Effect of aging on color, gloss and surface roughness of CAD/CAM composite materials

被引:18
作者
Papathanasiou, Ioannis [1 ]
Zinelis, Spiros [2 ]
Papavasiliou, George [3 ]
Kamposiora, Phophi [3 ]
机构
[1] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, 2 Thivon Str, Athens 11527, Greece
[2] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Biomat, Athens, Greece
[3] Natl & Kapodistrian Univ Athens, Sch Dent, Dept Prosthodont, Athens, Greece
关键词
CAD; CAM; composite resins; color stability; gloss; surface roughness; aging; RESIN COMPOSITES; STAINABILITY; BLOCKS; SUSCEPTIBILITY; DETERIORATION;
D O I
10.1016/j.jdent.2023.104423
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess the effect of aging procedures on color, gloss and surface roughness of CAD/CAM composite materials. Methods: 6 CAD/CAM composite materials (Brilliant CRIOS, Cerasmart, Lava Ultimate, Tetric CAD, Shofu Block HC, Grandio Blocs) were tested. 10 CAD/CAM fabricated specimens of each material polished according to manufacturers' recommendations, were subjected to one of the following aging procedures; immersion in coffee (30 days, 37 omicron C), water thermocycling (5000 cycles, 5-55 degrees C) and photoaging (150,000 kJ/m2). Color, gloss and surface roughness measurements were performed before and after aging and the respective changes were calculated. Kruskal-Wallis tests, paired t-tests, one-way ANOVA and Bonferroni post-hoc tests were used for statistical analysis (a = 0.05). Results: Color changes ranged from 3.03 to 4.13 after coffee immersion, from 1.33 to 2.55 after thermocycling and from 1.02 to 2.75 after photoaging. No statistically significant differences for Delta E*ab were found among materials after coffee immersion and thermocycling (p>0.05). Gloss changes ranged from-5.7 to-1.6 GU after coffee immersion, from-2.3 to 0.1 GU after thermocycling and from-4.4 to 0.5 GU after photoaging. No sig-nificant differences in gloss changes were found among materials after aging (p>0.05). Tetric CAD demonstrated the significantly lower gloss and the higher surface roughness after polishing. Except for gloss after thermocy-cling, aging procedures caused significant alteration of gloss and surface roughness parameters from baseline levels. Conclusions: Aging procedures caused perceptible but acceptable color changes and small but visible gloss changes, while surface roughness parameters of the tested CAD/CAM composite materials were significantly affected by aging. Clinical significance: Aging procedures affected CAD/CAM composite materials indicating that these materials may be prone to color and surface alterations in the oral environment that could compromise the esthetics and the performance of the restorations. Clinical studies are needed to investigate the long-term behavior of the newly introduced CAD/CAM materials.
引用
收藏
页数:7
相关论文
共 57 条
[1]   Color stainability of CAD/CAM and nanocomposite resin materials [J].
Acar, Ozlem ;
Yilmaz, Burak ;
Altintas, Subutay Han ;
Chandrasekaran, Indumathi ;
Johnston, William M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (01) :71-75
[2]   In Vitro Evaluation of Translucency and Color Stability of CAD/CAM Polymer-Infiltrated Ceramic Materials after Accelerated Aging [J].
Al Amri, Mohammad D. ;
Labban, Nawaf ;
Alhijji, Saleh ;
Alamri, Hassan ;
Iskandar, Mounir ;
Platt, Jeffrey A. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (04) :318-328
[3]   Stain susceptibility of composite and ceramic CAD/CAM blocks versus direct resin composites with different resinous matrices [J].
Alharbi, Amal ;
Ardu, Stefano ;
Bortolotto, Tissiana ;
Krejci, Ivo .
ODONTOLOGY, 2017, 105 (02) :162-169
[4]  
[Anonymous], 2004, 153 CIE
[5]  
[Anonymous], 2018, D53214 ASTM, P1
[6]  
[Anonymous], 2018, TETRIC CAD SCI DOCUM
[7]  
[Anonymous], 2016, TR28642 ISO, P1
[8]  
[Anonymous], SHOFU Block Disk HC
[9]  
[Anonymous], 1998, ATLAS SUNTEST B ATLA
[10]  
[Anonymous], 2014, ISO 2813