Surface Coating Effect on Corrosion Resistance of Titanium Alloy Bone Implants by Anodizing Method

被引:7
作者
Ningrum, Eva Oktavia [1 ]
Khoiroh, Ianatul [2 ]
Nastiti, Hanifah Inas [1 ]
Affan, Ryan Anindya [1 ]
Karisma, Achmad Dwitama [1 ]
Agustiani, Elly [1 ]
Surono, Agus [1 ]
Suroto, Heri [3 ]
Suprapto, S. [1 ]
Taji, Lulu Sekar [1 ]
Widiyanto, Sinung [4 ]
机构
[1] Inst Teknol Sepuluh Nopember, Fac Vocat Studies, Dept Ind Chem Engn, Kampus ITS Sukolilo, Surabaya 60111, Indonesia
[2] Univ Nottingham Malaysia, Fac Sci & Engn, Dept Chem & Environm Engn, Semenyih 43500, Selangor, Malaysia
[3] Airlangga Univ, Dr Soetomo Gen Acad Hosp, Fac Med, Orthoped & Traumatol Dept, Jl Mayjen Prof Dr Moestopo 47, Surabaya 60132, Indonesia
[4] Hang Tuah Univ, Fac Engn & Marine Sci, Magister Ocean Engn, Jl Arief Rahman Hakim 150, Surabaya 60111, Indonesia
关键词
Anodizing; Corrosion resistance; Titanium oxide; Ti-6Al-4V alloy; TI-6AL-4V ALLOY; ANODIZATION; BEHAVIOR; LAYERS;
D O I
10.14716/ijtech.v14i4.6146
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In the presented work, the formation of anodic oxide film on Ti-6Al-4V ELI (Extra Low Interstitial) alloy in 0.02 M trisodium phosphate (Na3PO4) electrolyte solution using various voltages were investigated. The color produced by the anodizing, the intensity of TiO2 content, the thickness of the oxide layer, and the corrosion rate were examined. It was obtained that the color appearance of Ti-6Al-4V ELI could be changed easily by altering the applied voltages. The higher the voltage applied in the anodizing process, the thicker the titanium oxide layer formed. The corrosion resistance analysis in a Simulated Body Fluid revealed that the non-anodized specimen showed a higher corrosion rate compared to the anodized specimen. The increase of oxide layer thickness leads to a significant decrease in corrosion rate and consequently increases the corrosion resistance. In addition, the anodized sample achieved the highest corrosion resistance at 15 V.
引用
收藏
页码:749 / 760
页数:12
相关论文
共 38 条
  • [1] Al-Mobarak NA, 2014, INT J ELECTROCHEM SC, V9, P32
  • [2] Alphanoda A.F., 2017, Jurnal Teknologi Rekayasa, V1, DOI [10.31544/jtera.v1.i1.2016.1-6, DOI 10.31544/JTERA.V1.I1.2016.1-6]
  • [3] Structural, Morphological, and Electrochemical Corrosion Properties of TiO2 Formed on Ti6Al4V Alloys by Anodization
    Atmani, Djamila
    Saoula, Nadia
    Abdi, Abderrezak
    Azzaz, Mohamed
    Wang, Youling
    Mohamedi, Mohamed
    [J]. CRYSTAL RESEARCH AND TECHNOLOGY, 2018, 53 (12)
  • [4] Bakr M., 2021, EGYPTIAN J HISTOLOGY, V45, P849
  • [5] Bhola R., 2011, ELECT PRECISION TREA, V47, P75
  • [6] Effect of Cinnamaldehyde, an Anti-Inflammatory Agent, on the Surface Characteristics of a Plaster of Paris - CaCO3 Hydrogel for Bone Substitution in Biomedicine
    Dewi, Anne Handrini
    Yulianto, Dedy Kusuma
    Ana, Ika Dewi
    Rochmadi
    Siswomihardjo, Widowati
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 963 - 973
  • [7] Fadl-allah S. A., 2013, J BIOMATERIALS NANOB, V04, P74, DOI DOI 10.4236/JBNB.2013.41010
  • [8] Gabor R., 2020, SCI REPORTS
  • [9] Dental Implant Monitoring Using Resonance Frequency Analysis (RFA) and Cone Beam Computed Tomography (CBCT) Measurement
    Genisa, Maya
    Shuib, Solehuddin
    Rajion, Zainul Ahmad
    Mohamad, Dasmawati
    Arief, Erry Mochamad
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY, 2020, 11 (05) : 1015 - 1024
  • [10] Corrosion behavior of electrochemically assembled nanoporous titania for biomedical applications
    Indira, K.
    Mudali, U. Kamachi
    Rajendran, N.
    [J]. CERAMICS INTERNATIONAL, 2013, 39 (02) : 959 - 967