Evaluation of pericardium patch graft thickness in patients with Ahmed glaucoma valve implantation: an anterior segment OCT study

被引:1
作者
Akbas, Yusuf Berk [1 ]
Alagoz, Nese [2 ]
Sari, Cem [2 ]
Altan, Cigdem [2 ]
Yasar, Tekin [2 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Ophthalmol, Istanbul, Turkiye
[2] Univ Hlth Sci, Beyoglu Eye Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkiye
关键词
Ahmed Glaucoma Valve; Anterior segment optical coherence tomography; Exposure; Pericardium patch graft; Glaucoma drainage devices; DRAINAGE DEVICE; TUBE EXPOSURE; CLINICAL-EXPERIENCE; ENDOPHTHALMITIS; OUTCOMES;
D O I
10.1007/s10384-024-01051-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the changes in thickness of tissues, specifically the pericardium patch graft (PPG) covering the silicone tube in Ahmed Glaucoma Valve (AGV) surgery.Study design Prospective observational study.Methods This study included cases with refractory glaucoma that underwent AGV implantation with PPG coverage. Conjunctival epithelium, stroma and PPG thickness covering the tube were measured using anterior segment optical coherence tomography (AS-OCT) at 1, 6 and 12 months. Additionally, the same measurements were taken 1500 mu m away from the tube as a control for the central measurements.Results Twenty-seven eyes of 27 patients were evaluated in the study. Although PPG thickness decreased significantly in both regions, the amount of reduction was more pronounced centrally. Centrally, the reduction rate was 21.2% and 34.8% during the 1-6 months period and 6-12 months period, while peripherally it was 3.5% and 5.1%, respectively. No change was observed in the thickness of the epithelium during the follow-up period. There was a significant thinning of the stroma in the central and peripheral regions during the 1-6 months period (30.5% and 17%, respectively). No cases of exposure were observed during the follow-up period.Conclusion Although the most evident thinning of the layers covering the tube was observed in the early postoperative period, PPG showed a stable decrease even in the late period. The progressive reduction in the PPG thickness observed also in the peripheral region indicates that factors beyond mechanical forces contribute to this degenerative process. AS-OCT could be a valuable non-invasive tool in clarifying this process.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 50 条
  • [41] Use of Mitomycin C to reduce the incidence of encapsulated cysts following ahmed glaucoma valve implantation in refractory glaucoma patients: a new technique
    Zhou, Minwen
    Wang, Wei
    Huang, Wenbin
    Zhang, Xiulan
    BMC OPHTHALMOLOGY, 2014, 14
  • [42] Surgical Outcomes of Ahmed Glaucoma Valve Implantation Without Plate Sutures: A 10-Year Retrospective Study
    Kapelushnik, Noa
    Singer, Reut
    Barkana, Yaniv
    Rosenfeld, Alik
    Tucker, Yisrael
    Jaber, Wasim
    Gaton, Dan
    Leshno, Ari
    Skaat, Alon
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : 502 - 507
  • [43] Effect of guided Ahmed glaucoma valve implantation on corneal endothelial cells: A 2-year comparative study
    Chey, Ji Hyoung
    Lee, Chang Kyu
    PLOS ONE, 2023, 18 (02):
  • [44] Evaluation of Conjunctival Graft Thickness after Pterygium Surgery by Anterior Segment Optical Coherence Tomography
    Kheirkhah, Ahmad
    Adelpour, Mohsen
    Nikdel, Mojgan
    Ghaffari, Reza
    Ghassemi, Hamed
    Hashemi, Hassan
    CURRENT EYE RESEARCH, 2011, 36 (09) : 782 - 786
  • [45] Relationship between Tube Parameters and Corneal Endothelial Cell Damage after Ahmed Glaucoma Valve Implantation: A Comparative Study
    Lee, Han Min
    Kim, Kyoung Nam
    Park, Kee Sup
    Lee, Nam Ho
    Lee, Sung Bok
    Kim, Chang-Sik
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 11
  • [46] Anterior Chamber Versus Ciliary Sulcus Ahmed Glaucoma Valve Tube Placement: Longitudinal Evaluation of Corneal Endothelial Cell Profiles
    Godinho, Goncalo
    Barbosa-Breda, Joao
    Oliveira-Ferreira, Claudia
    Madeira, Carolina
    Melo, Antonio
    Falcao-Reis, Fernando
    Estrela-Silva, Sergio
    JOURNAL OF GLAUCOMA, 2021, 30 (02) : 170 - 174
  • [47] Transscleral cyclophotocoagulation with MicroPulse(R) laser versus Ahmed valve implantation in patients with advanced primary open-angle glaucoma
    Fili, Sofia
    Kontopoulou, Kalliopi
    Vastardis, Iraklis
    Perdikakis, Georgios
    Papadonta, Styliani Alexia
    Armeni, Eleni Zaira
    Kohlhaas, Markus
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (04) : 1271 - 1282
  • [48] Comparison of FP-7 and S-2 Ahmed glaucoma valve implantation in refractory glaucoma patients for short-term follow-up
    Bai Yu-jing
    Li Yi-qing
    Chai Fang
    Yang Xue-jiao
    Zhang Yi-chong
    Wei Yan-tao
    Huang Jing-jing
    Ge Jian
    Zhuo Ye-hong
    CHINESE MEDICAL JOURNAL, 2011, 124 (08) : 1128 - 1133
  • [49] Comparison of Short and Long-Tunnel Needle Track for Ahmed Glaucoma Valve Implantation in a Private Eye Center in the Philippines: A Retrospective Study
    San Pedro, Marie Jeremy B.
    Gomez, James Paul S.
    Leuenberger, Edgar U.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1691 - 1699
  • [50] Evaluation of corneal epithelial thickness in glaucomatous patients using anterior-segment optical coherence tomography
    Montorio, Daniela
    Cennamo, Gilda
    Breve, Maria A.
    Fiore, Ugo
    Reibaldi, Michele
    Morra, Vincenzo Brescia
    Cennamo, Giovanni
    JOURNAL OF BIOPHOTONICS, 2020, 13 (01)