Different C2 screw placement techniques with mobilization of the vertebral artery in high-riding vertebral artery cases: Cadaver dissection

被引:2
作者
Harman, Ferhat [1 ,3 ,4 ,10 ]
Oglin, Volkan [1 ]
Yilmaz, Mehmet Ozgur [5 ]
Orhun, Omer [6 ]
Baran, Oguz [7 ]
Boyukyilmaz, Seyma [2 ]
Gezercan, Yurdal [8 ]
Dalbayrak, Sedat [9 ]
Dagcinar, Adnan [1 ,3 ]
机构
[1] Marmara Univ, Fac Med, Dept Neurosurg, Istanbul, Turkiye
[2] Marmara Univ, Fac Med, Dept Emergency Med, Istanbul, Turkiye
[3] Marmara Univ, Inst Neurol Sci, Dept Neurosurg, Istanbul, Turkiye
[4] Marmara Univ, Inst Hlth Sci, Dept Neurosurg, Div Microneurosurg, Istanbul, Turkiye
[5] Univ Hlth Sci, Istanbul Training & Res Hosp, Dept Neurosurg, Istanbul, Turkiye
[6] Acıbadem Univ, Sch Med, Istanbul, Turkiye
[7] Koc Univ, Turkey Fac Med, Dept Neurosurg, Istanbul, Turkiye
[8] Adana City Training & Res Hosp, Dept Neurosurg, Adana, Turkiye
[9] Okan Univ, Fac Med, Dept Neurosurg, Istanbul, Turkiye
[10] Marmara Univ, Inst Neurol Sci, TR-34854 Istanbul, Turkiye
关键词
Axis anatomy; C2; anatomy; C2 screw placement; high-riding vertebral artery; mobilization of vertebral artery;
D O I
10.4103/jcvjs.jcvjs_73_23
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: In neurosurgery, posterior approaches intended at the craniovertebral junction are frequently used. The most popular procedures for treating upper cervical instability are C1 lateral mass, C2 pedicle, and C1-C2 transarticular screw stabilization. Due to their proximity to neural structures and the presence of the high-riding vertebral artery (VA), these techniques are complicated. The risk of VA damage can be decreased by mobilizing the VA. Using cadaveric specimens in this study was aimed to demonstrate C2 pedicle and C1-C2 transarticular screw placement with VA mobilization and a novel C2 inferior corpus screw placement technique.Methods: In this study, twelve adult cadaveric specimens and two adult dry cadaveric C2 bones were used with the permission and decision of the University Research Ethics Committee. Colored silicone was injected into the arteries and veins of these twelve cadaveric specimens. Then, muscle dissection was performed stepwise, and the C2 vertebrae of the cadavers were revealed with a surgical microscope. Each specimen and entire stages of the dissections were recorded photographically. After cadaver dissections, screw placement was performed with three different techniques. Finally, radiological imaging was done with fluoroscopy.Results: After dissection, the lateral mass of the C2 vertebra was observed, and lateral to it, the transverse process and foramen were detected with the help of a hook. Next, the posterior wall of the VA groove was removed using a 1 mm thin plate Kerrison rongeur until the VA loop could partially be observed the VA. This enables us to find the top of the loop of the VA and mobilize it inferiorly using a dissector. Following this step, the C1-2 transarticular, C2 pedicle, and the novel C2 inferior corpus screw placement can be performed safely by directly visualizing the artery.Conclusions: Due to the nearby neurologic and vascular structures, placing the C2 pedicle and C1-2 transarticular screw is a challenging procedure, especially in high-riding VA cases. However, it is possible to place the C2 pedicle, C1-2 transarticular, and novel C2 inferior corpus screw after the mobilization of the VA. This study aimed to show all of them together on a cadaver for the first time, to understand the anatomy of the C2 vertebra, and to use screw placement techniques to minimize the risk of complications.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 10 条
  • [1] Transarticular Fixation Following Mobilization of "High-Riding" Vertebral Artery
    Goel, Atul
    Prasad, Apurva
    Shah, Abhidha
    Sasane, Sumeet
    Hawaldar, Akshay
    Biswas, Chandrima
    Thomas, Antony
    [J]. OPERATIVE NEUROSURGERY, 2021, 20 (04) : E322 - E325
  • [2] Mobilization of the Vertebral Artery-Surgical Option for C2 Screw Fixation in Cases With "High Riding" Vertebral Artery
    Goel, Atul
    Rangnekar, Ranjit
    Shah, Abhidha
    Rai, Survendra
    Vutha, Ravikiran
    [J]. OPERATIVE NEUROSURGERY, 2020, 18 (06) : 648 - 651
  • [3] Is atlantoaxial instability the cause of Chiari malformation? Outcome analysis of 65 patients treated by atlantoaxial fixation
    Goel, Atul
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) : 116 - 127
  • [4] Magerl F., 1987, Cervical Spine 1, V1, P322
  • [5] Contribution of embryology in the understanding of cervical venous system anatomy within and around the transverse foramen: a review of the classical literature
    Magro, Elsa
    Senecail, Bernard
    Gentric, Jean-Christophe
    Alavi, Zarrin
    Palombi, Olivier
    Seizeur, Romuald
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (05) : 411 - 418
  • [6] New entry point for C2 screw, in posterior C1-C2 fixation (Goel-Harm's technique) significantly reducing the possibility of vertebral artery injury
    Patkar, Sushil Vasant
    [J]. NEUROLOGICAL RESEARCH, 2016, 38 (02) : 93 - 97
  • [7] Visocchi Massimiliano, 2019, Acta Neurochir Suppl, V125, P3, DOI 10.1007/978-3-319-62515-7_1
  • [8] Wang Y, 2019, World Neurosurg, V122, P1511
  • [9] Control of the vertebral artery from a posterior approach: a technical report
    Ye, Jason Y.
    Ayyash, Omar M.
    Eskander, Mark S.
    Kang, James D.
    [J]. SPINE JOURNAL, 2014, 14 (06) : E37 - E41
  • [10] Risk of vertebral artery injury: comparison between C1-C2 transarticular and C2 pedicle screws
    Yeom, Jin S.
    Buchowski, Jacob M.
    Kim, Ho-Joong
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    [J]. SPINE JOURNAL, 2013, 13 (07) : 775 - 785