The Diagnostic Value of Optical Coherence Tomography for Detecting Glaucoma in High Myopia

被引:3
|
作者
Zhang, Yan [1 ,2 ]
Wang, Wenxing [1 ,2 ]
Chen, Jiawei [1 ,2 ]
Huang, Chukai [1 ,2 ,3 ,4 ]
机构
[1] Shantou Univ, Joint Shantou Int Eye Ctr, Dongxiabei Rd,Jinping Dist, Shantou, Peoples R China
[2] Chinese Univ Hong Kong, Dongxiabei Rd,Jinping Dist, Shantou, Peoples R China
[3] Shantou Univ, Joint Shantou Int Eye Ctr, Shantou, Peoples R China
[4] Chinese Univ Hong Kong, Shantou, Peoples R China
关键词
high myopia; high myopia with glaucoma; optical coherence tomography; retinal nerve fiber layer; ganglion cell inner plexiform layer; macular ganglion cell complex; retinal thickness; NERVE-FIBER LAYER; GANGLION-CELL COMPLEX; OPEN-ANGLE GLAUCOMA; SD-OCT; RETINAL THICKNESS; DOMAIN; ABILITY; EYES; PARAMETERS; PERFORMANCE;
D O I
10.1097/IJG.0000000000002198
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis:Glaucomatous changes in high myopia are difficult to detect due to the similarity of functional and structural alteration in both disease. Optical coherence tomography (OCT) shows relatively high diagnostic accuracy in glaucoma with high myopia (HM). Purpose:This study aims to evaluate the thickness differences of OCT parameters between HM and HM with glaucoma (HMG), and to verify which parameters have a higher diagnostic value on this issue according to area under the receiver operating characteristic (AUROC) curve. Materials and Methods:A comprehensive literature search was performed on PubMed, Embase, Medline, Cochrane, CNKI, and Wanfang. Eligible articles were identified by reviewing the retrieved results. The weighted mean difference and 95% CI for continuous outcomes and pooled AUROC were calculated. Results:Fifteen studies with a total of 1304 eyes, including 569 high myopia and 735 HMG were comprised in this meta-analysis. Our results showed that, in comparison with HM, HMG had a significantly thinner thickness for retinal nerve fiber layer except for nasal sector, macular ganglion cell inner plexiform layer thickness except for superior sector and macular ganglion cell complex thickness. In contrast, the inferior sector and average thickness of retinal nerve fiber layer, macular ganglion cell complex and ganglion cell inner plexiform layer had relatively high AUROC. Conclusion:Based on the current study of retinal OCT measurement differences between HM and HMG, ophthalmologists should pay more attention to the thinning in inferior sector and the average thickness of macular and optic disc during the management of HM.
引用
收藏
页码:426 / 434
页数:9
相关论文
共 50 条
  • [1] Effect of high myopia on glaucoma diagnostic parameters measured with optical coherence tomography
    Kita, Yoshiyuki
    Kita, Ritsuko
    Takeyama, Asuka
    Tomita, Goji
    Goldberg, Ivan
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (08): : 722 - 728
  • [2] The Diagnostic Value of Optical Coherence Tomography Angiography in Glaucoma
    Koutropoulou, Nikolitsa
    Panos, Georgios D.
    CURRENT MEDICAL IMAGING, 2021, 17 (10) : 1179 - 1182
  • [3] Diagnostic performance of wide-field optical coherence tomography angiography in detecting open-angle glaucoma in high myopia
    Zhang, Yinhang
    Wang, Deming
    Lin, Fengbin
    Song, Yunhe
    Chen, Yu
    Peng, Yuying
    Chen, Meiling
    Liu, Yuhong
    Jiang, Jiaxuan
    Yang, Zefeng
    Li, Fei
    Zhang, Xiulan
    ACTA OPHTHALMOLOGICA, 2024, 102 (02) : E168 - E177
  • [4] Optical coherence tomography angiography compared with optical coherence tomography for detection of glaucoma progression with high myopia
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [5] Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography for Detection of Early Glaucoma With High Myopia
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    Huang, Tzu-Lun
    Hsu, Yung-Ray
    FRONTIERS IN MEDICINE, 2022, 8
  • [6] Optical Coherence Tomography in High Myopia
    Schuman, Joel S.
    JAMA OPHTHALMOLOGY, 2016, 134 (09) : 1040 - 1040
  • [7] Which Optical Coherence Tomography Parameter, If Any, Identifies Glaucoma in High Myopia?
    Asrani, Sanjay
    Thompson, Atalie C.
    JAMA OPHTHALMOLOGY, 2023, 141 (07) : 639 - 640
  • [8] Comparison of Optical Coherence Tomography Structural Parameters for Diagnosis of Glaucoma in High Myopia
    Jeong, Yoon
    Kim, Young Kook
    Jeoung, Jin Wook
    Park, Ki Ho
    JAMA OPHTHALMOLOGY, 2023, 141 (07) : 631 - 639
  • [9] Macular parameters of Stratus optical coherence tomography for assessing glaucoma in high myopia
    Hung, Kuo-Chi
    Wu, Pei-Chang
    Chang, Hsueh-Wen
    Lai, Ing-Chou
    Tsai, Jen-Chia
    Lin, Pei-Wen
    Teng, Mei-Ching
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2015, 98 (01) : 39 - 44
  • [10] New options of high resolution optical coherence tomography in glaucoma diagnostic
    Schulze, A.
    Lamparter, J.
    Hoffmann, E. M.
    OPHTHALMOLOGE, 2009, 106 (08): : 702 - +