Induced Current Electro-Thermal Imaging for Breast Tumor Detection: A Numerical and Experimental Study

被引:2
作者
Tanriverdi, Volkan [1 ]
Gencer, Nevzat G. [1 ]
机构
[1] Middle East Tech Univ, Elect & Elect Engn Dept, TR-06800 Ankara, Turkiye
关键词
Biomedical active thermography; Breast cancer detection; Breast electrical conductivity; Breast infrared imaging; Tumor diagnosis; ELECTRICAL-CONDUCTIVITY; DIELECTRIC-PROPERTIES; THERMAL-PROPERTIES; THERMOGRAPHY; RESISTIVITY; MAMMOGRAPHY; TOMOGRAPHY; SIMULATION; POTATOES; TISSUES;
D O I
10.1007/s10439-024-03445-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study proposes using magnetically induced currents in medical infrared imaging to increase the temperature contrast due to the electrical conductivity differences between tumors and healthy tissues. There are two objectives: (1) to investigate the feasibility of this active method for surface and deep tumors using numerical simulations, and (2) to demonstrate the use of this method through different experiments conducted with phantoms that mimic breast tissues. Tumorous breasts were numerically modeled and simulated in active and passive modes. At 750 kHz, the applied current was limited for breast tissue-tumor conductivities (0.3 S/m and 0.75 S/m) according to the local specific absorption rate limit of 10 W/kg. Gelatin-based and mashed potato phantoms were produced to mimic tumorous breast tissues. In the simulation studies, the induced current changed the temperature contrast on the imaging surface, and the tumor detection sensitivity increased by 4 mm. An 11-turn 70-mm-long solenoid coil was constructed, 20 A current was applied for deep tumors, and a difference of up to 0.4 circle\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>\circ$$\end{document}C was observed in the tumor location compared with the temperature in the absence of the tumor. Similarly, a 23-turn multi-layer coil was constructed, and a temperature difference of 0.4 circle\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$<^>\circ$$\end{document}C was observed. The temperature contrast on the body surface changed, and the tumor detection depth increased with the induced currents in breast IR imaging. The proposed active thermal imaging method was validated using numerical simulations and in vitro experiments.
引用
收藏
页码:1078 / 1090
页数:13
相关论文
共 50 条
[21]   A thermoacoustic imaging system with variable curvature and multi-dimensional detection adapted to breast tumor screening [J].
Zhao, Yan ;
Ji, Zhong ;
Qin, Baohua ;
Xing, Da .
JOURNAL OF APPLIED PHYSICS, 2018, 124 (14)
[22]   Differential Microwave Imaging of Breast Pair for Tumor Detection [J].
Abbosh, A. M. ;
Mohammed, B. ;
Bialkowski, K. .
2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, :63-64
[23]   Imaging Tumor Vascularization for Detection and Diagnosis of Breast Cancer [J].
Heijblom, M. ;
Klaase, J. M. ;
van den Engh, F. M. ;
van Leeuwen, T. G. ;
Steenbergen, W. ;
Manohar, S. .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (06) :607-623
[24]   Thermal modeling for breast tumor detection using thermography [J].
Mukhmetov, O. ;
Igali, D. ;
Mashekova, A. ;
Zhao, Y. ;
Ng, E. Y. K. ;
Fok, S. C. ;
Teh, S. L. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 161
[25]   Analysis of thyroid thermographic images for detection of thyroid tumor: An experimental-numerical study [J].
Bahramian, Farshad ;
Mojra, Afsaneh .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (06)
[26]   MICROWAVE-INDUCED THERMOACOUSTIC IMAGING FOR EARLY BREAST CANCER DETECTION [J].
Ji, Zhong ;
Fu, Yong ;
Yang, Sihua .
JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2013, 6 (01)
[27]   Thermal Imaging-An Emerging Modality for Breast Cancer Detection: A Comprehensive Review [J].
Hakim, Aayesha ;
Awale, R. N. .
JOURNAL OF MEDICAL SYSTEMS, 2020, 44 (08)
[28]   Microwave and Induced Thermoacoustic Dual Imaging for Potential Breast Cancer Detection [J].
Wang, Bingwen ;
Guo, Ziwen ;
Zhao, Zhiqin ;
Chen, Yifan ;
Kosmas, Panagiotis .
PROCEEDINGS OF THE 2018 IEEE 7TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION (APCAP), 2018, :175-178
[29]   Potential of MREIT Conductivity Imaging to Detect Breast Cancer: Experimental and Numerical Simulation Studies [J].
Sajib, Saurav Z. K. ;
Kim, Hyung Joong ;
Kim, Young Tae ;
Jeong, Woo Chul ;
Oh, Tong In ;
Woo, Eung Je .
2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, :440-443
[30]   Thermal analysis of induced damage to the healthy cell during RFA of breast tumor [J].
Singh, Sundeep ;
Bhowmik, Arka ;
Repaka, Ramjee .
JOURNAL OF THERMAL BIOLOGY, 2016, 58 :80-90