New Technologies in the Assessment of Carotid Stenosis: Beyond the Color-Doppler Ultrasound-High Frame Rate Vector-Flow and 3D Arterial Analysis Ultrasound

被引:12
作者
David, Emanuele [1 ,2 ,3 ]
Martinelli, Ombretta [4 ]
Pacini, Patrizia [5 ]
Di Serafino, Marco [6 ]
Huang, Pintong [7 ]
Dolcetti, Vincenzo [5 ]
Del Gaudio, Giovanni [5 ]
Barr, Richard G. [8 ,9 ]
Renda, Maurizio [5 ]
Lucarelli, Giuseppe T. [5 ]
Di Marzo, Luca [4 ]
Clevert, Dirk A. [10 ]
Solito, Carmen [5 ]
Di Bella, Chiara [5 ]
Cantisani, Vito [5 ]
机构
[1] Sapienza Univ Rome, Dept Translat & Precis Med, I-00185 Rome, Italy
[2] Univ Catania, Univ Hosp Policlin G Rodol, Dept Med Surg Sci & Adv Technol GF Ingrassia, Radiol Unit 1, I-95123 Catania, Italy
[3] Papardo Hosp, Radiol Unit, I-98158 Messina, Italy
[4] Sapienza Univ Rome, Dept Surg Paride Stefanini, Vasc & Endovasc Surg Div, Viale Policlin 155, I-00161 Rome, Italy
[5] Sapienza Univ Rome, Policlin Umberto 1, Dept Radiol Sci Oncol & Pathol, I-00161 Rome, Italy
[6] Antonio Cardarelli Hosp, Dept Gen & Emergency Radiol, I-80131 Naples, Italy
[7] Zhejiang Univ, Affiliated Hosp 2, Dept Ultrasound Med, Sch Med, Hangzhou 242332, Peoples R China
[8] Northeastern Ohio Med Univ, Dept Radiol, Rootstown, OH 44272 USA
[9] Southwoods Imaging, Youngstown, OH 44512 USA
[10] Univ Munich, Interdisciplinary Ultrasound Ctr, Dept Radiol, Grosshadern Campus, D-81377 Munich, Germany
关键词
atherosclerotic plaque; carotid artery; color-Doppler ultrasound; contrast enhanced ultrasound; Computed Tomography Angiography (CTA); Magnetic Resonance Angiography (MRA); high frame rate vector flow; 3D arterial analysis ultrasound; CONTRAST-ENHANCED ULTRASOUND; IN-VIVO; PLAQUE; NEOVASCULARIZATION; ATHEROSCLEROSIS; RECOMMENDATIONS; ENDARTERECTOMY; METAANALYSIS; SYMPTOMS; RISK;
D O I
10.3390/diagnostics13081478
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Atherosclerotic plaque in the carotid artery is the main cause of ischemic stroke, with a high incidence rate among people over 65 years. A timely and precise diagnosis can help to prevent the ischemic event and decide patient management, such as follow up, medical, or surgical treatment. Presently, diagnostic imaging techniques available include color-Doppler ultrasound, as a first evaluation technique, computed tomography angiography, which, however, uses ionizing radiation, magnetic resonance angiography, still not in widespread use, and cerebral angiography, which is an invasively procedure reserved for therapeutically purposes. Contrast-enhanced ultrasound is carving out an important and emerging role which can significantly improve the diagnostic accuracy of an ultrasound. Modern ultrasound technologies, still not universally utilized, are opening new horizons in the arterial pathologies research field. In this paper, the technical development of various carotid artery stenosis diagnostic imaging modalities and their impact on clinical efficacy is thoroughly reviewed.
引用
收藏
页数:14
相关论文
共 56 条
[1]   IMAGING METHODS FOR ULTRASOUND CONTRAST AGENTS [J].
Averkiou, Michalakis A. ;
Bruce, Matthew F. ;
Powers, Jeffry E. ;
Sheeran, Paul S. ;
Burns, Peter N. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (03) :498-517
[2]   Carotid Vessel Wall Imaging on CTA [J].
Baradaran, H. ;
Gupta, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (03) :380-386
[3]   Vascular Imaging in Stroke: Comparative Analysis [J].
Barlinn, Kristian ;
Alexandrov, Andrei V. .
NEUROTHERAPEUTICS, 2011, 8 (03) :340-348
[4]   Role of CEUS in Vascular Pathology [J].
Cantisani, Vito ;
Di Leo, Nicola ;
David, Emanuele ;
Clevert, Dirk-Andre .
ULTRASCHALL IN DER MEDIZIN, 2021, 42 (04) :348-361
[5]   EVAR: Benefits of CEUS for monitoring stent-graft status [J].
Cantisani, Vito ;
Grazhdani, Hektor ;
Clevert, Dirk-Andre ;
Iezzi, Roberto ;
Aiani, Luca ;
Martegani, Alberto ;
Fanelli, Fabrizio ;
Di Marzo, Luca ;
Wlderk, Andrea ;
Cirelli, Carlo ;
Catalano, Carlo ;
Di Leo, Nicola ;
Di Segni, Mattia ;
Malpassini, Flavio ;
D'Ambrosio, Ferdinando .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) :1658-1665
[6]   Carotid Artery Stenosis: Accuracy of Noninvasive Tests-Individual Patient Data Meta-Analysis [J].
Chappell, Francesca M. ;
Wardlaw, Joanna M. ;
Young, Gavin R. ;
Gillard, Jonathan H. ;
Roditi, Giles H. ;
Yip, Brigitte ;
Pell, Jill P. ;
Rothwell, Peter M. ;
Brown, Martin M. ;
Gough, Michael J. ;
Randall, Marc S. .
RADIOLOGY, 2009, 251 (02) :493-502
[7]   Cardiac Magnetic Resonance Features of the Disruption-Prone and the Disrupted Carotid Plaque [J].
Chu, Baocheng ;
Ferguson, Marina S. ;
Chen, Huijun ;
Hippe, Daniel S. ;
Kerwin, William S. ;
Canton, Gador ;
Yuan, Chun ;
Hatsukami, Thomas S. .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (07) :883-896
[8]   Improved carotid atherosclerotic plaques imaging with contrast-enhanced ultrasound (CEUS) [J].
Clevert, D. A. ;
Sommer, W. H. ;
Helck, A. ;
Saam, T. ;
Reiser, M. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 48 (1-3) :141-148
[9]   Contrast-enhanced ultrasound imaging of the carotid artery [J].
Clevert, D. -A. ;
Helck, A. ;
Paprottka, P. M. ;
Reiser, M. F. ;
Jung, E. M. .
RADIOLOGE, 2011, 51 (06) :483-489
[10]   MR Carotid Plaque Imaging and Contrast-Enhanced MR Angiography Identifies Lesions Associated with Recent Ipsilateral Thromboembolic Symptoms: An In Vivo Study at 3T [J].
DeMarco, J. K. ;
Ota, H. ;
Underhill, H. R. ;
Zhu, D. C. ;
Reeves, M. J. ;
Potchen, M. J. ;
Majid, A. ;
Collar, A. ;
Talsma, J. A. ;
Potru, S. ;
Oikawa, M. ;
Dong, L. ;
Zhao, X. ;
Yarnykh, V. L. ;
Yuan, C. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (08) :1395-1402