Experimental Study on Wooden Pin Reinforcement of the Typical Mortise-Tenon Joints of Ancient Timber Frames

被引:1
|
作者
Ren, Quanchang [1 ,2 ,3 ]
Liang, Bin [4 ]
Zhou, Yan [1 ]
Liu, Ge [1 ]
Yang, Yanan [1 ]
Lu, Liqiang [1 ,2 ]
机构
[1] Tianjin Chengjian Univ, Sch Civil Engn, Tianjin, Peoples R China
[2] Tianjin Key Lab Civil Bldg Protect & Reinforcement, Tianjin, Peoples R China
[3] Tianjin Chengjian Univ, Key Lab Soft Soil Engn Character & Engn Environm T, Tianjin, Peoples R China
[4] Dalian Univ Technol, Dept Civil Engn, Dalian 116024, Peoples R China
关键词
Ancient timber frames; finite element analysis; mortise-tenon joints; quasi-static test; reinforcement; BEHAVIOR; EARTHQUAKE;
D O I
10.1080/15583058.2024.2320408
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The ancient timber frames is the precious architectural heritage of China. The seismic performance of mortise tenon joints (MTJ) directly affects the seismic performance of the ancient timber frames. This study presents a method that utilizes wooden pins to reinforce MTJs, enhancing the seismic performance of timber frame structures. The quasi-static test and finite element model were carried out to study the mechanical properties of the MTJ reinforced by the wood pins. From the failure state of the MTJs, it is found that the main deformation is the slip deformation between mortise and tenon. The mutual friction between the mortise and the tenon has a certain energy dissipation and shock absorption effect. The deformation state, stress distribution, stiffness degradation curve, etc. of the MTJ were obtained by finite element model of the MTJ. Additionally, the study confirms that reinforced MTJ can help restrict displacement changes within the wooden frame. The results show the bearing capacity of MJT reinforced with wooden pins is approximately 11.3% higher compared to that of MTJ without reinforcement. The reinforcement of wood pins effectively controls the horizontal displacement of the wooden frame, which is reduced by about 50%-62% compared with the unreinforced wooden frame. The locating the wooden pin-reinforced MTJs in the outer columns and middle layer columns reduces structural displacement, which is 31.53% in X derection, 5% in Y derection, 25.86% in Z derection.
引用
收藏
页数:23
相关论文
共 34 条
  • [1] Experimental Study on the Traditional Timber Mortise-Tenon Joints
    Li, Xiaowei
    Zhao, Junhai
    Ma, Guowei
    Huang, Shuanghua
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (12) : 2089 - 2102
  • [2] Experimental Study on the Seismic Behaviour of Mortise-Tenon Joints of the Ancient Timbers
    Chen, Ling-kun
    Li, Sheng-cai
    Wang, Yan-ting
    Zhao, You-jun
    Zhang, Ming
    Song, Xing-yu
    Li, Xiao-wei
    Wu, Teng
    Jiang, Li-zhong
    STRUCTURAL ENGINEERING INTERNATIONAL, 2017, 27 (04) : 512 - 519
  • [3] Experimental study on fire resistance of traditional timber mortise-tenon joints with damages
    Song, Xiao-bin
    Zhang, Yu
    Lu, Yu
    Peng, Yi-qing
    Zhou, Haizhu
    FIRE SAFETY JOURNAL, 2023, 138
  • [4] Experimental study and theoretical analysis on mechanical properties of mortise-tenon joints in composite frames
    Jin B.
    Luo B.
    Shu X.
    He R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (02): : 173 - 183
  • [5] EXPERIMENTAL STUDY ON SEISMIC BEHAVIOR OF MORTISE-TENON JOINTS REINFORCED WITH CFRP SHEETS AND FLAT STEEL IN CHINESE ANCIENT WOODEN BUILDING
    Xue, Jian-Yang
    Yu, Ye-Shuan
    Zhao, Hong-Tie
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 581 - 586
  • [6] Experimental and numerical study of mortise-tenon joints reinforced with innovative friction damper
    Xue, Jianyang
    Wu, Chenwei
    Zhang, Xicheng
    Qi, Zhendong
    ENGINEERING STRUCTURES, 2021, 230
  • [7] Experimental and numerical studies on fire resistance of damaged traditional mortise-tenon jointed timber frames
    Lu, Yu
    Song, Xiaobin
    Peng, Yiqing
    Zhang, Baozhuang
    Chen, Yunxiao
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [8] Study on flexural behavior of straight mortise-tenon joints
    Chen C.
    Qiu H.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 : 292 - 298
  • [9] Experimental study on seismic behavior of mortise-tenon joints reinforced with shape memory alloy
    Xue, Jianyang
    Wu, Chenwei
    Zhang, Xicheng
    Zhang, Yutao
    ENGINEERING STRUCTURES, 2020, 218
  • [10] EXPLORING RULE-BASED DISCRETE TIMBER DESIGN WITH MORTISE-TENON JOINTS
    Xu, Qianbin
    Teixeira, Frederico Fialho
    Shafiei, Maryam
    PROCEEDINGS OF THE 29TH INTERNATIONAL CONFERENCE OF THE ASSOCIATION FOR COMPUTER-AIDED ARCHITECTURAL DESIGN RESEARCH IN ASIA, CAADRIA 2024, VOL 1, 2024, : 313 - 322