joel Ferreira, Jr. ;
Faria Almeida, Daniel Augusto ;
de Souza Batista, Victor Eduardo ;
Araujo Lemos, Cleidiel Aparecido ;
Mello, Caroline Cantieri ;
Pellizzer, Eduardo Piza .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) :E191-E198
[43]   Can the modeling for simplification of a dental implant surface affect the accuracy of 3D finite element analysis? [J].
Verri, Fellippo Ramos ;
Cruz, Ronaldo Silva ;
de Souza Batista, Victor Eduardo ;
de Faria Almeida, Daniel Augusto ;
Goncales Verri, Ana Caroline ;
de Araujo Lemos, Cleidiel Aparecido ;
Santiago Junior, Joel Ferreira ;
Pellizzer, Eduardo Piza .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (15) :1665-1672
[44]  
Verri Fellippo Ramos, 2015, ScientificWorldJournal, V2015, P321528, DOI 10.1155/2015/321528
[45]   Biomechanical influence of crown-to-implant ratio on stress distribution over internal hexagon short implant: 3-D finite element analysis with statistical test [J].
Verri, Fellippo Ramos ;
Santiago Junior, Joel Ferreira ;
de Faria Almeida, Daniel Augusto ;
Brandao de Oliveira, Guilherme Bergamo ;
de Souza Batista, Victor Eduardo ;
Honorio, Heitor Marques ;
Noritomi, Pedro Yoshito ;
Pellizzer, Eduardo Piza .
JOURNAL OF BIOMECHANICS, 2015, 48 (01) :138-145
[46]   Effect of crown-to-implant ratio on peri-implant stress: A finite element analysis [J].
Verri, Fellippo Ramos ;
de Souza Batista, Victor Eduardo ;
Santiago, Joel Ferreira, Jr. ;
de Faria Almeida, Daniel Augusto ;
Pellizzer, Eduardo Piza .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 45 :234-240
[47]   Comparison of Crestal Bone Loss Around Dental Implants Placed in Healed Sites Using Flapped and Flapless Techniques: A Systematic Review [J].
Vohra, Fahim ;
Al-Kheraif, Abdulaziz A. ;
Almas, Khalid ;
Javed, Fawad .
JOURNAL OF PERIODONTOLOGY, 2015, 86 (02) :185-191