Determination of polyamines in urine via electrospun nanofibers-based solid-phase extraction coupled with GC-MS and application to gastric cancer patients

被引:5
作者
Xie, Li [1 ]
Chen, Weilin [3 ]
Shu, Qing [3 ]
Xie, Wei [4 ]
Bian, Linxiao [2 ]
Deng, Guozhe [1 ]
Kang, Xuejun [1 ,5 ]
Ge, Weihong [3 ,6 ]
机构
[1] Southeast Univ, Sch Biol Sci & Med Engn, Key Lab Child Dev & Learning Sci, Minist Educ, Nanjing, Peoples R China
[2] Jinling Inst Technol, Sch Anim Sci & Technol, Nanjing, Peoples R China
[3] Nanjing Drum Tower Hosp, Dept Pharm, Nanjing, Peoples R China
[4] Jiangsu Kebai Pharmaceut Technol Co Ltd, Nanjing, Peoples R China
[5] Southeast Univ, Sch Biol Sci & Med Engn, Nanjing 210096, Peoples R China
[6] Nanjing Drum Tower Hosp, Dept Pharm, Nanjing 210008, Peoples R China
基金
美国国家科学基金会;
关键词
gastric cancer; ion-pairing; polyamines; polystyrene nanofibers; solid-phase extraction; ION-PAIR EXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; BIOGENIC-AMINES; DERIVATIZATION; MARKERS; PLASMA; QUANTIFICATION; DERIVATIVES; PROFILES;
D O I
10.1002/jssc.202200629
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determination of polyamines and their metabolites in urine samples was achieved by gas chromatography-mass spectrometry in the selected ion monitoring mode. After conjugating with the ion-pair reagent bis-2-ethylhexylphosphate in the aqueous phase, the polyamines in the samples were extracted with polystyrene nanofiber-based packed-fiber solid-phase extraction followed by a derivatization step using pentafluoropropionyl anhydride. With optimal conditions, all analytes were separated well. For analytes of putrescine, cadaverine, N-acetylputrescine, and N-acetylcadaverine, the linearity was good in the range of 0.05-500 mu mol/L (R-2 >= 0.993). While for spermidine, spermine, acetylspermidine, N-8-acetylspermidine, and N-acetylspermine, the linearity was good in the range of 0.5-500 mu mol/L (R-2 >= 0.990). The recoveries of three spiked concentrations (0.5, 5, 300 mu mol/L) were 85.6%-108.4%, and relative standard deviations for intra- and interday were in the range of 2.9%-13.4% and 4.5%-15.1%, respectively. The method was successfully applied to the analysis of urine samples of gastric cancer patients. The results showed that the levels of most polyamines and N-acetylated polyamines from the patient group were significantly higher than those from the control group. The altered concentrations of the above-mentioned metabolites suggest their role in the pathogenesis of gastric cancer, and they should be further evaluated as potential markers of gastric cancer.
引用
收藏
页数:14
相关论文
共 41 条
[1]   Development of non-aqueous single stage derivatisation method for the determination of putrescine and cadaverine using GC-MS [J].
Awan, M. Ali .
CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2008, 6 (02) :229-236
[2]  
BARTOS D, 1975, CANCER RES, V35, P2056
[3]   The determination and characterisation of 2-naphthyloxycarbonyl chloride derivatised biogenic amines in pet foods [J].
Bassanese, Danielle N. ;
Crawford-Clark, Shona ;
Bowen, Benjamin J. ;
Henderson, Luke C. ;
Barnett, Neil W. ;
Conlan, Xavier A. .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (09) :1110-1117
[4]   ANALYSIS OF BUPRENORPHINE AND ITS N-DEALKYLATED METABOLITE IN PLASMA AND URINE BY SELECTED-ION MONITORING [J].
BLOM, Y ;
BONDESSON, U ;
ANGGARD, E .
JOURNAL OF CHROMATOGRAPHY, 1985, 338 (01) :89-98
[5]   Low-temperature derivatization followed by vortex-assisted liquid-liquid microextraction for the analysis of polyamines in Nicotiana Tabacum [J].
Cai, Kai ;
Cai, Bin ;
Xiang, Zhangmin ;
Zhao, Huina ;
Rao, Xingyi ;
Pan, Wenjie ;
Lei, Bo .
JOURNAL OF SEPARATION SCIENCE, 2016, 39 (13) :2573-2583
[6]   Polyamine catabolism and disease [J].
Casero, Robert A., Jr. ;
Pegg, Anthony E. .
BIOCHEMICAL JOURNAL, 2009, 421 :323-338
[7]   A quantitative GC-MS method for three major polyamines in postmortem brain cortex [J].
Chen, Gary G. ;
Turecki, Gustavo ;
Mamer, Orval A. .
JOURNAL OF MASS SPECTROMETRY, 2009, 44 (08) :1203-1210
[8]  
Choi MH, 2001, CLIN CHEM, V47, P143
[9]   Systematic comparisons of artificial urine formulas for in vitro cellular study [J].
Chutipongtanate, Somchai ;
Thongboonkerd, Visith .
ANALYTICAL BIOCHEMISTRY, 2010, 402 (01) :110-112
[10]   Quantification of biogenic amines in human plasma based on the derivatization with N-hydroxy-succinimidyl fluorescelin-O-acetate by high-performance liquid chromatography [J].
Deng, Ying-Hua ;
Zhang, Hua-Shan ;
Du, Xiao-Lan ;
Wang, Hong .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (6-7) :990-998