Evaluation of pericardium patch graft thickness in patients with Ahmed glaucoma valve implantation: an anterior segment OCT study

被引:1
作者
Akbas, Yusuf Berk [1 ]
Alagoz, Nese [2 ]
Sari, Cem [2 ]
Altan, Cigdem [2 ]
Yasar, Tekin [2 ]
机构
[1] Univ Hlth Sci, Basaksehir Cam & Sakura City Hosp, Dept Ophthalmol, Istanbul, Turkiye
[2] Univ Hlth Sci, Beyoglu Eye Training & Res Hosp, Dept Ophthalmol, Istanbul, Turkiye
关键词
Ahmed Glaucoma Valve; Anterior segment optical coherence tomography; Exposure; Pericardium patch graft; Glaucoma drainage devices; DRAINAGE DEVICE; TUBE EXPOSURE; CLINICAL-EXPERIENCE; ENDOPHTHALMITIS; OUTCOMES;
D O I
10.1007/s10384-024-01051-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the changes in thickness of tissues, specifically the pericardium patch graft (PPG) covering the silicone tube in Ahmed Glaucoma Valve (AGV) surgery.Study design Prospective observational study.Methods This study included cases with refractory glaucoma that underwent AGV implantation with PPG coverage. Conjunctival epithelium, stroma and PPG thickness covering the tube were measured using anterior segment optical coherence tomography (AS-OCT) at 1, 6 and 12 months. Additionally, the same measurements were taken 1500 mu m away from the tube as a control for the central measurements.Results Twenty-seven eyes of 27 patients were evaluated in the study. Although PPG thickness decreased significantly in both regions, the amount of reduction was more pronounced centrally. Centrally, the reduction rate was 21.2% and 34.8% during the 1-6 months period and 6-12 months period, while peripherally it was 3.5% and 5.1%, respectively. No change was observed in the thickness of the epithelium during the follow-up period. There was a significant thinning of the stroma in the central and peripheral regions during the 1-6 months period (30.5% and 17%, respectively). No cases of exposure were observed during the follow-up period.Conclusion Although the most evident thinning of the layers covering the tube was observed in the early postoperative period, PPG showed a stable decrease even in the late period. The progressive reduction in the PPG thickness observed also in the peripheral region indicates that factors beyond mechanical forces contribute to this degenerative process. AS-OCT could be a valuable non-invasive tool in clarifying this process.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 50 条
  • [31] Central Corneal Thickness and Anterior Scleral Thickness in Korean Patients With Open-angle Glaucoma: An Anterior Segment Optical Coherence Tomography Study
    Yoo, Chungkwon
    Eom, Young Sub
    Suh, Young-Woo
    Kim, Yong Yeon
    JOURNAL OF GLAUCOMA, 2011, 20 (02) : 95 - 99
  • [32] Level of Vascular Endothelial Growth Factor in Aqueous Humor and Surgical Results of Ahmed Glaucoma Valve Implantation in Patients With Neovascular Glaucoma
    Kim, Yong Guk
    Hong, Samin
    Lee, Christopher Seungkyu
    Kang, Sung Yong
    Seong, Gong Je
    Ma, Kyoung Tak
    Kim, Chan Yun
    JOURNAL OF GLAUCOMA, 2009, 18 (06) : 443 - 447
  • [33] Effect of immediate shallow anterior chamber after Ahmed glaucoma valve implantation on intermediate-term intraocular pressure control
    Patil, Trupti Sudhir
    Mani, Baskaran
    Balekudaru, Shantha
    George, Ronnie J.
    Lingam, Vijaya
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2915 - 2921
  • [34] A graft-free scleral sleeve technique of Ahmed Glaucoma Valve implantation in refractory glaucoma- Rising to the challenge of COVID-19 pandemic
    Gupta, Richa
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (06) : 1623 - 1625
  • [35] Long-Term Experience of Patch Graft Failure After Ahmed Glaucoma Valve® Surgery Using Donor Dura and Sclera Allografts
    Zalta, Alan H.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2012, 43 (05) : 408 - 415
  • [36] Comparison between primary Ahmed valve implantation and primary trabeculectomy with mitomycin C in pseudophakic patients with exfoliative glaucoma
    Hwang, Su Yeong
    Ahn, Hee Bae
    Jin, Sang Wook
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (12) : 3559 - 3567
  • [37] Outcomes of Ahmed glaucoma valve implantation for steroid-induced elevated intraocular pressure in patients with retinitis pigmentosa
    Umit Eksioglu
    Caglar Oktem
    Gulten Sungur
    Mehmet Yakin
    Gulizar Demirok
    Firdevs Ornek
    International Ophthalmology, 2018, 38 : 1833 - 1838
  • [38] Anterior segment OCT for imaging PAUL® glaucoma implant patch grafts: a useful method for follow-up and risk management
    Schipper, Pascal
    Weber, Constance
    Lu, Ke
    Fan, Siqi
    Prokosch, Verena
    Holz, Frank G.
    Mercieca, Karl
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, : 1071 - 1079
  • [39] Long-term surgical outcomes of combined Ahmed glaucoma valve implantation and phacoemulsification with intraocular lens implantation for patients with glaucoma secondary to iridocorneal endothelial syndrome
    Sun, Yunxiao
    Duan, Xiaoming
    Fang, Yuxin
    Tang, Xin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [40] Outcomes of Ahmed glaucoma valve implantation for steroid-induced elevated intraocular pressure in patients with retinitis pigmentosa
    Eksioglu, Umit
    Oktem, Caglar
    Sungur, Gulten
    Yakin, Mehmet
    Demirok, Gulizar
    Ornek, Firdevs
    INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (05) : 1833 - 1838