Development and validation of online SPE purification coupled to HILIC-fluorescence-MS analysis for the characterization of N-glycans

被引:4
|
作者
Helali, Yosra [1 ]
Bourez, Axelle [1 ]
Marchant, Arnaud [2 ]
Vander Heyden, Yvan [3 ]
Van Antwerpen, Pierre [1 ]
Delporte, Cedric [1 ]
机构
[1] Univ Libre Bruxelles ULB, Analyt Platform Fac Pharm, Bioanal & Drug Discovery Unit, Fac Pharm,RD3, Bld Triomphe,Campus Plaine,CP 205-5, B-1050 Brussels, Belgium
[2] Univ Libre Bruxelles, Unvers libre Bruxelles, 900 Route Lennik, B-1070 Brussels, Belgium
[3] Vrije Univ Brussel VUB, Dept Analyt Chem, Appl Chemometr & Mol Modelling, Laarbeeklaan 103, B-1090 Jette, Belgium
关键词
Online SPE; N-Glycosylation; HILIC; Procainamide; Biotherapeutics; IgG; Mass spectrometry; Fluorescence detection; IMMUNOGLOBULIN-G; GLYCOSYLATION; ANTIBODIES; IDENTIFICATION; PROCAINAMIDE; IMPACT; IGG1;
D O I
10.1016/j.talanta.2023.125541
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
N-glycans of therapeutic glycoproteins is a critical quality attribute to be addressed. We developed a sensitive method for N-glycan characterization using procainamide (ProcA) labelling and online solid phase extraction (online SPE). N-glycans were enzymatically released, then labeled with ProcA and cleaned up via the online SPE using HILIC chemistry (online HILIC SPE). Two preparation protocols were optimized: a short one (1 h 30) and a long one (18 h). Furthermore, the developed approach was compared to RapiFluor-MS (RFMS) kit (from Waters) and to InstantPC kit (from Agilent) which both include a classical HILIC mu Elution plate SPE purification. Samples were analyzed using HILIC separation coupled to fluorescence and MS detection (HILIC-FLD-MS) with or without the online HILIC SPE. During the validation, repeatability, intermediate precision, stability, response function and injection volume were tested. Human IgG mix (Multigam (R)) and NIST mAb standard were used as references as their glycoprofiles are well described. A comparison of three batches of a rituximab biosimilar (Truxima (R)) and one batch of its originator (MabThera (R)) was also performed. Online HILIC SPE sample cleanup shows a higher sensitivity and repeatability compared to the classical HILIC mu Elution SPE. Our online HILIC SPE approach also offers the highest MS signal compared to both commercial kits. However, InstantPC shows the highest FLD signal. The analyses of rituximab samples were in line with the literature showing the efficiency of the method for N-glycan monitoring of biotherapeutics. In conclusion, the results demonstrated the usefulness and ease of application of the developed protocol with the online HILIC SPE purification.
引用
收藏
页数:10
相关论文
共 16 条
  • [1] HILIC analysis of fluorescence-labeled N-glycans from recombinant biopharmaceuticals
    Melmer, Michael
    Stangler, Thomas
    Schiefermeier, Mark
    Brunner, Werner
    Toll, Hansjoerg
    Rupprechter, Alfred
    Lindner, Wolfgang
    Premstaller, Andreas
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (02) : 905 - 914
  • [2] HILIC analysis of fluorescence-labeled N-glycans from recombinant biopharmaceuticals
    Michael Melmer
    Thomas Stangler
    Mark Schiefermeier
    Werner Brunner
    Hansjörg Toll
    Alfred Rupprechter
    Wolfgang Lindner
    Andreas Premstaller
    Analytical and Bioanalytical Chemistry, 2010, 398 : 905 - 914
  • [3] Enhanced sensitivity of LC-MS analysis of permethylated N-glycans through online purification
    Desantos-Garcia, Janie L.
    Khalil, Sarah I.
    Hussein, Ahmed
    Hu, Yunli
    Mechref, Yehia
    ELECTROPHORESIS, 2011, 32 (24) : 3516 - 3525
  • [4] Rapid Preparation of Released N-Glycans for HILIC Analysis Using a Labeling Reagent that Facilitates Sensitive Fluorescence and ESI-MS Detection
    Lauber, Matthew A.
    Yu, Ying-Qing
    Brousmiche, Darryl W.
    Hua, Zhengmao
    Koza, Stephan M.
    Magnelli, Paula
    Guthrie, Ellen
    Taron, Christopher H.
    Fountain, Kenneth J.
    ANALYTICAL CHEMISTRY, 2015, 87 (10) : 5401 - 5409
  • [5] LC-MS/MS analysis of permethylated N-glycans facilitating isomeric characterization
    Zhou, Shiyue
    Dong, Xue
    Veillon, Lucas
    Huang, Yifan
    Mechref, Yehia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (02) : 453 - 466
  • [6] LC-MS/MS analysis of permethylated N-glycans facilitating isomeric characterization
    Shiyue Zhou
    Xue Dong
    Lucas Veillon
    Yifan Huang
    Yehia Mechref
    Analytical and Bioanalytical Chemistry, 2017, 409 : 453 - 466
  • [7] Profiling and Characterization of Sialylated N-glycans by 2D-HPLC (HIAX/PGC) with Online Orbitrap MS/MS and Offline MSn
    Hanneman, Andrew J. S.
    Strand, James
    Huang, Chi-Ting
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2014, 103 (02) : 400 - 408
  • [8] A rapid and facile preparation of APTS-labeled N-glycans by combination of ion pair-assisted extraction and HILIC-SPE for routine glycan analysis
    Kinoshita, Mitsuhiro
    Nakatani, Yumi
    Yamada, Keita
    Yamamoto, Sachio
    Suzuki, Shigeo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 195
  • [9] Characterization of IgG N-Glycans Employing a Microfluidic Chip that Integrates Glycan Cleavage, Sample Purification, LC Separation, and MS Detection
    Bynum, Maggie A.
    Yin, Hongfeng
    Felts, Katherine
    Lee, Yvonne M.
    Monell, Craig R.
    Killeen, Kevin
    ANALYTICAL CHEMISTRY, 2009, 81 (21) : 8818 - 8825
  • [10] Identification and characterization of isomeric N-glycans of human alfa-acid-glycoprotein by stable isotope labelling and ZIC-HILIC-MS in combination with exoglycosidase digestion
    Mancera-Arteu, Montserrat
    Gimenez, Estela
    Barbosa, Jose
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2016, 940 : 92 - 103