Towards a hygroscopic growth calibration for low-cost PM2.5 sensors

被引:3
|
作者
Patel, Milan Y. [1 ]
Vannucci, Pietro F. [1 ]
Kim, Jinsol [2 ]
Berelson, William M. [2 ]
Cohen, Ronald C. [1 ,3 ]
机构
[1] Univ Calif Berkeley, Dept Chem, Berkeley, CA 94720 USA
[2] Univ Southern Calif, Dept Earth Sci, Los Angeles, CA 90089 USA
[3] Univ Calif Berkeley, Dept Earth & Planetary Sci, Berkeley, CA 94720 USA
关键词
AEROSOL; AMBIENT; TRENDS; LINK; PART;
D O I
10.5194/amt-17-1051-2024
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Low-cost particulate matter (PM) sensors continue to grow in popularity, but issues such as aerosol-size-dependent sensitivity drive the need for effective calibration schemes. Here we devise a time-evolving calibration method for the Plantower PMS5003 PM2.5 mass concentration measurements. We use 2 years of measurements from the Berkeley Environmental Air-quality and CO2 Network sensors deployed in San Francisco and Los Angeles in our analysis. The calibration uses a hygroscopic growth correction factor derived from kappa-K & ouml;hler theory, where the calibration parameters are determined empirically using US Environmental Protection Agency Air Quality System (EPA AQS) reference data at co-location sites during the period from 2021-2022. The parameters are found to vary cyclically through the seasons, and the seasonal cycles match changes in sulfate and elemental carbon PM composition fractions throughout the year. In both regions, the seasonal RH dependence calibration performs better than the uncalibrated data and data calibrated with the EPA's national Plantower calibration algorithm. In the San Francisco Bay Area, the seasonal RH dependence calibration reduces the root mean square error (RMSE) by similar to 40 % from the uncalibrated data and maintains a mean bias much smaller than the EPA national calibration scheme (-0.90 vs -2.73 mu g m(-3)). We also find that calibration parameters forecasted beyond those fit with the EPA reference data continue to outperform the uncalibrated data and EPA calibration data, enabling real-time application of the calibration scheme even in the absence of reference data. While the correction greatly improves the data accuracy, non-Gaussian distribution of the residuals suggests that other processes besides hygroscopic growth can be parameterized for future improvement of this calibration.
引用
收藏
页码:1051 / 1060
页数:10
相关论文
共 50 条
  • [41] Development of a calibration chamber to evaluate the performance of low-cost particulate matter sensors
    Sayahi, T.
    Kaufman, D.
    Becnel, T.
    Kaur, K.
    Butterfield, A. E.
    Collingwood, S.
    Zhang, Y.
    Gaillardon, P. -E.
    Kelly, K. E.
    ENVIRONMENTAL POLLUTION, 2019, 255
  • [42] Calibration and assessment of electrochemical low-cost sensors in remote alpine harsh environments
    Dallo, Federico
    Zannoni, Daniele
    Gabrieli, Jacopo
    Cristofanelli, Paolo
    Calzolari, Francescopiero
    de Blasi, Fabrizio
    Spolaor, Andrea
    Battistel, Dario
    Lodi, Rachele
    Cairns, Warren Raymond Lee
    Fjaeraa, Ann Mari
    Bonasoni, Paolo
    Barbante, Carlo
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2021, 14 (09) : 6005 - 6021
  • [43] Observation of PM2.5 using a combination of satellite remote sensing and low-cost sensor network in Siberian urban areas with limited reference monitoring
    Lin, Changqing
    Labzovskii, Lev D.
    Mak, Hugo Wai Leung
    Fung, Jimmy C. H.
    Lau, Alexis K. H.
    Kenea, Samuel Takele
    Bilal, Muhhamad
    Vande Hey, Joshua D.
    Lu, Xingcheng
    Ma, Jun
    ATMOSPHERIC ENVIRONMENT, 2020, 227
  • [44] A Deep Calibration Method for Low-Cost Air Monitoring Sensors With Multilevel Sequence Modeling
    Yu, Haomin
    Li, Qingyong
    Wang, Rao
    Chen, Zechuan
    Zhang, Yingjun
    Geng, Yangli-ao
    Zhang, Ling
    Cui, Houxin
    Zhang, Ke
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (09) : 7167 - 7179
  • [45] Climatology and calibration of MERRA-2 PM2.5 components over China
    Zhao, Qiuyue
    Zhao, Wei
    Bi, Jun
    Ma, Zongwei
    ATMOSPHERIC POLLUTION RESEARCH, 2021, 12 (02) : 357 - 366
  • [46] Laboratory assessment of low-cost PM monitors
    Manikonda, Abhisek
    Zikova, Nadezda
    Hopke, Philip K.
    Ferro, Andrea R.
    JOURNAL OF AEROSOL SCIENCE, 2016, 102 : 29 - 40
  • [47] Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
    Cho, Hyuntae
    Baek, Yunju
    SENSORS, 2021, 21 (18)
  • [48] Field Evaluation of Low-Cost Particulate Matter Sensors in Beijing
    Mei, Han
    Han, Pengfei
    Wang, Yinan
    Zeng, Ning
    Liu, Di
    Cai, Qixiang
    Deng, Zhaoze
    Wang, Yinghong
    Pan, Yuepeng
    Tang, Xiao
    SENSORS, 2020, 20 (16) : 1 - 17
  • [49] Evaluation and calibration of low-cost particulate matter sensors for respirable coal mine dust monitoring
    Feng, Zikang
    Zheng, Lina
    Zhang, Xuehan
    Liu, Jia
    Xue, Ning
    Wang, Mengmeng
    AEROSOL SCIENCE AND TECHNOLOGY, 2024, 58 (02) : 158 - 169
  • [50] The BErkeley Atmospheric CO2 Observation Network: field calibration and evaluation of low-cost air quality sensors
    Kim, Jinsol
    Shusterman, Alexis A.
    Lieschke, Kaitlyn J.
    Newman, Catherine
    Cohen, Ronald C.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (04) : 1937 - 1946