共 41 条
Determination of polyamines in urine via electrospun nanofibers-based solid-phase extraction coupled with GC-MS and application to gastric cancer patients
被引:5
作者:
Xie, Li
[1
]
Chen, Weilin
[3
]
Shu, Qing
[3
]
Xie, Wei
[4
]
Bian, Linxiao
[2
]
Deng, Guozhe
[1
]
Kang, Xuejun
[1
,5
]
Ge, Weihong
[3
,6
]
机构:
[1] Southeast Univ, Sch Biol Sci & Med Engn, Key Lab Child Dev & Learning Sci, Minist Educ, Nanjing, Peoples R China
[2] Jinling Inst Technol, Sch Anim Sci & Technol, Nanjing, Peoples R China
[3] Nanjing Drum Tower Hosp, Dept Pharm, Nanjing, Peoples R China
[4] Jiangsu Kebai Pharmaceut Technol Co Ltd, Nanjing, Peoples R China
[5] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 210096, Peoples R China
[6] Nanjing Drum Tower Hosp, Dept Pharm, Nanjing 210008, Peoples R China
基金:
美国国家科学基金会;
关键词:
gastric cancer;
ion-pairing;
polyamines;
polystyrene nanofibers;
solid-phase extraction;
ION-PAIR EXTRACTION;
CHROMATOGRAPHY-MASS SPECTROMETRY;
PERFORMANCE LIQUID-CHROMATOGRAPHY;
BIOGENIC-AMINES;
DERIVATIZATION;
MARKERS;
PLASMA;
QUANTIFICATION;
DERIVATIVES;
PROFILES;
D O I:
10.1002/jssc.202200629
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
The simultaneous determination of polyamines and their metabolites in urine samples was achieved by gas chromatography-mass spectrometry in the selected ion monitoring mode. After conjugating with the ion-pair reagent bis-2-ethylhexylphosphate in the aqueous phase, the polyamines in the samples were extracted with polystyrene nanofiber-based packed-fiber solid-phase extraction followed by a derivatization step using pentafluoropropionyl anhydride. With optimal conditions, all analytes were separated well. For analytes of putrescine, cadaverine, N-acetylputrescine, and N-acetylcadaverine, the linearity was good in the range of 0.05-500 mu mol/L (R-2 >= 0.993). While for spermidine, spermine, acetylspermidine, N-8-acetylspermidine, and N-acetylspermine, the linearity was good in the range of 0.5-500 mu mol/L (R-2 >= 0.990). The recoveries of three spiked concentrations (0.5, 5, 300 mu mol/L) were 85.6%-108.4%, and relative standard deviations for intra- and interday were in the range of 2.9%-13.4% and 4.5%-15.1%, respectively. The method was successfully applied to the analysis of urine samples of gastric cancer patients. The results showed that the levels of most polyamines and N-acetylated polyamines from the patient group were significantly higher than those from the control group. The altered concentrations of the above-mentioned metabolites suggest their role in the pathogenesis of gastric cancer, and they should be further evaluated as potential markers of gastric cancer.
引用
收藏
页数:14
相关论文