Improved short-term outcomes for a novel, fluoroscopy-based robotic-assisted total hip arthroplasty system compared to manual technique with fluoroscopic assistance

被引:4
|
作者
Buchan, Graham B. J. [1 ]
Hecht II, Christian J. [1 ]
Sculco, Peter K. [2 ]
Chen, James B. [3 ]
Kamath, Atul F. [1 ]
机构
[1] Cleveland Clin Fdn, Orthopaed & Rheumatol Inst, Dept Orthopaed Surg, 9500 Euclid Ave, Cleveland, OH 44195 USA
[2] Hosp Special Surg, Dept Orthopaed Surg, 535 East 70th, New York, NY 10021 USA
[3] Providence Mission Hosp, Mission Orthopaed Inst, Mission Viejo, CA 92691 USA
关键词
Total hip arthroplasty (THA); Outcomes; Robotic-assisted surgery; Fluoroscopy; Robotic THA; Hip replacement; ACETABULAR COMPONENT; ORIENTATION; SURGERY;
D O I
10.1007/s00402-023-05061-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background While robotic-assisted total hip arthroplasty (RA-THA) has been associated with improved accuracy of component placement, the perioperative and early postoperative outcomes of fluoroscopy-based RA-THA systems have yet to be elucidated.Methods This retrospective cohort analysis included a consecutive series of patients who received manual, fluoroscopy-assisted THA (mTHA) and fluoroscopy-based RA-THA at a single institution. We compared rates of complications within 90 days of surgery, length of hospital stay (LOS), and visual analog scale (VAS) pain scores.Results No differences existed between groups with respect to demographic data or perioperative recovery protocols. The RA-THA cohort had a significantly greater proportion of outpatient surgeries compared to the mTHA cohort (37.4% vs. 3.8%; p < 0.001) and significantly lower LOS (26.0 vs. 39.5 h; p < 0.001). The RA-THA cohort had a smaller 90-day postoperative complication rate compared to the mTHA cohort (0.9% vs. 6.7%; p = 0.029). The RA-THA cohort had significantly lower patient-reported VAS pain scores at 2-week follow-up visits (2.5 vs. 3.3; p = 0.048), but no difference was seen after 6-week follow visits (2.5 vs. 2.8; p = 0.468).Conclusion Fluoroscopy-based RA-THA demonstrates low rates of postoperative complications, improved postoperative pain profiles, and shortened LOS when compared to manual, fluoroscopy-assisted THA.
引用
收藏
页码:501 / 508
页数:8
相关论文
共 42 条
  • [21] Robotic-assisted total hip arthroplasty utilizing a fluoroscopy-guided system resulted in improved intra-operative efficiency relative to a computerized tomography-based platform
    Ong, Christian B.
    Buchan, Graham B. J.
    Hecht II, Christian J.
    Lawrie, Charles M.
    Decook, Charles A.
    Sculco, Peter K.
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (06) : 2841 - 2847
  • [22] Robotic-assisted total hip arthroplasty utilizing a fluoroscopy-guided system produced similar cup accuracy and precision relative to a computerized tomography-based robotic platform
    Ong, Christian B.
    Buchan, Graham B. J.
    Hecht II, Christian J.
    Kanaji, Arihiko
    Kendoff, Daniel O.
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [23] Patient Satisfaction Outcomes after Robotic Arm-Assisted Total Knee Arthroplasty: A Short-Term Evaluation
    Marchand, Robert C.
    Sodhi, Nipun
    Khlopas, Anton
    Sultan, Assem A.
    Harwin, Steven F.
    Malkani, Arthur L.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2017, 30 (09) : 849 - 853
  • [24] Comparing early and mid-term outcomes between robotic-arm assisted and manual total hip arthroplasty: a systematic review
    Linsen T. Samuel
    Alexander J. Acuña
    Bilal Mahmood
    Ahmed K. Emara
    Atul F. Kamath
    Journal of Robotic Surgery, 2022, 16 : 735 - 748
  • [25] Comparing early and mid-term outcomes between robotic-arm assisted and manual total hip arthroplasty: a systematic review
    Samuel, Linsen T.
    Acuna, Alexander J.
    Mahmood, Bilal
    Emara, Ahmed K.
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2022, 16 (04) : 735 - 748
  • [26] Short-Term Total Hip Arthroplasty Outcomes in Patients With Psoriatic Arthritis or Psoriatic Skin Disease Compared to Patients With Osteoarthritis
    Mandl, Lisa A.
    Zhu, Rebecca
    Huang, Wei-Ti
    Zhang, Meng
    Alexiades, Michael M.
    Figgie, Mark P.
    Goodman, Susan M.
    ARTHRITIS & RHEUMATOLOGY, 2016, 68 (02) : 410 - 417
  • [27] Equivalent radiation exposure with robotic total hip replacement using a novel, fluoroscopic-guided (CT-free) system: case-control study versus manual technique
    Buchan, Graham
    Ong, Christian
    Hecht, Christian
    Tanous, Thomas J.
    Peterson, Blake
    Hasegawa, Akihiko
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (04) : 1561 - 1567
  • [28] Preliminary study of short-term outcomes and learning curves of robotic-assisted THA: comparison between closed platform robotic system and open platform robotic system
    Teng-Feng Zhuang
    Chong-Jie Wu
    Si-Min Luo
    Wen-Rui Wu
    Jun-Yuan Chen
    Zhen-Gang Zha
    Song-Wei Huan
    Ning Liu
    BMC Musculoskeletal Disorders, 24
  • [29] Comparison of Surgical Time, Short-term Adverse Events, and Implant Placement Accuracy Between Manual, Robotic-assisted, and Computer-navigated Total Hip Arthroplasty: A Network Meta-analysis of Randomized Controlled Trials
    Kunze, Kyle N.
    Bovonratwet, Patawut
    Polce, Evan M.
    Paul, Katlynn
    Sculco, Peter K.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS, 2022, 6 (04):
  • [30] Preliminary study of short-term outcomes and learning curves of robotic-assisted THA: comparison between closed platform robotic system and open platform robotic system
    Zhuang, Teng-Feng
    Wu, Chong-Jie
    Luo, Si-Min
    Wu, Wen-Rui
    Chen, Jun-Yuan
    Zha, Zhen-Gang
    Huan, Song-Wei
    Liu, Ning
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)