Development of a Biosensor for the Detection of Glucose Levels in Saliva Based on the Oxidation and Detection of Hydrogen Peroxide

被引:3
作者
Sanchez-Hernandez, Fernando [1 ]
Martinez-Guerrero, Esteban [1 ]
Araujo-Palomo, Elsie Evelyn [2 ]
Aguilera-Galicia, Cuauhtemoc R. [1 ]
Chavez-Hurtado, Jose Luis [1 ]
Lopez-Cardenas, Patricia G. [2 ]
Ramirez-Angulo, Jaime [3 ]
机构
[1] Inst Tecnol & Estudios Super Occidente ITESO, Dept Elect Sistemas & Informat, Tlaquepaque, Jalisco, Mexico
[2] Inst Tecnol & Estudios Super Occidente ITESO, Dispositivos & Mat Avanzados, Dept Matemat & Fis, Tlaquepaque, Jalisco, Mexico
[3] New Mexico State Univ, SNI III Mexico, El Paso, TX USA
来源
2023 IEEE LATIN AMERICAN ELECTRON DEVICES CONFERENCE, LAEDC | 2023年
关键词
Diabetes Mellitus; Hydrogen peroxide; Cycle Voltamperometry; Nano-Wire sensor; LUMINOL; SENSORS; ACID;
D O I
10.1109/LAEDC58183.2023.10209133
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents the experimental results of cyclic voltammetry tests that correlate an electric current and the concentration of hydrogen peroxide within a controlled solution. As the concentration of hydrogen peroxide increases in the managed solution, so does the electric intensity. The goal of this data allows us to corroborate that the proposed biosensor is a reproducible and potential alternative, painless, and non-invasive method for monitoring glucose levels in patients who have diabetes. The transducer is a novel Ni Polycarbonate Track Etch nanowire sensor with a high sensitivity to detect low hydrogen peroxide in human fluids.
引用
收藏
页数:4
相关论文
共 27 条
[1]  
[Anonymous], 2014, CBC 0118
[2]  
[Anonymous], 2019, Diabetes
[3]  
Castagnola M, 2011, ACTA OTORHINOLARYNGO, V31, P347
[4]  
Control D. I., 2015, DIABETES CONTRO 1001
[5]  
Dharmakeerthi K. I., 2021, MALAYSIAN J MED HLTH, V17
[6]   Single-layer MnO2 nanosheets for sensitive and selective detection of glutathione by a colorimetric method [J].
Di, Weihua ;
Zhang, Xiang ;
Qin, Weiping .
APPLIED SURFACE SCIENCE, 2017, 400 :200-205
[7]   Accuracy of salivary glucose assessment in diagnosis of diabetes and prediabestes [J].
Fares, Samar ;
Said, Marwa Sayed Mohamed ;
Ibrahim, Walaa ;
Amin, Tarek T. ;
Saad, Nagwa Eid Sobhy .
DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2019, 13 (02) :1543-1547
[8]   Ag nanoparticle-catalyzed chemiluminescent reaction between luminol and hydrogen peroxide [J].
Guo, Ji-Zhao ;
Cui, Hua ;
Zhou, Wei ;
Wang, Wei .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2008, 193 (2-3) :89-96
[9]   Electrochemical glucose sensors and their applications in diabetes management [J].
Heller, Adam ;
Feldman, Ben .
CHEMICAL REVIEWS, 2008, 108 (07) :2482-2505
[10]   Diabetes mellitus in Mexico. Status of the epidemic [J].
Hernandez-Avila, Mauricio ;
Pablo Gutierrez, Juan ;
Reynoso-Noveron, Nancy .
SALUD PUBLICA DE MEXICO, 2013, 55 :S129-S136