Experimental study on the passive regulation of a CO2 two-phase thermosyphon loop

被引:14
作者
Tong, Zhen [1 ]
Fang, Chunxue [1 ]
Zang, Guojian [1 ]
Wu, Hao [1 ]
机构
[1] Qingdao Univ Technol, Sch Environm & Municipal Engn, Qingdao 266033, Peoples R China
关键词
CO2; Thermosyphon loop; Experiment; Passive regulation; Operation state; BOILING HEAT-TRANSFER; CARBON-DIOXIDE; PRESSURE-DROP; PIPE SYSTEM; PERFORMANCE; EVAPORATOR; DOWNCOMER; STATES; PHASE;
D O I
10.1016/j.applthermaleng.2022.119457
中图分类号
O414.1 [热力学];
学科分类号
摘要
Vapor-liquid distribution and flow characteristics in a two-phase thermosyphon loop usually exhibit regular variation under varying working conditions, which can be referred to as passive regulation. Currently, the passive regulation law of a CO2 two-phase thermosyphon loop has not been well understood. In this study, experiments were performed to examine the passive regulation mechanism of a CO2 two-phase thermosyphon loop under different heat loads and filling ratios. Local flow visualization was adopted, combined with the measurement of operating parameters. The CO2 two-phase thermosyphon loop entered the pre-start, oscillatory, and stable operation stages successively with the increase in heat load. Vapor-liquid counterflow was observed in the downcomer in the pre-start stage. Temperature change due to thermal unbalance between the vapor and liquid can be observed along the riser or the downcomer. In the oscillatory stage, different types of oscillation were observed under different filling ratios. In the stable stage, the two-phase thermosyphon loop worked under good conditions until the heat transfer limit was reached. The two-phase thermosyphon loop reached its maximum heat transfer limit of 1200 W at a filling ratio of 45%. The normal operation heat load range of the two-phase thermosyphon loop was 380-650 W, 320-770 W, 700-1100 W, 600-1200 W, and 400-630 W for filling ratios of 20%, 25%, 40%, 45%, and 50%, respectively.
引用
收藏
页数:11
相关论文
共 40 条
[1]   Characteristic map of working mediums in closed loop two-phase thermosyphon: Thermal resistance and pressure [J].
Bai, Ye ;
Wang, Liang ;
Zhang, Shuang ;
Lin, Xipeng ;
Peng, Long ;
Chen, Haisheng .
APPLIED THERMAL ENGINEERING, 2020, 174
[2]   Numerical analysis of a closed loop two-phase thermosyphon under states of single-phase, two-phase and supercritical [J].
Bai, Ye ;
Wang, Liang ;
Zhang, Shuang ;
Lin, Xipeng ;
Chen, Haisheng .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 :354-367
[3]   Research on the refrigerant distribution and distinctive flow phenomena in a two-phase loop thermosyphon through a holistic visualization method [J].
Cao, Hanwen ;
Li, Haibin ;
Ding, Tao ;
He, Zhiguang ;
Li, Zhen .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 125 :64-74
[4]   Research on the refrigerant column height in the downcomer of a two-phase loop thermosyphon [J].
Cao, Hanwen ;
Ding, Tao ;
He, Zhiguang ;
Li, Zhen .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 94 :40-48
[5]   Experimental study on the temperature management behaviours of a controllable loop thermosyphon [J].
Cao, Jingyu ;
Chen, Chuxiong ;
Su, Yuehong ;
Leung, Michael K. H. ;
Bottarelli, Michele ;
Pei, Gang .
ENERGY CONVERSION AND MANAGEMENT, 2019, 195 :436-446
[6]   Performance evaluation of controllable separate heat pipes [J].
Cao, Jingyu ;
Li, Jing ;
Zhao, Pinghui ;
Jiao, Dongsheng ;
Li, Pengcheng ;
Hu, Mingke ;
Pei, Gang .
APPLIED THERMAL ENGINEERING, 2016, 100 :518-527
[7]   Sub-atmospheric boiling heat transfer and thermal performance of two-phase loop thermosyphon [J].
Chang, S. W. ;
Lo, D. C. ;
Chiang, K. F. ;
Lin, C. Y. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 39 :134-147
[8]   Experimental investigations and modeling of a loop thermosyphon for cooling with zero electrical consumption [J].
Chehade, Ali ;
Louahlia-Gualous, Hasna ;
Le Masson, Stephane ;
Lepinasse, Eric .
APPLIED THERMAL ENGINEERING, 2015, 87 :559-573
[9]   Long-term thermal performance of a two-phase thermosyphon solar water heater [J].
Chen, Bo-Ren ;
Chang, Yu-Wei ;
Lee, Wen-Shing ;
Chen, Sih-Li .
SOLAR ENERGY, 2009, 83 (07) :1048-1055
[10]   Characterisation of a controllable loop thermosyphon for precise temperature management [J].
Chen, Chuxiong ;
Cao, Jingyu ;
Yu, Jingjing ;
Liu, Weixin ;
Hu, Mingke ;
Wang, Qiliang ;
Jiao, Dongsheng ;
Ren, Wei ;
Pei, Gang .
APPLIED THERMAL ENGINEERING, 2021, 185