Buttock Augmentation with Ultrasonic Liposuction and Ultrasound-Guided Fat Grafting: A Retrospective Analysis Based on 185 Patients

被引:1
|
作者
Elsaftawy, Ahmed [1 ]
Ostrowski, Patryk [2 ,3 ]
Bonczar, Michal [2 ,3 ]
Stolarski, Mateusz [1 ]
Gabryszuk, Kamil [1 ]
Bonczar, Tomasz [1 ]
机构
[1] Chiroplast Lower Silesian Ctr Hand & Aesthet Surg, PL-54117 Wroclaw, Poland
[2] Jagiellonian Univ Med Coll Cracow, Dept Anat, PL-33332 Krakow, Poland
[3] Youth Res Org, Youthoria, PL-30363 Krakow, Poland
关键词
buttock augmentation; liposuction; fat grafting; plastic surgery; aesthetic surgery; GLUTEAL AUGMENTATION; EXPERIENCE;
D O I
10.3390/jcm13061526
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The popularity of gluteal augmentation has surged in recent decades, primarily due to satisfactory aesthetic results. Objectives: The primary goal of this retrospective analysis was to present the key characteristics of a large patient cohort from Europe, comprising 185 female patients who underwent gluteal augmentation with ultrasound-guided fat grafting. Methods: A retrospective analysis was conducted on 185 female patients who underwent gluteal augmentation with ultrasonic liposuction and fat grafting from February 2020 to July 2023. The procedures were performed in accordance with the latest safety recommendations. Results: Information concerning the patient demographic, volume of fat graft, and complications was analyzed. Additionally, patient satisfaction was evaluated through a questionnaire. The mean Body Mass Index (BMI) of the patients was 23.00 kg/m2 (SD = 2.62). Furthermore, the volume of transferred fat graft ranged from 500.00 mL to 800.00 mL, with a mean of 596.75 mL (SD = 67.29). The most frequent complication was the formation of seroma (5.41%). All complications were treated successfully. Conclusions: Using ultrasonic liposuction and ultrasound-guided fat grafting to enhance buttock contours is a reliable technique. Nevertheless, it is crucial to exert caution and take all necessary steps to reduce the risk of potentially life-threatening complications.
引用
收藏
页数:13
相关论文
共 11 条
  • [1] Enhancing Buttock Contours: A Safer Approach to Gluteal Augmentation with Ultrasonic Liposuction, Submuscular Implants, and Ultrasound-Guided Fat Grafting
    Elsaftawy, Ahmed
    Ostrowski, Patryk
    Bonczar, Michal
    Stolarski, Mateusz
    Gabryszuk, Kamil
    Bonczar, Tomasz
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)
  • [2] Ultrasound-Guided Gluteal Fat Grafting: A to Z
    Pazmino, Pat
    CLINICS IN PLASTIC SURGERY, 2023, 50 (04) : 587 - 601
  • [3] Staged ultrasound-guided liposuction for hidden arteriovenous fistulas in obese patients
    Nagy, Gabor Cs
    Verwiebe, Reiner
    Wunsch, Matthias
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2018, 47 (05) : 403 - 407
  • [4] Augmented Safety Profile of Ultrasound-Guided Gluteal Fat Transfer: Retrospective Study With 1815 Patients
    Vidal-Laureano, Natalia
    Huerta, Carlos T.
    Perez, Eduardo A.
    Earle, Steven Alexander
    AESTHETIC SURGERY JOURNAL, 2024, 44 (04) : NP263 - NP270
  • [5] RETROSPECTIVE ANALYSIS OF ULTRASOUND-DETECTED BLEEDING COMPLICATIONS AFTER ULTRASOUND-GUIDED TRANSCUTANEOUS KIDNEY BIOPSIES
    Preuss, Stephanie
    Kuechle, Claudius
    Wagenpfeil, Stefan
    Schmaderer, Christoph
    Renders, Lutz
    Heemann, Uwe
    Stock, Konrad
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (01) : 153 - 162
  • [6] Autologous fat grafting and breast cancer recurrences: Retrospective analysis of a series of 100 procedures in 64 patients
    Ihrai, Tarik
    Georgiou, Charalambos
    Machiavello, Jean-Christophe
    Chignon-Sicard, Berengere
    Figl, Andrea
    Raoust, Ines
    Bourgeon, Yveline
    Fouche, Yves
    Flipo, Bernard
    JOURNAL OF PLASTIC SURGERY AND HAND SURGERY, 2013, 47 (04) : 273 - 275
  • [7] Ultrasound-Guided Radiological Placement of Central Venous Port via the Subclavian Vein: A Retrospective Analysis of 500 Cases at a Single Institute
    Sakamoto, Noriaki
    Arai, Yasuaki
    Takeuchi, Yoshito
    Takahashi, Masahide
    Tsurusaki, Masakatsu
    Sugimura, Kazuro
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (05) : 989 - 994
  • [8] Safety and efficacy of endoscopic ultrasound-guided gastroenterostomy using double balloon occlusion methods: a clinical retrospective study in 36 patients with malignant gastric outlet obstruction
    Xu, Guifang
    Shen, Yonghua
    Lv, Ying
    Zhou, Xiaoliang
    Li, Wen
    Wang, Yi
    Hassan, Shahzeb
    Wang, Lei
    Zou, Xiaoping
    ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (11) : E1690 - E1697
  • [9] The effectiveness of ultrasound-guided core needle biopsy in detecting lymph node metastases in the axilla in patients with breast cancer: systematic review and meta-analysis
    Xu, Qi
    Wang, Jiale
    Wang, Jing
    Guo, Runzhao
    Qian, Yao
    Liu, Feng
    CLINICS, 2023, 78
  • [10] Complications After Percutaneous Ultrasound-Guided Liver Biopsy A Systematic Review and Meta-analysis of a Population of More Than 12,000 Patients From 51 Cohort Studies
    Tian, Guo
    Kong, Dexing
    Jiang, Tian'an
    Li, Lanjuan
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (07) : 1355 - 1365